2
SAFETY INSTRUCTIONS
This manual has safety information and instruc-
tions to help users eliminate or reduce the risk
of accidents and injuries.
RECOGNIZE SAFETY INFORMATION
This is the safety-alert symbol. When you see this
symbol in this manual, be alert to the potential
for personal injury.
Follow recommended precautions and safe op-
erating instructions.
UNDERSTAND SIGNAL WORDS
A signal word, WARNING OR CAUTION is used
with the safety-alert symbol. They give the level
of risk for potential injury.
Indicates a potentially hazard-
ous situation which, if not avoided, could result
in death or serious injury.
Indicates a potentially hazard-
ous situation which, if not avoided, may result in
minor or moderate injury.
When used without the safety
alert symbol indicates, a potentially hazardous
situation which, if not avoided, may result in
property damage.
Read and follow all safety information and in-
structions.
GENERAL INSTRUCTIONS
These instructions must be read and under-
stood before installation of this kit. This kit
must be installed by a Dometic Service Center
or a qualied service technician. Modication
of this product can be extremely hazardous
and could result in personal injury or property
damage.
A. This condensate pump is only functional with the models
listed on the front page. The condensate pump should
not be added to any air conditioner/heat pump/dehu-
midier (hereinafter referred to as the “unit”) not listed
in this manual. Product features or specications as
described or illustrated are subject to change without
notice.
B. Tools Required:
Cordless Drill W/Phillips Bit
Needle Nose Pliers
5/16" Nut Driver
Wire Cutter/Stripper
Electrical Tape
C. Contents of Kit:
1 each Condensate Pump Assembly
2 each Screws #10-18 x 0.5"
1 each Terminal Adapter (used on A/C models only)
2 each Strips Sealing Compound 3"
1 each Hose Clamp
1 each Instructions
INSTALLATION INSTRUCTIONS
A. Precautions
1. Read instructions carefully before attempting to
start installation.
2. Dometic, LLC will not be liable for any damages
or injury incurred due to failure in following these
instructions.
3. Installation must comply with the National Electrical
Code ANSA/NFPA-70 and CSA Standard C22.1
(latest edition) and any State or Local Codes or
regulations.
4. This equipment must be installed by qualied
personnel and some states require these people
to be licensed.
B. Requirements
1. The unit should be level within 1.5° side to side
and front to back. If the unit is not level within these
parameters, condensation will overow thru the
back up overow opening on the curb side of the
unit. See FIG. 2.
2. A 1/2" I.D. drain hose must be installed in the coach
and routed to the 14-1/4" x 14-1/4 (± 1/8") opening,
where the pump is to be installed.