Fujitsu Siemens Computers FibreCAT SX40 Service Supplement Manual

  • Hello! I am an AI chatbot trained to assist you with the Fujitsu Siemens Computers FibreCAT SX40 Service Supplement Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PRIMERGY
FibreCAT® SX40
Storage Subsystem
Service Supplement
Joachim Pichol
Fujitsu Siemens Computers GmbH Paderborn
33094 Paderborn
e-mail: email: [email protected]
Tel.: (05251) 8-14884
Fax: (++49) 700 / 372 00001
FibreCAT SX40
Sprachen: En
Edition February 2007
CommentsSuggestionsCorrections
The User Documentation Department would like to
know your opinion of this manual. Your feedback helps
us optimize our documentation to suit your individual
needs.
Feel free to send us your comments by e-mail to
Certified documentation
according to DIN EN ISO 9001:2000
To ensure a consistently high quality standard and
user-friendliness, this documentation was created to
meet the regulations of a quality management system
which complies with the requirements of the standard
DIN EN ISO 9001:2000.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademarks
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: D:\Aktuelles_Projekt\PRIMERGY\SX40\Suppl\EN\SX40_ss_us.vor
Copyright © 2007 Fujitsu Siemens Computers GmbH.
All rights reserved.
Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.
FibreCAT SX40 Service Supplement
Contents
1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Documentation overview . . . . . . . . . . . . . . . . . . . . 5
1.2 Notational conventions . . . . . . . . . . . . . . . . . . . . . 7
2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3 Important notes . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.1 Notes on safety . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.2 ESD label . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.3 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.4 RFI suppression . . . . . . . . . . . . . . . . . . . . . . . . 14
3.5 Notes on the rack model . . . . . . . . . . . . . . . . . . . . 14
3.6 Environmental protection . . . . . . . . . . . . . . . . . . . 15
4 Replacing components . . . . . . . . . . . . . . . . . . . . 17
4.1 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.2 Replacing the I/O module . . . . . . . . . . . . . . . . . . . 18
4.3 Replacing LED displays . . . . . . . . . . . . . . . . . . . . 19
4.4 Replacing the midplane . . . . . . . . . . . . . . . . . . . . 19
4.5 Replacing the housing . . . . . . . . . . . . . . . . . . . . . 20
5 Cable overview . . . . . . . . . . . . . . . . . . . . . . . . . 21
Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: D:\Aktuelles_Projekt\PRIMERGY\SX40\Suppl\EN\SX40_ss_us.ivz
FibreCAT SX40 Service Supplement 5
1 Preface
The FibreCAT® SX40 storage subsystem is a passive system that can be
directly attached for data management or for expanding the hard disk capacity
of connected PRIMERGY servers.
With 2 height units (HU), the FibreCAT SX40 satisfies the requirements of both
compactness and maximum hard disk capacity in 19-inch rack infrastructures.
1.1 Documentation overview
Concept and target groups
This Service Supplement supplements the information contained in the
operating manual.
VATTENTION!
The activities described in this manual may only be performed by
specialist personnel with technical training.
IThe installation and removal of the hot-plug components is described in
the operating manual supplied with the storage subsystem.
Service DVD
A PRIMERGY service DVD is available for Fujitsu Siemens service partners.
This DVD contains the following manuals as PDF files:
The manual "Safety notes and other important information"
The operating manual for the PRIMERGY FibreCAT SX40
The Service Supplement for the PRIMERGY FibreCAT SX40
6 Service Supplement FibreCAT SX40
Documentation overview Preface
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: D:\Aktuelles_Projekt\PRIMERGY\SX40\Suppl\EN\SX40_ss_us.k01
Information/Activity Manual
Features and technical data of the storage
subsystem
Operating manual
Installation and activation, including:
External connections to the storage
subsystem
– Operation
Configuration of the storage subsystem
Installation of the rack mounting kit
Troubleshooting
Installation/removal of all hot-plug components,
such as:
Hot-plug power supply units
Hot-plug HDD modules
Replacing components:
Replacing I/O modules
Replacing LED displays
Replacing the midplane
Replacing the housing
Service Supplement
Cable overview
Detailed safety information manual "Safety notes and
other important information"
Table 1: Overview of the documentation
FibreCAT SX40 Service Supplement 7
Preface Notational conventions
1.2 Notational conventions
The following notational conventions are used in this manual:
Italics indicate commands, menu items or software programs.
