IS-49236-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
1) Take threaded pipe[A] from parts bag and screw in screw
collar loop[B] a minimum of 6 mm (1/4”). Lock into place
with hexnut[C].
2) Run another hexnut down threaded pipe almost touching
rst hexnut. Now screw threaded pipe into mounng
strap[D]. Mounng strap must be posioned with
extruded thread faced into outlet box[E]. Threaded pipe
must protrude out the back of mounng strap. Screw
third hexnut onto end of threaded pipe protruding from
back of mounng strap.
3) Connect mounng strap[D] to outlet box using the strap
mounng screws[J].
4) Unscrew the threaded ring[F] from screw collar loop. Take
canopy[G] and pass over screw collar loop. Approximately
one half of the screw collar loop exterior threads should
be exposed. Adjust screw collar loop by turning assembly
up or down in mounng strap. Remove canopy.
5) Aer desired posion is found, ghten both top and
boom hexnuts up against the boom and top of the
mounng strap.
6) Aach chain to xture[L] if required. Close the open link by
wrapping with a towel and squeezing closed using pliers.
7) Slip canopy over screw collar loop and thread on threaded
ring. Aach chain[H] (with xture connected) to boom of
screw collar loop. Unscrew threaded ring, let canopy and
threaded ring slip down.
8) Weave electrical wire and ground wire through chain[H]
no more than 3 inches apart. Pass wire through threaded
ring[F], canopy, screw collar loop, threaded pipe and into
outlet box.
9) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector aer following the above steps. Never connect
ground wire to black or white power supply wires.
10) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
11) Raise canopy to ceiling.
12) Secure canopy in place by ghtening threaded ring onto
screw collar loop.
13) Install the recommended bulb (not supplied).
14) Raise the glass cage assembly[I] up to the main body and
secure into place with the two (2) at head screws[K].
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Installaon Instrucons
[A] Threaded
Pipe
[B] Screw Collar
Loop
[C] Hexnut
[D] Mounting
Strap
[E] Outlet Box
[F] Threaded
Ring
[G] Canopy
[H] Chain
[I] Glass Cage
Assembly
[J] Strap
Mounting
Screws
[K] Flat Head
Screws
[L] Fixture
E
D
C
J
A
G
B
F
H
L
I
K