DocNo.FM0599issueDPage2
PetAlleyModeUP
TopreventpetscausingfalseactivationsthePIRdetector
mustbeinvertedandfittedatlowlevel(1m). PETALLEYORIENTATION
Whenfittedinthismodeanymovementbelow FITATLOWLEVELWITHLEDATTHETOP
the1mlevelwillgoun‐detected
.
Resultsbasedontestsina4mx4mroom.
WalkTestMode
Toenterthewalktestmode;
1. UndothescrewandremovethePIRlid
2. Waitforabout5seconds
3. Refitthelid
4. ThefrontredLEDwillflashrapidly8times
Younowhave3minutestoperformawalktest.
TheredLEDwillflashoncewhenmovementisdetected.
NOTE:therearenoradiotransmissionsduringawalktest.
AttheendofthewalktestperiodtheredLEDwill
flashrapidly8times.
ThePIRisnowinnormaloperatingmodeand
theLEDwillNOTflashwhenmovementisdetected.
Testing&RegisteringthePIRDetector
WhenthePIRlidisremovedthetamperswitchwilloperateandtransmitanalarmsignal.Thiswillalsocheckthebatterycondition
(andreportanalarmiflow)toassistServiceEngineers.
ThetamperswitchshouldbeactivatedwhenlearningthePIRontotheReachat‐homealarmorAdventxtwardencallsystem.
Seepages3&4forhowtoputeachoftheseproductsinto“LearnMode”.
Therangeofallradiodevicescanbeaffectedbytheworkingenvironment‐alwaystakecareduringinstallationand
performseveraltestcalls.
DILSwitchSettings
The2wayDILswitchinsidethePIRdetectorisusedtosetthesensitivityandalarminterval;
DILSwitchNo.&Function OFF(Default) ON
SW1=PulseCount(Sensitivity) 2pulsestotrigger 3pulsestotrigger
SW2=AlarmIntervalTime 3minutes 1minute
IffalsealarmsareaproblemtrysettingDILswitch1ONtoreducethesensitivity.
AfteranactivationthePIRturnsitselfoffforthealarmintervaltimetoconservebatterypower.
Duringthealarmintervalperiodmovementisnotdetected.
Maintenance
Noroutinemaintenanceisrequired;howeverawalktestshouldbeperformedonceayeartoverifyoperation.
PIR’sarenotassusceptibletodustandcontaminationassomedetectorsbutitisstillrecommendedtocleanthemperiodically.
PIR’scanbedustedorwipedcleanwithadampcloth,neverusedetergentsorpolish.
Decorating
NeverpaintthePIRdetectoritself.
Unlikesomedetectors,PIR’sarenotsusceptibletocontamination
frompaintfumesthereforenospecialprecautionsneedtobetaken.
BatteryLife
ThePIRcontains2longlifeLithiumbatteries. Undernormaloperatingconditions
(40activations/day)thebatteriesshouldlastforupto2years.
Thebatteryconditionischeckedonceaday,ifthevoltagefallsandstaysbelowa
presetlevelfor7consecutivedaysalowbatteryalertisautomaticallytransmitted.
Anotherlowbatterycallwillnotbetransmittedfor7days,thebatteriesshould
bereplacedwithin2weeksofthefirstlowbatterywarning.
Replacementbatteries:2xAAsizeEnergizerLithium–alwaysreplaceinpairs.
Takecaretorefitthebatteriesinthecorrectpolarity.
NORMALDETECTION
PATTERN‐SIDEVIEW
PETALLEYDETECTION
PATTERN‐SIDEVIEW
DETECTIONPATTERN
TOPVIEW