“Quotation marks” indicate names of chapters and terms that need to be
emphasized.
Êindicates an activity that must be performed.
VATTENTION! indicates that, if you ignore the information given at this
point, your health, the correct functioning of your
system or the security of your data may be at risk.
Iindicates supplementary information, remarks and tips.
Table 2: Notational conventions
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: D:\Aktuelles_Projekt\PRIMERGY\SX40\Suppl\EN\SX40_ss_us.k01
FibreCAT SX40 Service Supplement 9
2Procedure
VATTENTION!
The activities described in this manual should only be performed by
engineers, service personnel or technical specialists.
ÊFirst of all please familiarize yourself with the safety instructions in the
chapter “Important notes” on page 11ff.
ÊMake sure that all the manuals you need (see service DVD) are available,
printing out the PDF files if necessary. You will definitely need the operating
manual for the storage subsystem.
ÊShut down the server connected to the storage subsystem correctly (see the
operating manual for the relevant server).
ÊSwitch off the storage subsystem, pull out the power plugs and – if
necessary – also disconnect the cables of the I/O modules as described in
the chapter “Replacing components” on page 17ff.
ÊReplace the defective component as described in the relevant chapter.
ÊIf necessary, reconnect the cables of the I/O modules to the storage
subsystem.1
ÊPlug the power plugs into the grounded power outlets1.
ÊSwitch on the storage subsystem.1
1These procedures are described in the operating manual.
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: D:\Aktuelles_Projekt\PRIMERGY\SX40\Suppl\EN\SX40_ss_us.k02
FibreCAT SX40 Service Supplement 11
3 Important notes
3.1 Notes on safety
This chapter provides safety instructions which you must observe when
handling your storage subsystem.
The device complies with the relevant safety regulations for data processing
equipment.
IThe following safety instructions can also be found in the manual entitled
“Safety notes and other important information”. Please also read the
notes in the operating manual for the attached PRIMERGY / PRIME-
QUEST system.
If you have any questions on setting up and operating the device in your
particular environment, please contact your sales outlet or our customer service
center.
VATTENTION!
The activities described in this manual may only be performed by
specialist technical personnel. Equipment repairs must only be
performed by service staff. Any unauthorized opening or improper
repairs could endanger the user (through electric shock, energy
hazard, fire hazard) or damage the equipment. Please note that any
unauthorized opening of the device will result in the invalidation of the
warranty and exclusion from all liability.
Transport the device only in its original packaging or in packaging
which protects it from knocks and jolts.
If the device is brought in from a cold environment, condensation may
form both inside and on the outside of the machine. Before operating
the device, wait until it is dry and has reached approximately the
same temperature as the installation site. Failure to observe these
guidelines can lead to material damage of the device.
Check that the rated voltage specified on the device's ID plate is the
same as the local mains voltage.
Only connect the device to a properly grounded wall outlet (the device
is fitted with a tested and approved power cable).
12 Service Supplement FibreCAT SX40
Notes on safety Important notes
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: D:\Aktuelles_Projekt\PRIMERGY\SX40\Suppl\EN\SX40_ss_us.k03
VATTENTION!
Make sure that the sockets on the device and the power points used
are freely accessible.
Switching off the device does not disconnect it from the mains. To
completely disconnect it from the mains voltage, you must remove the
power plugs from the power outlet.
Before opening the device, switch it off first, then pull out the power
plug.
Route the cables in such a way that they do not form a potential
hazard (tripping) and cannot be damaged. When connecting a
device, refer to the relevant notes in the appropriate operating
manual.
