Universal Electronics H74426 User manual

Type
User manual
ZigbeePIRMotionSensorwithPetImmunity
H74426
InstallationInstructionsandUserManual
1. Specifications
Frequency:  2.4GHz(IEEE802.15.4)
OperatingTemperature: 32°113°F(0°45°C)
OperatingHumidity: 85%RHnoncondensing
Battery:  1xCR123APanasonicLithium3VDC
BatteryLife:  3Years
Compatibility:  Zigbee,
WWAH(WorkswithAllHubs)
PetImmunity:  Upto50lbs
CoverageArea:  40feetby40feet,90°angle
LightImmunity:  1500Lux
CoveragePattern:
SideView:

TopView:
 
2. PackageContents
1xSensor
4xScrews&WallAnchor1xCR123Abattery(installed)
2xSensorCaseScrew1xBackMounting2SidedAdhesiveTape
1xManual  2xSideMounting2SidedAdhesiveTape
3. ComponentIdentification
 
4. ZigbeeEnrollment:
ThisPIRMotionSensorneedstobepairedbeforeinstallation.
1. Pulltheexposedplasticbatterytab.
2. TheLEDwillblinkthreetimesevery23secondsinambercolorwhile
scanningthenetwork.
3. Ifnetworkisfoundandsuccessfullyjoined,theLEDwillbelitfor1secondin
ambercolorfollowedbyashortblinkingreencolor.
4. Ifnetworkisnotfoundafter1minute,thesensorwillgointosleepmode
andtheLEDwillblinkinambercolorevery1minute.Youneedtoresetthe
sensortotriggerapairingprocess,andthensensorwillrepeatstepsfrom2
to4.
Toresetthesensor:
1. Removethebatteryfor10seconds
2. Pressandholddownthetemperswitchwhilereinsertthebattery
3. Releasethetemperswitchwithin3seconds
5. Mounting
MountthePIRMotionSensorat7.5feet(2.3meters)abovethefloor.
Pressthecasereleasebuttontoseparatethefrontandbacksensorcase.
Thebackcasegivesaccesstoboththeflushmountandcornermount
screwknockouts.Drillthroughtheappropriateknockoutsandusethe
includedscrewstomountinthedesiredmountinglocation.
Itisrecommendedtoensurethereisatightsealaroundtheknockoutsto
preventbugsfromenteringthesensorandcausingfalsealarms.
Replacethefrontsensorcovertosnapshutandscrewinthesensorcase
screwsonthetopandbottomofthebacksensorcase.
6. WalkTestMode
Walktestmodecanbeusedtotestthemotionsensordetectioncoveragearea.
Toenterwalktestmode:
1. Removethebatteryfor10seconds
2. Pressandholddownthetamperbuttonwhilereinsertthebattery
3. Keepthetamperswitchholddownfor10secondsthenrelease
TheLEDwillbegintoblinkslowlyinambertoindicatesthemotionsensoris
warmingup.After45seconds,theLEDwillstopblinkingwhichindicatesthe
motionsensorisreadytodetectmotion.TheLEDwillbelitinredcolorto
illuminateeachtimemotionisdetected.OncetheLEDgoesout,thesensoris
readytodetectmotionagain.Walktestmodeendsafter20motionsdetected,
ornomotiondetectedfor1minutes.ItisrecommendedthatthePIRZB2ECOis
testedmonthlytoensureproperfunction.
7. Operation
ThePIRMotionSensorrequires45secondstowarmupforsignalstabilizing
whenperformingstartuporreset.Duringthewarmupperiod,theLEDwillblink
slowlyinamber.
Afterwarmupcompleted,theLEDwillblinkevery5minutesingreencolorto
indicatethesensorisworkingproperly.However,therearenoLEDindications
whenmotionisdetected.Thisisdonetomaximizebatterylife.Furthermore,
whenmotionisdetectedandasignalistransmittedtothepanel,thesensorwill
nottransmitagainuntiltherearenomotiondetectedforaperiodof3minutes
andmotionisdetectedagain.
8. Maintenance‐ReplacingtheBattery
Whenthebatteryislow,asignalwillbesenttothecontrolpanel.TheLEDwill
blinkevery2minutesinred.
Toinsertorreplacethebattery:
1. Pressthecasereleasebuttontoseparatethefrontandbacksensorcase
2. Removethefrontcasetoexposethebattery
