Fujitsu BX400 S1 User manual

Category
Servers
Type
User manual
Operating Manual - English
PRIMERGY BX400 S1
Blade Server Version
System Unit Operating Manual
May 2011
Comments Suggestions Corrections
The User Documentation Department would like to
know your opinion of this manual. Your feedback helps
us optimize our documentation to suit your individual
needs.
Feel free to send us your comments by e-mail to
Certified documentation
according to DIN EN ISO 9001:2008
To ensure a consistently high quality standard and
user-friendliness, this documentation was created to
meet the regulations of a quality management system
which complies with the requirements of the standard
DIN EN ISO 9001:2008.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademarks
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9240-003.fm
Copyright © 2009 Fujitsu Technology Solutions GmbH.
All rights reserved.Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trade names and/or trademarks of their respective
manufacturers.
The contents of this manual may be revised without prior notice.
Fujitsu assumes no liability for damages to third party copyrights or other rights arising from
the use of any information in this manual.
No part of this manual may be reproduced in any form without the prior written permission
of Fujitsu.
Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of
Microsoft Corporation in the USA and other countries.
Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries
in the USA and other countries.
BX400 S1 Operating Manual 3
Before reading this manual
For your safety
This manual contains important information for safely and correctly using this
product.
Carefully read the manual before using this product. Pay particular attention to
the accompanying manual "Safety Notes and Regulations" and ensure these
safety notes are understood before using the product. Keep this manual and the
manual "Safety Notes and Regulations" in a safe place for easy reference while
using this product.
Radio interference
This product is a "Class A" ITE (Information Technology Equipment). In a
domestic environment this product may cause radio interference, in which case
the user may be required to take appropriate measures. VCCI-A
Aluminum electrolytic capacitors
The aluminum electrolytic capacitors used in the product's printed circuit board
assemblies and in the mouse and keyboard are limited-life components. Use of
these components beyond their operating life may result in electrolyte leakage
or depletion, potentially causing emission of foul odor or smoke.
As a guideline, in a normal office environment (25°C) operating life is not
expected to be reached within the maintenance support period (5 years).
However, operating life may be reached more quickly if, for example, the
product is used in a hot environment. The customer shall bear the cost of
replacing replaceable components which have exceeded their operating life.
Note that these are only guidelines, and do not constitute a guarantee of
trouble-free operation during the maintenance support period.
High safety use
This product has been designed and manufactured for general uses such as
general office use, personal use, domestic use and normal industrial use. It has
not been designed or manufactured for uses which demand an extremely high
level of safety and carry a direct and serious risk to life or body if such safety
cannot be ensured.
4 Operating Manual BX400 S1
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9240-003.fm
These uses include control of nuclear reactions in nuclear power plants,
automatic airplane flight control, air traffic control, traffic control in mass
transport systems, medical devices for life support, and missile guidance
control in weapons systems (hereafter, "high safety use"). Customers should
not use this product for high safety use unless measures are in place for
ensuring the level of safety demanded of such use. Please consult the sales
staff of Fujitsu if intending to use this product for high safety use.
Measures against momentary voltage drop
This product may be affected by a momentary voltage drop in the power supply
caused by lightning. To prevent a momentary voltage drop, use of an AC
uninterruptible power supply is recommended.
(This notice follows the guidelines of Voltage Dip Immunity of Personal
Computer issued by JEITA, the Japan Electronics and Information Technology
Industries Association.)
Technology controlled by the Foreign Exchange and Foreign Trade
Control Law of Japan
Documents produced by Fujitsu may contain technology controlled by the
Foreign Exchange and Foreign Trade Control Law of Japan. Documents which
contain such technology should not be exported from Japan or transferred to
non-residents of Japan without first obtaining authorization in accordance with
the above law.
Harmonic Current Standards
This product conforms to harmonic current standard JIS C 61000-3-2.
Only for the Japanese market:
About SATA hard disk drives
The SATA version of this server supports hard disk drives with SATA / BC-SATA
storage interfaces. Please note that the usage and operation conditions differ
depending on the type of hard disk drive used.