Do not connect or disconnect any data transmission cables during a
thunderstorm (lightning hazard).
Systems which comprise a number of cabinets must use a separate
fused socket for each cabinet.
Always connect the server and the directly connected external
storage subsystems to the same power supply distributor. Otherwise
you run the risk of losing data if, for example, the central unit is still
running but the storage subsystem has failed during a power cut.
Make sure that no objects (such as bracelets or paper clips) fall into
or liquids spill into the device (risk of electric shock or short circuit).
In emergencies (e.g. damaged casing, control elements or cable,
penetration of liquids or foreign bodies), switch off the device immedi-
ately, unplug it from the mains, and contact your customer service
center.
Note that proper operation of the system (in accordance with IEC
60950-1/EN 60950-1) is only guaranteed if slot covers are installed in
all vacant slots and/or dummies in all vacant bays and the housing
cover is fitted (cooling, fire protection, RFI suppression).
FibreCAT SX40 Service Supplement 13
Important notes ESD label
3.2 ESD label
Components which can be damaged by electrostatic discharge (ESDs, electro-
static-sensitive devices) may have the following label:
Figure 1: ESD label
When handling modules with ESDs, it is essential that you observe the following
guidelines:
ÊYou must electrostatically discharge yourself (e.g. by touching a grounded
object) before handling modules with ESDs.
ÊAny devices or tools that are used must be free of electrostatic charge.
ÊPull out the power plug before installing or uninstalling modules containing
electrostatic-sensitive components.
ÊTouch modules containing electrostatic-sensitive components only at the
edges.
ÊDo not touch any connectors or conduction paths on a module containing
electrostatic-sensitive components.
ÊWhile installing modules, wear a suitable grounding strap that connects you
to the system unit.
ÊPlace all the components on a pad which is free of electrostatic charge.
IFor a detailed description of how to handle ESD-module components,
see the relevant European or international standards (EN 61340-5-1,
ANSI/ESD S20.20).
14 Service Supplement FibreCAT SX40
CE conformity Important notes
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: D:\Aktuelles_Projekt\PRIMERGY\SX40\Suppl\EN\SX40_ss_us.k03
3.3 CE conformity
3.4 RFI suppression
All other equipment which is connected to this product must also have radio
noise suppression in accordance with EC directive 89/336/EEC.
Products which meet this requirement are accompanied by a certificate to that
effect issued by the manufacturer and/or bear the CE mark. Products which do
not meet this requirement may be operated only with the special permission of
the German Federal Approvals Office for Telecommunications (BZT).
IThis is "Class A" equipment. This equipment may cause harmful inter-
ference in residential areas. In this case, the user may be required to take
appropriate measures and bear the costs resulting from these measures.
3.5 Notes on the rack model
For safety reasons, at least two people are required to install the rack model
because of its weight and size.
When connecting and disconnecting the cables, observe the notes in the
operating manual for your PRIMERGY/PRIMEQUEST system and the
chapter “Important notes” in the technical manual for the relevant rack. The
technical manual for the rack is supplied with the rack.
Ensure that the anti-tilt bracket is correctly mounted when you set up the
rack.
For safety reasons, no more than one unit may be pulled out of the rack at
any one time during installation and maintenance work.
If more than one unit is pulled out at any one time, the rack may tip over.
The rack must be connected to the mains by an authorized specialist
(electrician).
The device complies with the requirements of EC directive
89/336/EEC on “Electromagnetic Compatibility" and 73/23/EEC
“Low-Voltage Directive". This is indicated by the CE certificate
label (CE = Communauté Européenne) on the back of the device.
FibreCAT SX40 Service Supplement 15
Important notes Environmental protection
3.6 Environmental protection
Environmentally friendly product design and development
This product was designed in compliance with the Fujitsu Siemens Computers
standard on ”environmentally friendly product design and development”. This
means that the designers have taken into account important criteria such as
durability, selection of materials, emissions, packaging, the ease with which the
product can be dismantled, and the extent to which it can be recycled.This
saves resources and helps to protect the environment.