3. ReplacetheCR123Alithiumbattery.Notethecorrectorientationofthe
batteryasshownonthebatterycompartment.
4. Replacethefrontcover.
WARNING:Failuretofollowthesewarningsandinstructionscanleadtoheat
generation,rupture,leakage,explosion,fire,orotherinjury,ordamage.Donot
insertthebatteryintothecompartmentinthewrongdirection.Alwaysreplace
thebatterywiththesameorequivalenttype(seeSpecificationsonsection1).
Neverrechargeordisassemblethebattery.Neverplacethebatteryinfireor
water.Alwayskeepbatteriesawayfromsmallchildren.Ifbatteriesare
swallowed,promptlyseeadoctor.
Alwaysdisposeand/orrecycleusedbatteriesinaccordancewiththehazardous
wasterecoveryandrecyclingregulationsforyourlocation.Yourcity,state,or
countrymayalsorequireyoutocomplywithadditionalhandling,recycling,and
disposalrequirements.
7.5 ft
03610131619232629333640
   (feet)
2926231916139630369131619232629
0
3
6
10
13
16
19
23
26
29
33
36
40
0
3
6
10
13
16
19
23
26
29
33
36
40
TamperSwitch
CR123ABattery
CaseReleaseButton
SensorCaseScrews
   (feet)
(feet)
9. `EnvironmentalandOtherUsefulInformation
5. WhilethePIRisahighlyreliableintrusiondetectiondevice,itdoesnotguaranteeagainst
burglary.Anyintrusiondeviceissubjecttoa“failuretowarn”foravarietyofreasons.
ConsiderthefollowingwheninstallingandsettingupthePIR:
6. ThisPIRhasbuiltinprotectiontokeepbugsfromgettingintothesensorareaandcausing
falsealarms.Notethatthisprotectiondoesnotpreventinsectsfromcrawlingacrossthelens
ofthePIR,whichcouldtriggerthePIR.
7. Infraredenergycanbereflectedoffanyglossysurfacessuchasmirrors,windows,floors,or
countertopswithglossyfinish,andslickfinishedconcrete.Somesurfacesreflectlessthan
others(e.g.thePIRcanseeachangeininfraredenergyoffofreflectivesurfacesevenifthe
heatorcoldsourceisnotwithinthePIRdetectionpattern).
8. Windowsreflectinfraredenergy.Theyalsoallowsunlightorlightfromothersources(e.g.,
cars)topassthroughtothePIR.ThePIRcandetectthesechangesininfraredenergy.For
example,ifsunlightpassingthroughawindowshinesontoahardwoodfloorandthechange
ininfraredenergyisquickenough,thePIRcantriggeranalarm.ThesameappliesifthePIR
areaincludesawindow,eventhoughthepatternofprotectioncannot“see”throughglass.
Lightsfromapassingcarcanalsopassthroughthewindowatnightandshinedirectlyintothe
PIR’slens.
9. Heatingandairconditioningductsarealsoimportantbecauseiftheyblowairontoanobject
withinthefieldofthePIR’sview,thetemperatureofthatobjectcouldchangequicklyenough
forthePIRto“see”achangeininfraredenergy.PIR’scannotseeaircurrent,onlythechange
intemperatureofaphysicalobject.
10. ThePIRsenseschangeintemperature.However,astheambienttemperatureofthe
protectedareaapproachesthetemperaturerangeof95°to120°F,thedetection
performanceofthePIRdecreases.
11. EnsurethattheareayouwishthePIRtocoverisfreeofobstructions(forexample,curtains,
screens,plants,andsoon.)thatmayblockthepatternofcoverage.
12. Anythingthatcanswayormoveduetoaircurrentcancauseachangeininfraredenergy
withinthefieldsofview.Draftsfromdoorsorwindowscancausethistohappen.Plants,
balloons,curtains,andhangingbasketsshouldneverbeleftinthePIR’sfieldofview.
13. DonotmountthePIRonasurfacethatallowsforanyvibration.Vibrationsnotonlycausethe
PIRtomovealittle,butitalsocausesthefieldsofviewinaroomtomovewithrespectthe
PIR.AlittlevibrationcancausehavocwiththePIR’sfieldofview,thusthePIRmayseea
changeinenergyandtriggerthealarm.
