Golden Lighting 7041-3 BLK-CLR Operating instructions

Type
Operating instructions
Assembly Instructions: 7041-3 (Monroe)
IMPORTANT:
• ALL INSTALLATION WORK SHOULD BE DONE BY ACCREDITED PROFESSIONAL.
• SHUT OFF POWER SUPPLY AT FUSE OR CIRCUIT BREAKER!
• USE ONLY THE SPECIFIED BULBS. DO NOT EXCEED THE MAXIMUM WATTAGE!
For Customer Service, please
contact the place of purchase.
House Wires
Fixture Wires
Hot
How to Identify the Fixture’s Wires
Hot Neutral Ground
Smooth
Ribbed
Bare Metal,
Green, or
Green Inner
Thread
Black
White
Black Inner
Thread
White Inner
Thread
PREPARING FOR INSTALLATION
Remove all of the contents from the carton. See the important notes above.
Shut off the power at the circuit breaker and completely remove the old
xturefromtheceiling,includingtheoldmountingstrap.
1.Mountingstrap(B)containsseveralpairsofthreadedholesandmay
havetwoofmountingscrews(D)attached.Ifso,youmayneedtotighten
hexnuts(C)thatholdthescrewsinplace.Ifmountingstrap(B)doesnot
havemountingscrews(A)attached,pleasendthescrewsandhexnuts
youremovedfromcanopy(S)andattachtothemountingstrapusinghex
nuts (C).
2.Placemountingstrap(B)uptoyourjunctionbox.Placecanopy(S)over
themountingstrapliningupmountingscrews(D)withtheholesincanopy
(S).Securemountingstrap(B)tothejunctionboxwithmountingscrews(A)
andascrewdriver.Tightenthescrewssecurely.
3.Oneofconnectorrods(N)hasthexture’swiresinside.Hookconnector
rods(N)totheframeatloops(Q)andthenpullthexturewiresuntiltaut.
Attach the top of connector rods (N) to canopy (S) at loops (R).
CONNECTING THE WIRES
4.Haveanassistantsupportthextureweightwhilecompletingthewiring.
Cutawayexcesswire.Attachthexture’swirestothepowersupplywires
fromthejunctionbox.Connectblacktoblack(orsmooth);whitetowhite
(orribbed);groundtoground(greenorcopper).Twisttheendsofthewire
pairstogether,thentwistonawireconnector.Makesurealltwistsarein
thesamedirection.Ifthereisnogroundwire(greenorcopper)fromthe
junctionbox,locategroundscrew(E)onmountingstrap(B)andwrapthe
xturegroundwirearoundthegreengroundscrew(E).Useascrewdriver
tosecuregroundscrew(E)ontothemountingbracket.Tuckallwiresneatly
intothejunctionbox.
Please note that the xture may be hung as a
pendant or a ushmount, please decide how
you would like the xture to be installed and
refer to the related instructions.
FINISHING THE INSTALLATION
5.Raisecanopy(S)totheceiling.Positionmountingscrews(A)sothattheyprotrudethroughtheopeningsofcanopy(S).
6.Securecanopy(S)tomountingstrap(B)withdecorativenuts(F).
7.Slideglassshades(P)oversockets(M)andsecureinplacewithsocketcovers(O).
8.
Installlightbulbs(notprovided)inaccordancewiththexture’sspecications.Donotexceedthemaximumrecommended
wattage.
Yourinstallationiscomplete.Turnonthepowerandtestthexture.
FLUSH INSTALLATION
CLEANING TIPS
Treat the xture gently! Regular cleaning will reduce the need for deep cleaning. For regular cleaning, turn off the light and wipe down the
xture with a clean lint-free cotton or microber cloth. Never spray cleaner directly onto the xture.
Please note that mounting
strap (B) is used in this
installation option. In this
conguration, canopy
(S) attaches directly to
mounting strap (B). do not
use top loop (L - please
ip the page and review
the diagram for more
information).
Q
N
M
O
P
R
F
D
C
B
A
E
S
Assembly Instructions: 7041-3 (Monroe)
IMPORTANT:
• ALL INSTALLATION WORK SHOULD BE DONE BY ACCREDITED PROFESSIONAL.
• SHUT OFF POWER SUPPLY AT FUSE OR CIRCUIT BREAKER!
• USE ONLY THE SPECIFIED BULBS. DO NOT EXCEED THE MAXIMUM WATTAGE!