Please refer to the following internet address for further information on the
usage and operation conditions of each available type of hard disk drive:
http://primeserver.fujitsu.com/primergy/harddisk/
BX400 S1 Operating Manual 5
Only for the Japanese market:
I Although described in this manual, some sections do not apply to the
Japanese market. These options and routines include:
CSS (Customer Self Service)
6 Operating Manual BX400 S1
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9240-003.fm
BX400 S1 Operating Manual 7
Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.1 Concept and target groups for this manual . . . . . . . . . 11
1.2 Documentation overview . . . . . . . . . . . . . . . . . . . 12
1.3 Performance features . . . . . . . . . . . . . . . . . . . . . 13
1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 19
1.5 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 20
2 Installation steps, overview . . . . . . . . . . . . . . . . . . 23
3 Important notes . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 25
3.2 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.3 Transporting the system unit . . . . . . . . . . . . . . . . . 33
3.4 Notes on installation into the rack . . . . . . . . . . . . . . 34
3.5 Environmental protection . . . . . . . . . . . . . . . . . . . 35
4 Installing the hardware . . . . . . . . . . . . . . . . . . . . . 37
4.1 Installation procedure . . . . . . . . . . . . . . . . . . . . . 38
4.2 Unpacking the system unit . . . . . . . . . . . . . . . . . . 38
4.3 Setting up the floorstand model . . . . . . . . . . . . . . . . 39
4.4 Installing/removing the rack model . . . . . . . . . . . . . . 40
4.4.1 Rack system requirements . . . . . . . . . . . . . . . . . . . 40
4.4.2 Installation in the rack . . . . . . . . . . . . . . . . . . . . . . 43
4.4.3 Installing/removing the system unit . . . . . . . . . . . . . . . 46
4.5 Connecting devices to the system unit . . . . . . . . . . . . 49
4.5.1 Cable routing . . . . . . . . . . . . . . . . . . . . . . . . . . 51
4.6 Connecting the system unit to the mains . . . . . . . . . . 51
8 Operating Manual BX400 S1
Contents
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9241-003.fm
4.6.1 Using cable ties . . . . . . . . . . . . . . . . . . . . . . . . . . 53
4.7 Instructions for connecting/disconnecting cables . . . . . . 54
5 Installation and operation . . . . . . . . . . . . . . . . . . . . 55
5.1 Control and display elements . . . . . . . . . . . . . . . . . 55
5.1.1 Front of system . . . . . . . . . . . . . . . . . . . . . . . . . . 55
5.1.1.1 Control elements . . . . . . . . . . . . . . . . . . . . . . . 58
5.1.1.2 LEDs on the control panel . . . . . . . . . . . . . . . . . . . 58
5.1.1.3 System ID card . . . . . . . . . . . . . . . . . . . . . . . . 60
5.1.2 Back of system . . . . . . . . . . . . . . . . . . . . . . . . . . 61
5.1.2.1 Control and display elements on the management blade . . . 61
5.1.2.2 Indicator on the hot-plug power supply units . . . . . . . . . 64
5.1.2.3 Indicators on the hot-plug fan modules . . . . . . . . . . . . 65
5.2 Switching the system unit on/off . . . . . . . . . . . . . . . . 66
5.3 Configuring management blades . . . . . . . . . . . . . . . . 68
5.4 Cleaning the system unit . . . . . . . . . . . . . . . . . . . . 73
6 Property and data protection . . . . . . . . . . . . . . . . . . 75
7 Troubleshooting and tips . . . . . . . . . . . . . . . . . . . . 77
7.1 System power indicator does not light up . . . . . . . . . . . 77
7.2 Front or back error LED flashes orange . . . . . . . . . . . . 78
7.3 System switches itself off . . . . . . . . . . . . . . . . . . . . 79
8 Hot-plug components . . . . . . . . . . . . . . . . . . . . . . 81
8.1 Server blades and storage blades . . . . . . . . . . . . . . . 82
8.2 Connection blades . . . . . . . . . . . . . . . . . . . . . . . 88
8.2.1 Connection Blade GbE Switch/IBP 36/12 (SB11A) . . . . . . . . 89
8.2.2 Connection Blade GbE Switch/IBP 36/8+2 (SB11) . . . . . . . . 91
8.2.2.1 Connection blade stacking . . . . . . . . . . . . . . . . . . 94
8.2.3 Connection Blade GbE Switch/IBP 18/6 (SB6) . . . . . . . . . . 95
8.2.4 Connection Blade 10 GbE Switch/IBP 18/8 . . . . . . . . . . . . 97
BX400 S1 Operating Manual 9
Contents
8.2.5 Connection Blade Ethernet Pass Thru 10Gb 18/18 . . . . . . . 99
8.2.6 Connection Blade 8Gb FC Switch 18/8 . . . . . . . . . . . . . 102
8.2.7 Connection Blade 8Gb FC Pass Thru 18/18 . . . . . . . . . . 104
8.2.8 Connection Blade Infiniband Switch 40 Gb 18/18 . . . . . . . 106
8.2.9 Fitting rules for connection blades . . . . . . . . . . . . . . . . 108
8.2.10 Port assignment of the connection blades . . . . . . . . . . . . 110
8.2.11 Installing a connection blade . . . . . . . . . . . . . . . . . . 112
8.3 Management blades . . . . . . . . . . . . . . . . . . . . . . 118
8.4 Hot-plug power supply units . . . . . . . . . . . . . . . . . 119
8.4.1 Replacing the power supply unit . . . . . . . . . . . . . . . . . 121
8.5 Hot-plug fan modules . . . . . . . . . . . . . . . . . . . . . 123
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
10 Operating Manual BX400 S1
Contents
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9241-003.fm
BX400 S1 Operating Manual 11
1 Introduction
The PRIMERGY BX400 S1 blade server is a highly compact, energy-saving
and scalable server system for installation in a 19-inch rack or as a floorstand
model. The BX400 S1 system unit offers 8 slots for a mixture of server blades
and storage blades (therein a maximum of 4 single-slot storage-blades
respectively 2 double-slot JBOD blades).