14. AninstallationoftenrequiresthatthePIRisaimedatthedoor.ThePIRmaydetectdoor
movementbeforethedoorcontactcaninitiateanentrydelay,causingthealarmtotrigger.If
youinstallthePIRfacingadoor,thenwhileprogrammingthePIR,chooseanappropriate
sensor/zonetype.
15. ThePIRONLYdetectsintrusionwithinthepatternofcoverage.
16. ThePIRdoesnotprovidevolumetricareaprotection.
17. ThePIRcreatesmultiplebeamsofprotection.Intrusioncanonlybedetectedinunobstructed
areascoveredbythosebeams.
18. ThePIRcannotdetectmotionorintrusionthatoccursbehindwalls,ceilings,floors,closed
doors,partitions,glassdoors,orwindows.
19. Tamperingwith,masking,painting,orsprayingofanymaterialonthePIRlensoranypartof
theopticalsystemcanimpairdetectionability.
20. ThePIR,likeotherelectricaldevices,aresubjecttocomponentfailure.EventhoughthePIRis
designedtolastaslongas10years,theelectroniccomponentsaresubjecttofailure.
FCCComplianceStatement
Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)This
devicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforClassBdigitaldevices,pursuanttoPart
15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencein
aresidentialinstallation.Thisequipmentgeneratesusesandcanradiateradiofrequencyenergyand,ifnot
installedandusedinaccordancewiththeinstructionmanual,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.If
thisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedby
turningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreof
thefollowingmeasures:
Reorientorrelocatethereceivingantenna
Increasetheseparationbetweentheequipmentandreceiver
Connecttheequipmenttoanoutletonadifferentcircuitfromthereceiver
Consultthedealeroranexperiencedradio/TVcontractorforhelp.
Theuseriscautionedthatchangesandmodificationsmadetotheequipmentwithouttheapprovalof
manufacturercouldvoidtheuser'sauthoritytooperatethisequipment.
FCCRadiationExposureStatement
ThisequipmentcomplieswithFCCRFradiationexposurelimitssentforthforanuncontrolledenvironment.This
equipmentshouldbeinstalledandoperatedwithaminimumdistanceof20centimetersbetweentheradiator
andyourbody.Theantennasusedforthistransmittermustbeinstalledtoprovideaseparationdistanceofat
least20cmfromallpersonsandmustnotbecolocatedoroperationinconjunctionwithanyotherantennaor
transmitter.
IndustryCanadarequirements
ThisdevicecomplieswithIndustryCanadalicenseexemptRSSstandard(s).Operationissubjecttothefollowing
twoconditions:(1)thisdevicemaynotcauseinterferenceand(2)thisdevicemustacceptanyinterference,
includinginterferencethatmaycauseundesiredoperationofthedevice
LepresentappareilestconformeauxCNRd'IndustrieCanadaapplicablesauxappareilsradioexemptsde
licence.L'exploitationestautoriséeauxdeuxconditionssuivantes:(1)l'appareilnedoitpasproduirede
brouillage,et(2)l'utilisateurdel'appareildoitacceptertoutbrouillageradioélectriquesubi,mêmesile
brouillageestsusceptibled'encompromettrelefonctionnement”
CanadaRFexposurecompliance
TocomplywithRSS102requirements,aseparationdistanceof20cmmustbekeptbetweenthedeviceandthe
useratalltimes.
PourseconformerauxexigencesRSS102,unedistancedeparationde20cmdoitêtremaintenueentre
l'appareiletl'utilisateuràtoutmoment.
FCCID:MG3H74426IC:2575AH74426
UniversalElectronicsInc.
PN:470070013520
REV&REVDate:A0301/28/2022
  • Page 1 1
  • Page 2 2

Universal Electronics H74426 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI