  • Hello! I am an AI chatbot trained to assist you with the Kichler Lighting 15515CBR User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
• Thispowersupplyisforusewithlandscapelightingsystemsonly.
• Donotsubmergetransformer.
• Thisdeviceisacceptedasacomponentofalandscapelightingsystem
wherethesuitabilityofthecombinationshallbedeterminedbyCSAor
localauthoritieshavingjurisdiction.TocomplywithCSArequirement,this
xtureshouldbeinstalledbyaqualiedelectrician.AuCanada.Pourêtre
enaccordavecIES1015CSA.Celuminairedoitêtreinstalléparun
électricienqualié.
• WARNING:Riskofelectricshock,useonlywithlowvoltagelandscape
xturesandaccessories.DOnotusewithswimmingpoolorspalighting
xtures.
• Donotconnecttwoormorepowersuppliesinparallel.
• Foroutdooruseonly.
• NationalElectricalCoderequiresthatwiringwhereconcealedorextended
throughabuildingwallmustbeenclosedinconduit.
• Transformershouldbemountedclosetopowersupply.Extensioncords
shouldnotbeusedwiththisunit.
• WARNING:(forPowerSupplyCordconnectedPOWERUNIT)
RISK OF ELECTRIC SHOCK.Installpowerunit5feet(1.5m)ormore
fromthepool,spa,orfountainwherethepowerunitisinstalled(a)
indoorwithin10feet(3.0m)ofapool,spa,orfountain,or(b)outdoor,
connectpowertounittoareceptacleprotectedbyaGFCI.
• Thisoutdoorpowerunitshallbeconnectedtoa115/120voltcoveredGFCI
receptaclemarked“WetLocation”whileinuse.
• Mounttherain-tighttransformeratleastonefootabovegroundlevelwith
thewireterminalsfacingdown.NOTE:Donotenergizetransformeruntil
installationofsystemiscomplete.
• Directburialratedwireistobeburiedaminimumof6”(152mm)beneath
thesurfaceoftheground.
NOTE:IfadditionalDirectBurialwireisneeded,contactyourlocal
Kichler
®
landscapedistributor.
•8GAwirecanbepurchasedinlengthof250’(76M),15503-BK.
•10GAwirecanbepurchasedinlengthof250’(76M),15504-BK.
•12GAwirecanbepurchasedinlengthsof100’(30M),15501-BK;250’
(76M),15502-BK;500’(152M),15505-BK;and1000’(304M),15506-BK.
• FindingTransformerLoad:Lowvoltagesystemsrequiretheuseofa
transformertoreducestandard120-VOLTpowerfromyourhometo
12-VOLTS.Todeterminethetransformersizeyouwillneed,addupthe
wattagesofalllampsyouplantouse.Selectatransformerthatmatches
ascloselyaspossibletothetotallampwattage.Forexample,ifyou
have11xturesallratedat24.4watts,youwillneeda300watt
(VA)transformer(11x24.4=268.4watts).Generally,thetotallampload
shouldnotbelessthanone-thirdthetransformerswattagerating,nor
exceeditsmaximumwattagecapacity.Ifyourtotalwattageistoohigh,
eitherdividetheloadbetweentwotransformers,oruseamorepowerful
transformer.
ThisinstructionsheetcoverstheinstallationofthefollowingKichler®Transformers:15515AZT,15M100AZT.Readtheseinstructionscarefully
beforeinstallingthisunit.
1) Determinedesiredlocationformountingtransformer.NOTE:When
decidinglocationformountingconsiderationshouldbetakenforthe
requirementslistedabove.
2) Markpositionoftopportionofthekeyholeslotlocationattopof
transformerandtheslotlocatedatbottom.
3) Ifmountingtoasolidsurfacesuchaswood,siding,etc;
 A) Drill1/8”diameterpilotholesatpositionsmarkedinStep2.
B) Drivescrewsapproximatelyhalfwayintoholes.
Ifmountingtodrywall:
A) Drill1/4”diameterholesatpositionsmarkedinStep2.
B) Pushplasticanchorsintoholesandtapuntilush.
C) Drivescrewsapproximatelyhalf-wayintoplasticanchors.
4) Sliplargeportionofkeyholeoverheadoftopscrewandallowtransformer
toslidedown,makingsurebottomslotisbehindheadofbottomscrew.
5) Tightenscrewsuntiltransformerissecure.
6) Split12/2.10/2,or8/2cableapproximately3”,andstrip1/2”insulation
offeachwire.12/2.10/2,and8/2cableistheheavyblackcablewhich
allKichler
®
12-voltlowvoltagelightingxtureswillbeconnected.
(Referenceabovefordescriptionandpartnumbers).
7) Pushonebarewireineachoftheholesonthebottomsideoftheterminal
blockandtightenscrewsonthefaceoftheterminalblockuntilwiresare
secure.
8) Plugpowersupplycordintostandard115/120voltreceptacle.NOTE:
Thepowersupplycordmustbepluggedintoaweathertightreceptacle
equippedwithaGroundFaultInterrupter(GFCI).
NOTE:Foroptimumlightoutputthevoltageatsocketshouldbebetween
10and12volts.
CIRCUIT BREAKER
(SECONDARYSIDE-12VOLTSIDE)
• Circuitbreakerwilltripifthereisashortoriftotal
wattageinstalledexceedsratedwattagepercircuit.
•Toresetbreaker,ipswitchto‘OFF’thenbackto
‘ON’position.
• Iftheunitcyclesonandoffwithoutregardtothe
timersetting,itshouldbecheckedbyaqualied
serviceperson.
THERMAL PROTECTION
(PRIMARYSIDE-120VOLTSIDE)
•Thisunitisequippedwithathermalprotectorand
willshutoffifoverheated.
INSTALLATION INSTRUCTIONS
DateIssued:8/14/09 IS-15515-US
WARRANTY
We Warrant our transformers for ten years on aZt units and lifetime on stainless steel units against defects in material and Workmanship if it is prop-
erly installed and failed under normal operating conditions, provided it is returned to the point of purchase, Where it Will be repaired or, as it may be
determined, to replace the transformer.
/