House Wires
Fixture Wires
Hot
How to Identify the Fixture’s Wires
Hot Neutral Ground
Smooth
Ribbed
Bare Metal,
Green, or
Green Inner
Thread
Black
White
Black Inner
Thread
White Inner
Thread
PENDANT INSTALLATION - PREPARING FOR
INSTALLATION
Remove all of the contents from the carton. See the important notes above.
Shut off the power at the circuit breaker and completely remove the old
xturefromtheceiling,includingtheoldmountingstrap.
1.Takethemountingstrapassemblyfromthepartsbag.Oneendofnipple(F)
shouldbeattachedtomountingstrap(A)withwasherandhexnut(CandD)in
place.Canopyloop(H)isattachedtotheother.Securelyattachmountingstrap
(A)tothejunctionboxusingmountingscrews(B)andascrewdriver.
2. Unscrew canopy loop collar (I) from canopy loop (H). Pass canopy (G) over
themountedcanopylooptotesttheheight.Approximatelyhalfofthecanopy
loop’sexteriorthreadsshouldbeexposed,andthecanopyloopcollarshould
tsnuglyontothecanopyloop.Removecanopy(G)andadjusttheheightof
nipple(F)andcanopyloop(H)untilthedesiredheightisreached.
3.Oneofconnectorrods(N)hasthexture’swiresinside.Hookconnector
rods(N)totheframeatloops(Q)andthenpullthexturewiresuntiltaut.
Attach the top of connector rods (N) to canopy (S) at loops (R). Top loop (L)
isonthexturewires,butnotattachedtothebodyofthexture.Passthe
xturewiresthroughtoploop(L).Pullthewiresuntiltautandthreadtoploop
(L)ontothexturebodyatcanopy(S).
4.Bymeasuring,determinethecorrectnumberofchainlinksneededfor
properhangingheight.Ifnecessary,useapairofplierstoopenandremove
anyexcesschain.Attachonechainconnector(K)toeachendofchain(J).
Useoneofchainconnectors(K)toattachchain(J)totoploop(L)andclose
thechainconnector.Feedthexturewiresupthroughthechain(everythree
linksorso),pullingthewiresuntiltaut.Slidecanopyloopcollar(H)and
canopy (G) onto the chain/wire. Use the free chain connector (K) to attach
chain(J)tocanopyloop(H).
FINISHING THE INSTALLATION
6.Tightensmallroundhead(T)ontothetopofcanopy(S)usingascrewdriver.
7.Raisecanopy(G)uptotheceilingandslidecanopyloopcollar(I)upbeneaththecanopy.Tightlythreadcanopyloopcollar(I)onto
canopy loop (H) to secure canopy (G) in place.
7.Slideglassshades(P)oversockets(M)andsecureinplacewithsocketcovers(O).
8.
Installlightbulbs(notprovided)inaccordancewiththexture’sspecications.Donotexceedthemaximumrecommended
wattage.
Yourinstallationiscomplete.Turnonthepowerandtestthexture.
For Customer Service, please
contact the place of purchase.
Please note that the xture may be hung as a
pendant or a ushmount, please decide how
you would like the xture to be installed and
refer to the related instructions.
CLEANING TIPS
Treat the xture gently! Regular cleaning will reduce the need for deep cleaning. For regular cleaning, turn off the light and wipe down the
xture with a clean lint-free cotton or microber cloth. Never spray cleaner directly onto the xture.
CONNECTING THE WIRES
5.Haveanassistantsupportthextureweightwhilecompletingthewiring.Cutawayexcesswire.Attachthexture’swirestothe
powersupplywiresfromthejunctionbox.Connectblacktoblack(orsmooth);whitetowhite(orribbed);groundtoground(green
orcopper).Twisttheendsofthewirepairstogether,thentwistonawireconnector.Makesurealltwistsareinthesamedirection.If
thereisnogroundwire(greenorcopper)fromthejunctionbox,locategroundscrew(E)onmountingstrap(B)andwrapthexture’s
groundwirearoundthegreengroundscrew(E).Useascrewdrivertosecuregroundscrew(E)ontothemountingbracket.Tuckall
wiresneatlyintothejunctionbox.
Please note that
mounting strap
(A) is used in
this installation
option. In this
conguration,
canopy (S) will
need to be attached
to top loop (L).
S
R
Q
M
N
O
P
L
H
T
A
B
F
K
G
I
H
D
K
J
C
E
  • Page 1 1
  • Page 2 2

Golden Lighting 7041-3 BLK-CLR Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI