REMOVAL AND REPLACEMENT INSTRUCTIONS
FLOATS
1. Remove control panel, left and right side panels.
2. Disconnect wire leads of faulty float (or cut wires off).
3. Using 1/2" open end wrench, remove float from inside well. Wires or terminals will have to be cut off to remove.
Terminals will NOT fit through float mounting.
4. Install new float by feeding wires through mounting, pulling through from below. Tighten float with 1/2" open end
wrench.
5. Attach new terminals to wire ends. Plug into original locations.
SOLENOID VALVES/FLOW CONTROL
Positively identify and prove that a solenoid is defective before attempting replacement.
1. Remove control panel and left side panel.
2. Temporarily remove the limit thermostat and bracket from its location on the element retainer stops.
3. Disconnect the three (3) copper tubing connections from the solenoid assembly.
4. Remove the securing screw holding the solenoids in place (small bracket in front of solenoid assembly).
5. Solenoid assembly can be pushed back, turned and then pulled forward/sideways to remove.
6. Leads will need to be disconnected from origins, to remove assembly.
7. Remove and replace defective solenoid or flow control. Note arrangement, some care is required to re-assembly.
Note direction arrow on flow regulator (points towards rear of unit). TIGHTEN CONNECTIONS.
8. Re-install assembly into brackets.
9. Re-attach leads carefully. Refer to wiring diagram.
10. Re-attach copper tubing connections.
11. Install limit thermostat and bracket.
12. Install control panel and left side panel.
RELAYS
1. Remove control panel and right side panel.
2. Remove defective relay. Note wire/terminal locations.
3. Install new relay.
4. Replace control panel and right side panel.
CONTACTOR
1. Remove control panel and right side panel.
2. Disconnect wires and leads from contactor.
3. Remove contactor ((2) screws, diagonal).
4. Re-install control panel and right side panel.