With its advanced infrastructure modules, the BX400 S1 system unit offers the
server blades a high level of connectivity and availability. These include hot-plug
connection blades, redundant management blades and power supply units, the
server management of the PRIMERGY ServerView suite, Prefailure Detection
and Analyzing (PDA), and Automatic Server Reconfiguration and Restart
(ASR&R).
Security functions in the BIOS-setup of the server blades and on the system
boards protect the data on the blade server from manipulation. Additional
security is provided by the lockable rack door.
The BX400 S1 system unit occupies 6 height units (HU) in the rack.
1.1 Concept and target groups for this manual
This operating manual describes how to install, set up and operate your server.
This operating manual is intended for those responsible for installing the
hardware and ensuring that the system runs smoothly. It contains all the
information you need to put your PRIMERGY BX400 S1 system unit into
operation.
To understand the various expansion options, you will need to be familiar with
the fields of hardware and data transmission and you will require a basic
knowledge of the underlying operating system.
12 Operating Manual BX400 S1
Introduction
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9242-003.fm
1.2 Documentation overview
More information on your PRIMERGY BX400 S1 system unit can be found in
the following documents:
"Quick Start Hardware - PRIMERGY BX400 S1" leaflet
" はじめにお読みください -PRIMERGY BX400 S1" for the Japanese market
(only included as a printed copy)
"Safety Notes and Regulations" manual
" 安全上のご注意 " for the Japanese market
"Warranty" manual
" 保証書 " for the Japanese market
"ServerView Suite Local Service Concept - LSC" manual
"Returning used devices" manual and "Service Desk" leaflet
" サポート&サービス " for the Japanese market
"PRIMERGY BX400 S1 System Unit Operating Manual"
"PRIMERGY BX400 S1 System Unit Options Guide"
I PRIMERGY manuals are available in PDF format on the
ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the
ServerView Suite supplied with every server.
If you no longer have the ServerView Suite DVDs, you can obtain the
relevant current versions using the order number U15000-C289 (the
order number for the Japanese market: please refer to the configurator
of the server http://primeserver.fujitsu.com/primergy/system/).
The PDF files of the manuals can also be downloaded free of charge
from the Internet. The overview page showing the online documentation
available on the Internet can be found using the URL (for EMEA market):
http://manuals.ts.fujitsu.com. The PRIMERGY server documentation can
be accessed using the Industry standard servers navigation option.
For the Japanese market please use the URL:
http://primeserver.fujitsu.com/primergy/manual/.
Further sources of information
Further information is provided:
The Deployment Manager manual (only relevant for cloning server blades)
BX400 S1 Operating Manual 13
Introduction
Documentation on the server blades and storage blades
The manual "PRIMERGY BX400 Blade Server Systems ServerView
Management Blade S1 User Interface Description"
1.3 Performance features
Customer Self Service (CSS)
The Fujitsu Technology Solutions Customer Self Service (CSS) concept
enables you to identify and replace the affected component yourself in the case
of certain error scenarios.
In the CSS concept, you can replace the following components yourself in the
event of an error:
Hot-plug hard disk drives
Hot-plug power supply units
Memory modules
System fan
Expansion cards
For information on replacing these components, see chapter "Hot-plug
components" on page 81.
CSS indicators on the control panel and on the back of the PRIMERGY server
provide you with information if a CSS event arises (for more information on the
behavior of these indicators, see chapter "Installation and operation" on
page 55 and the "ServerView Suite Local Service Concept - LSC" manual on
the ServerView Suite DVD 2).
Your system unit can fitted with a ServerView Local Service Display for Blade,
which enables you to identify the type of component affected by the error
directly on the server (for more information, see the "PRIMERGY
ServerView Suite Local Service Concept - LSC" manual on the PRIMERGY
ServerView Suite DVD 2).
