SINTHESI PANEL WITH DOOR UNIT AND DIGITISER
4
−−−−
sec.3a
DIGIVOICE - Technical Manual
Electric lock management criteria
Door lock release may be unrestricted or protected by privacy feature.
Operation will depend on the type of digitizer station as follows:
• Main station: If the door lock release is unrestricted, the digitizer
opens the door in response to commands received from any
decoder. If the door lock release is protected by privacy feature, the
digitizer will open the door only in response to commands received
from the doorphone branch with which a call is in progress.
• Secondary station: If the door lock release is unrestricted, the
digitizer opens the door in response to commands received from
any decoder on its riser cable. If the door lock release is protected
by privacy feature, the digitizer will open the door only in response
to commands received from the doorphone branch with which a call
is in progress.
The foregoing description does not apply to door lock release
commands received from the switchboard. In such cases, the
digitizer will open the door regardless of station type.
Door lock release time
The programmed door lock release time establishes the duration of
electric door lock relay activation. This time may be 0 to 30 seconds,
where 0 means that the relay is excited by a single pulse.
Ring duration
The length of time that a doorphone will ring (or the switchboard when
called by a main digitizer) will depend on how the calling digitizer is
programmed. Ring duration can be 1 to 5 seconds.
Number of voice lines
One or two independent voice lines may be physically present between
main and secondary digitizers. If there is only one line, the digitizer will
necessarily use this channel.
Buzzer volume setting
Volume of the digitizer signaling buzzer can be set to three levels: low
(not off), medium and high.
Call pushbutton programming
Each of the 104 pushbuttons that can be connected to the unit can
be associated with a user code between 0 and JJJJ, independently of
digitizer code and type.
Default programming
Default parameters for the device are as follows:
• DIGITIZER TYPE: MAIN
• DIGITIZER STATION CODE: JJJ
• ENGAGED TIME: 20 seconds
• ELECTRIC LOCK
MANAGEMENT CRITERION: PROTECTED BY
PRIVACY FEATURE
• DOOR LOCK RELEASE TIME: 0 seconds
• RING DURATION: 3 seconds
• NUMBER OF VOICE LINES: 1
• BUZZER VOLUME SETTING: MEDIUM
• DIGITIZER ID: “........... STREET”
• CALL PUSHBUTTONS: rrrr (private code)
PROGRAMMING WITH 1038/56 TERMINAL
Programming by means of the terminal must be performed with the
system on.
Terminalrmwarereleasemustbe2.0orhigher.
• Turn on the terminal, holding down the ‘ON’ key for at least 3
seconds.
• Plug the programming cord into the associated socket (1) or,
alternatively, into another entrance module, guard door switchboard
station or passive wiring block. The terminal will automatically be
connected to the data line, and the display will show the following
message for 3 seconds:
This will be followed by:
• Select the option <Serial Number>. The display will show:
Type in the digitizer serial number (shown on the rear label alongside
the designation S/N) and press ↵. The display will show:
At this point, the terminal is logically connected to the digitizer (DIG)
which has the selected serial number (‘uvwxyz’). The digitizer buzzer
will emit sequences of three beeps to indicate that the digitizer is in
‘Maintenance’ status.
NOTE: in ‘Maintenance’ status, the digitizer will continue to control
the electric lock when the lobby pushbutton or postal service
door lock release contact is actuated.
• Digitizer conguration parameters can now be programmed.
Parameters are shown on six pages:
(Page 1: Device detected (DIG) and Serial Number, neither of which
can be changed; address of installation site).
(Page 2: Type, Code, Engaged, Lock Management)
LOUDSPEAKING UNIT WITH INTEGRATED DIGITALIZER
Ref. 1038/7
PROGRAMMING
Programming
Search by:
<Serial Number>
<Type>
<Acquisition>
Serial Number:
000000
DIG SN:uvwxyz
---------------------------
Street ...........
DIG SN:uvwxyz
---------------------------
Street ...........
Type: P Cod:001
---------------------------
Engaged: 10 s
Lock rel.:S-00 s
LOUDSPEAKING UNIT WITH INTEGRATED DIGITALIZER
Ref.
1038/7