Notes on packaging
Do not throw away the packaging as you may need it for future transport. If
possible, devices should be transported in their original packaging.
Notes on labeling plastic housing parts
Avoid sticking your own labels on plastic housing parts whenever possible, as
this makes recycling more difficult.
Take-back, recycling and disposal
For details on take-back and reuse of devices and consumables within Europe,
see the manual "Returning used devices" or contact your Fujitsu Siemens
Computers branch office/subsidiary or our recycling center in Paderborn,
Germany:
Fujitsu Siemens Computers
Recycling Center
33106 Paderborn, Germany
Tel. +49 5251 8180-10
Fax +49 5251 8180-15
The device must not be disposed of together with regular
household refuse. This device is labeled according to European
directive 2002/96/EC on Waste from Electrical and Electronic
Equipment - WEEE).
This directive sets the framework for EC-wide take-back and
recycling of used devices. To return your device, please use the
return or collection systems available to you. For more infor-
mation see www.fujitsu-siemens.com/recycling.
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: D:\Aktuelles_Projekt\PRIMERGY\SX40\Suppl\EN\SX40_ss_us.k03
FibreCAT SX40 Service Supplement 17
4 Replacing components
VATTENTION!
When handling systems and boards, make sure you observe the safety
information in the chapter “Important notes” on page 11ff.
4.1 Preparation
To replace components which are not hot-pluggable, proceed as follows:
ÊShut down the server connected to the FibreCAT® SX40 storage subsystem;
wait until the server is switched off and then switch off both power supply
units of the storage subsystem.
ÊUnplug the two power plugs of the storage subsystem from the mains.
ÊDisconnect the SAS cables from the I/O modules.
18 Service Supplement FibreCAT SX40
Replacing the I/O module Replacing components
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: D:\Aktuelles_Projekt\PRIMERGY\SX40\Suppl\EN\SX40_ss_us.k04
4.2 Replacing the I/O module
Requirements
The storage subsystem has been switched off (see page 17)
The power cables have been uplugged.
The SAS cables have been removed.
Figure 2: Removing the I/O module
ÊUndo the two knurled screws (1) and pull the levers downward (2). This
moves the I/O module a little out of the device.
ÊTake the I/O module out of the bay.
To install the I/O module follow the above steps in reverse.
Product-no.: SNP:A3C40081244
2
1
1
2
FibreCAT SX40 Service Supplement 19
Replacing components Replacing LED displays
4.3 Replacing LED displays
IIn the case of defective LED displays, you replace the entire housing (see
section “Replacing the housing” on page 20).
4.4 Replacing the midplane
IIn the case of a defective midplane, you replace the entire housing (see
section “Replacing the housing” on page 20).
Product-no.: see 4.5 (housing)
Product-no.: see 4.5 (housing)
20 Service Supplement FibreCAT SX40
Replacing the housing Replacing components
© cognitas. Gesellschft für Technik-Dokumentation mbH 2007 Pfad: D:\Aktuelles_Projekt\PRIMERGY\SX40\Suppl\EN\SX40_ss_us.k04
4.5 Replacing the housing
VCAUTION!
Before you exchange the defective housing, the FRU data of the
ID-PROM must be exported with the SX40 FRU-Data Recovery Tool.
Once you have exchanged the housing, this data must be imported into
the ID-PROM of the new housing with the same tool. If the ID-PROM of
the defective housing is no longer readable, the FRU data for the new
housing can also be generated via an input mask with the SX40 FRU-Data
Recovery Tool.
Requirements
The storage subsystem has been switched off (see page 17).
The power cables have been uplugged.
All other cables connected to the storage subsystem have been removed.
All HDD modules have been removed (these must be removed before the
system is removed from the rack cabinet; the relevant procedure is
described in the operating manual).
The storage subsystem has been removed from the rack cabinet (see
operating manual).
Figure 3: Empty replacement housing for the storage subsystem
Product-no.: SNP:A3C40081243
/