In addition, CSS errors are displayed in the ServerView Operations Manager -
the server management software from Fujitsu Technology Solutions.
14 Operating Manual BX400 S1
Introduction
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9242-003.fm
In the event of errors, the ServerView Operations Manager refers you directly
to the affected component and its order information in the Illustrated Spares
catalog of the server in question. (This feature is not available for the Japanese
market.)
Server performance
The system unit has 8 slots for server blades. Four server blade slots can be
fitted with storage blades (or six slots with JBODs) which provide additional
storage capacity for the neighboring server blades. For information on installing
and removing server blades and storage blades, see section "Server blades
and storage blades" on page 82. For further information on the server blades
and storage blades, see the relevant operating manuals.
Connection blades
The PRIMERGY BX400 S1 system unit has four slots for connection blades on
the back. These provide the installed server blades with connections to the
Ethernet LAN as well as to SAN environments and Infiniband environments.
The following connection blade types are available:
Ethernet connection blades
Connection Blade GbE Switch/IBP 36/12 (SB11A)
36 internal 1-Gbit ports to the server blades
8 external 1-Gbit ports through RJ45 connections
4 external 1-Gbit ports through SFP modules
I This connection blade can be used in all connection blade slots.
Connection Blade GbE Switch/IBP 36/8+2 (SB11)
36 internal 1-Gbit ports to the server blades
8 external 1-Gbit ports through RJ45 connections
2 external 10-Gbit ports through SFP+ modules
1 internal stacking port to the midplane of the BX400 S1 system unit
1 external stacking port through a CX4 connection
The stacking ports allow up to 4 SB11 connection blades to be
switched together to form a so-called stack, see "Connection blade
stacking" on page 94.
I This connection blade can be used in connection blade slots.
BX400 S1 Operating Manual 15
Introduction
Connection Blade 1GbE Switch/IBP 18/6 (SB 6)
18 internal 1-Gbit ports to the server blades
6 external 1-Gbit ports through SFP+ modules or active twinax
cables (copper)
I This connection blade can be used in all connection blade slots.
Connection Blade 10 GbE Switch/IBP 18/8
18 internal 10-Gbit ports to the server blades
8 external 10-Gbit ports through SFP+ modules or active twinax
cables (copper)
I This connection blade can be used in all connection blade slots.
10 GbE connection blades in slots CB2 (fabric 2) and CB3/4
(fabric 3) only support server blades that are fitted with a 10 Gbit
Ethernet mezzanine card (see also section "Fitting rules for
connection blades" on page 108).
Connection Blade Ethernet Pass Thru 10Gb 18/18
18 internal 1/10-Gbit ports to the server blades
18 external 1/10-Gbit ports through SFP/SFP+ modules
I This connection blade can be used in all connection blade slots.
If the connection blade is installed in one of the slots CB 1 or CB
2, 16 ports are available. If the connection blade is installed in one
of the slots CB 3 or CB 4, 8 ports are available (see also "Port
assignment" on page 101).
Fiber Channel connection blades
Connection Blade 8Gb FC Switch 18/8
18 internal 8-Gbit ports to the server blades
8 external ports through 8-Gb SFP+ modules or 4-Gb SFP modules
This connection blade is available in three license variants:
Brocade 5450 with 14-port license
Brocade 5450 with 26-port license (applies only to EMEA market)
Brocade 5450 with 26 port license and performance bundle (applies
only to EMEA market)
16 Operating Manual BX400 S1
Introduction
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9242-003.fm
Connection Blade 8Gb FC Pass Thru18/18
18 internal 8-Gbit ports to the server blades
18 external ports through 8-Gb SFP+ modules or 4-Gb SFP modules
I Fibre Channel connection blades can only be installed in slots CB3/4
(fabric 3)and only support server blades that are fitted with a Fibre
Channel mezzanine card.
Infiniband connection blade
Connection Blade Infiniband Switch 40 Gb 18/18
18 internal 40-Gbit Infiniband ports to the server blades
18 external 40-Gbit Infiniband connections through QSFP modules
I Infiniband connection blades can only be used in the slots CB 3/4,
see figure "Connection blade slots" on page 108. They only support
server blades that are fitted with an Infiniband mezzanine card.
The connection blades support hot-swapping. By installing two connection
blades in two adjacent slots (not possible with Infiniband connection blades),
you can provide redundant network connections for the server blades (for
details, see section "Connection blades" on page 88).
Management blade
The system unit has slots for two redundant, hot-swap management blades with
an integrated management solution for complete remote administration of the
system. The base configuration of the system unit contains one management
blade (for details, see section "Management blades" on page 118).
Power supply
The system unit has four installation bays for hot-plug power supply units which
automatically set themselves to a voltage in the range of 100 - 240 V. The base
configuration includes one power supply unit. As an option, you can set up a
redundant power supply with up to three additional power supply units. If a
power supply unit fails, the redundant configuration assures continued
operation. The defective power supply unit can be replaced during operation
(for further details see section "Hot-plug power supply units" on page 119).
BX400 S1 Operating Manual 17
Introduction
Cooling
Cooling of the system is ensured by two fans in each power supply unit and by
the fan modules. Each of the fan units contains 2 fans. The fan modules have
the same aspect ratio as the power supply units. Empty power supply
installation bays must be fitted with fan modules. The configuration is redundant
and offers hot-swap functionality (for more information, see "Hot-plug power
supply units" on page 119).
High level of availability and failure protection
ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in
the event of an error and automatically "hides" the defective system
components.
The PDA (Prefailure Detection and Analyzing) technology from Fujitsu
Technology Solutions analyzes and monitors all components that are critical for
system reliability.
The hot-swap components provide additional failure protection. Failure
protection for the entire system is ensured by four redundant hot-swap power
supply units as well as redundant hot-swap fans.
Server management
Server management is implemented using the ServerView Operations Manager
supplied and the PDA (Prefailure Detection and Analysis) technology from
Fujitsu. PDA reports the threat of a system error or overload at an early stage,
allowing preventive measures to be taken.
The ServerView Operations Manager enables the management of all
PRIMERGY servers in the network via a central console. The ServerView
Operations Manager supports the following functions:
Round-the-clock monitoring, regardless of server status
High-performance, graphical console bypass (AVR) protected by
HTTPS/SSL (128 bit)
Remote storage via USB
Remote power on
Temperature monitoring of the CPU and the surrounding area
Detailed status and error reports for processors and main memory
18 Operating Manual BX400 S1
Introduction
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9242-003.fm
Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R)
in the event that memory modules or processors fail
Power monitoring
End-of-life monitoring of fans with prompt notification before failure
Watchdog timer for monitoring the operating system with ASR&R
Further information on the ServerView Operations Manager is provided in the
associated documentation.
Service and support
PRIMERGY servers are easy to maintain and modular, thus enabling quick and
simple maintenance.
The handles and locks (touch points) on the various hot pluggable components
are colored green to ensure simple and immediate recognition.
In order to prevent the components from being damaged by incorrect handling
when they are being installed and removed, the areas of all components that
can be touched without damaging them are also marked green.
The redundant management blades and the optional remote test and
diagnostics system ServerView Remote Management allows the PRIMERGY
BX400 S1 blade servers to be serviced from a remote system. This enables
remote diagnosis for system analysis, remote configuration and remote restart
should the operating system or hardware fail.
BX400 S1 Operating Manual 19
Introduction
1.4 Notational conventions
The following notational conventions are used in this manual:
Text in italics indicates commands or menu items.
"Quotation marks" indicate names of chapters and terms that are being
emphasized.
Ê describes activities that must be performed in the order
shown.
V CAUTION! pay particular attention to texts marked with this symbol.
Failure to observe this warning may endanger your life,
destroy the system or lead to the loss of data.
I indicates additional information, notes and tips.
20 Operating Manual BX400 S1
Introduction
© cognitas. Gesellschft für Technik-Dokumentation mbH 2009 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-9242-003.fm
1.5 Technical data
Electrical data (hot-plug power supply unit)
Compliance with regulations and standards
Rated voltage range 100 - 240 V
Frequency 50 Hz-60 Hz
Max. rated current 45 A / 22.5 A (100-240 V)
Effective power 1785 W (240 V) 1200 W (100 V)
Apparent power 1821 VA (240 V) 1265 VA (100 V)
Heat dissipation 11520 kJ/h (with 3200 W) 5760 kJ/h
(with1600 W)
Main power fuse 16 A
Protection class I
Product safety and
ergonomics
IEC 60950-1 / EN 60950-1, UL/CSA 60950-1 (all
second edition is acquired)
CNS 14336 / GB 4943 / EN 50371
Electromagnetic
compatibility
GB 17625
interference
emissions
EN 55022 class A
Harmonic current EN 61000-3-2
Flicker EN 61000-3-3
interference
immunity
EN 55024, EN 300386
to EU directives Electromagnetic compatibility 2004/108/EC
Mechanical
environmental
conditions
EN 60721-3-3; class 3M2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130

Fujitsu BX400 S1 User manual

Category
Servers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI