Hoshizaki C-100BAF-DS User manual

Category
Ice cube makers
Type
User manual
Hoshizaki
“A Superior Degree
of Reliability”
www.hoshizaki.com
Models
C-100BAF
C-100BAF-DS
C-100BAF-AD
C-100BAF-ADDS
Self-Contained Cubelet
Hoshizaki America, Inc.
Number: 73180
Issued: 10-6-2010
Revised: 1-9-2012
SERVICE MANUAL
2
WARNING
Only qualied service technicians should install and service the icemaker. To
obtain the name and phone number of your local Hoshizaki Certied Service
Representative, visit www.hoshizaki.com. No service should be undertaken until
the technician has thoroughly read this Service Manual. Failure to service and
maintain the icemaker in accordance with this manual will adversely affect safety,
performance, component life, and warranty coverage and may result in costly water
damage. Proper installation is the responsibility of the installer. Product failure or
property damage due to improper installation is not covered under warranty.
Hoshizaki provides this manual primarily to assist qualied service technicians in the
service of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily
addressed, please call, send an e-mail message, or write to the Hoshizaki Technical
Support Department for assistance.
Phone: 1-800-233-1940; (770) 487-2331
Fax: 1-800-843-1056; (770) 487-3360
E-mail: techsuppor[email protected]
HOSHIZAKI AMERICA, INC.
618 Highway 74 South
Peachtree City, GA 30269
Attn: Hoshizaki Technical Support Department
Web Site: www.hoshizaki.com
NOTE: To expedite assistance, all correspondence/communication MUST include the
following information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem.
3
CONTENTS
Important Safety Information ................................................................................................. 5
I. Specications ...................................................................................................................... 7
A. C-100BAF ...................................................................................................................... 7
1. Auxiliary Codes A-1 and Earlier ................................................................................ 7
2. Auxiliary Codes A-2 and Later .................................................................................. 8
B. C-100BAF-DS ................................................................................................................ 9
1. Auxiliary Codes A-1 and Earlier ................................................................................ 9
2. Auxiliary Codes A-2 and Later ................................................................................ 10
C. C-100BAF-AD ..............................................................................................................11
1. Auxiliary Codes A-1 and Earlier ...............................................................................11
2. Auxiliary Codes A-2 and Later ................................................................................ 12
D. C-100BAF-ADDS ......................................................................................................... 13
1. Auxiliary Codes A-1 and Earlier .............................................................................. 13
2. Auxiliary Codes A-2 and Later ................................................................................ 14
II. General Information ......................................................................................................... 15
A. Construction ................................................................................................................ 15
1. Icemaker ................................................................................................................. 15
2. Icemaking Unit ........................................................................................................ 16
B. Sequence of Operation ............................................................................................... 17
1. Auxiliary Codes A-1 and Earlier .............................................................................. 17
2. Auxiliary Codes A-2 and Later ................................................................................ 18
III. Technical Information ...................................................................................................... 19
A. Water Circuit and Refrigeration Circuit ........................................................................ 19
1. Auxiliary Codes A-1 and Earlier .............................................................................. 19
2. Auxiliary Codes A-2 and Later ................................................................................ 20
B. Wiring Diagram ............................................................................................................ 21
1. Icemaker ................................................................................................................. 21
a) Auxiliary Codes A-1 and Earlier ......................................................................... 21
b) Auxiliary Codes A-2 and Later ............................................................................ 21
2. Icemaker with Optional Drain Pump HS-0248 ........................................................ 22
a) Auxiliary Codes A-1 and Earlier ......................................................................... 22
b) Auxiliary Codes A-2 and Later ............................................................................ 22
C. Performance Data ....................................................................................................... 23
IV. Service Diagnosis ........................................................................................................... 24
A. Ice Production Check .................................................................................................. 24
B. Diagnostic Procedure .................................................................................................. 24
1. Auxiliary Codes A-1 and Earlier .............................................................................. 24
2. Auxiliary Codes A-2 and Later ................................................................................ 26
C. Bin Control Check ....................................................................................................... 27
IMPORTANT
This manual should be read carefully before the icemaker is serviced. Read
the warnings and guidelines contained in this booklet carefully as they provide
essential information for the continued safe use, service, and maintenance of the
icemaker. Retain this booklet for any further reference that may be necessary.
4
D. Float Switch Check and Cleaning (auxiliary codes A-2 and later) ............................... 28
1. Float Switch Check ................................................................................................. 28
2. Float Switch Cleaning ............................................................................................. 29
E. Optional Drain Pump HS-0248 .................................................................................... 30
1. Overview ................................................................................................................. 30
2. Drain Pump Check ................................................................................................. 30
3. Float Switch Cleaning ............................................................................................. 32
F. Diagnostic Charts ........................................................................................................ 33
1. Auxiliary Codes A-1 and Earlier .............................................................................. 33
2. Auxiliary Codes A-2 and Later ................................................................................ 35
V. Removal and Replacement of Components .................................................................... 37
A. Service for Refrigerant Lines ....................................................................................... 37
1. Refrigerant Recovery .............................................................................................. 37
2. Brazing ................................................................................................................... 38
3. Evacuation and Recharge (R-134a) ....................................................................... 38
B. Important Notes for Component Replacement ............................................................ 39
C. Removal and Replacement of Evaporator Assembly Components ............................. 40
1. Upper Bearing Wear Check ................................................................................... 41
2. Removal and Replacement of Extruding Head ...................................................... 42
3. Removal and Replacement of Auger ...................................................................... 43
4. Removal and Replacement of Evaporator .............................................................. 44
5. Removal and Replacement of Mechanical Seal and Lower Housing .................... 45
6. Removal and Replacement of Gear Motor ............................................................. 47
VI. Maintenance ................................................................................................................... 48
A. Maintenance Schedule ................................................................................................ 49
B. Cleaning and Sanitizing Instructions ........................................................................... 50
1. Auxiliary Codes A-1 and Earlier .............................................................................. 50
2. Auxiliary Codes A-2 and Later ................................................................................ 54
C. Storage Bin Drain ........................................................................................................ 57
D. Condenser ................................................................................................................... 58
VII. Preparing the Icemaker for Periods of Non-Use ............................................................ 59
VIII. Disposal ........................................................................................................................ 60
5
Important Safety Information
Throughout this manual, notices appear to bring your attention to situations which could
result in death, serious injury, damage to the appliance, or damage to property.
WARNING Indicates a hazardous situation which could result in death or
serious injury.
NOTICE Indicates a situation which could result in damage to the
appliance or property.
IMPORTANT Indicates important information about the use and care of the
appliance.
WARNING
This icemaker should be destined only to the use for which it has been expressly
conceived. Any other use should be considered improper and therefore dangerous. The
manufacturer cannot be held responsible for injury or damage resulting from improper,
incorrect, and unreasonable use. Failure to service and maintain the icemaker in
accordance with this manual will adversely affect safety, performance, component life,
and warranty coverage and may result in costly water damage.
To reduce the risk of death, electric shock, serious injury, or re, follow basic
precautions including the following:
• Only qualied service technicians should install and service this icemaker.
This icemaker must be installed in accordance with applicable national, state, and local
codes and regulations.
This icemaker requires an independent power supply of proper capacity. See the
nameplate for electrical specications. Failure to use an independent power supply of
proper capacity can result in a tripped breaker, blown fuse, damage to existing wiring,
or component failure. This could lead to heat generation or re.
THIS ICEMAKER MUST BE GROUNDED: This icemaker is equipped with a
NEMA5-15 three-prong grounding plug to reduce the risk of potential shock
hazards. It must be plugged into a properly grounded, independent 3-prong wall outlet.
If the outlet is a 2-prong outlet, it is your personal responsibility to have a qualied
electrician replace it with a properly grounded, independent 3-prong wall outlet. Do not
remove the ground prong from the power cord and do not use an adapter plug.
• Do not use an extension cord.
To reduce the risk of electric shock, make sure the power switch is in the "OFF" position
before plugging in or unplugging the icemaker.
To reduce the risk of electric shock, do not touch the power switch or plug with damp
hands.
• Do not use an icemaker with a damaged power cord. The power cord should not be
altered, jerked, bundled, weighed down, pinched, or tangled. Such actions could result
in electric shock or re. To unplug the icemaker, be sure to pull the plug, not the cord,
and do not jerk the cord.
• Do not make any alterations to the icemaker. Alterations could result in electric shock,
injury, re, or damage to the icemaker.
• Do not place ngers or any other objects into the ice discharge opening.
6
WARNING, continued
This appliance is not intended for use by persons (including children) with reduced
physical, sensory, or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Young children should be properly supervised around this appliance.
• Do not climb, stand, or hang on the icemaker or icemaker door or allow children or
animals to do so. Serious injury could occur or the icemaker could be damaged.
• Be careful not to pinch ngers when opening and closing the door. Be careful when
opening and closing the door when children are in the area.
• Do not use combustible spray or place volatile or ammable substances near the
icemaker. They might catch re.
• Keep the area around the icemaker clean. Dirt, dust, or insects in the icemaker could
cause harm to individuals or damage to the icemaker.
NOTICE
• Protect the oor when moving the icemaker to prevent damage to the oor.
• Follow the instructions in this manual carefully to reduce the risk of costly water
damage.
• In areas where water damage is a concern, install in a contained area with a oor drain.
• Install the icemaker in a location that stays above freezing. Normal operating ambient
temperature must be within 45°F to 100°F (7°C to 38°C).
• If using the optional drain pump (HS-0248), test its operation every time the icemaker is
cleaned and sanitized. See "IV.E.2. Drain Pump Check" for details. If the optional drain
pump is not operating properly, water could back up and overow, leading to costly
water damage.
To help ensure that the storage bin drain remains clear, follow the instructions in "VI.C.
Storage Bin Drain" once every 3 months or as often as necessary for conditions. If
the storage bin drain becomes clogged, water could build up in the bin and overow,
leading to costly water damage.
• If water collects in the bin and will not drain, turn off the icemaker and close the water
supply line shut-off valve. Locate and resolve the issue.
To help protect against unseen water issues, this icemaker features a drip tray and
emergency overow hose. See Fig. 1. If there is water in the drip tray, coming out of
the reservoir emergency overow hose, or seeping from the base of the icemaker, turn
off the icemaker and close the water supply line shut-off valve. Locate and resolve the
issue. Failure to do so could lead to costly water damage.
• Do not leave the icemaker on during extended periods of non-use, extended absences,
or in sub-freezing temperatures. To properly prepare the icemaker for these occasions,
follow the instructions in "VII. Preparing the Icemaker for Periods of Non-Use."
• Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear
of obstruction.
• Do not place objects on top of the icemaker.
The storage bin is for ice use only. Do not store anything else in the storage bin.
7
I. Specications
A. C-100BAF
1. Auxiliary Codes A-1 and Earlier
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 115/60/1
AMPERAGE 4.0 A
MINIMUM CIRCUIT AMPACITY 15 A
MAXIMUM FUSE SIZE 15 A
A
PPROXIMATE ICE PRODUCTION
A
mbient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day
)
70 *92 (42) 89 (40) 84 (38)
Reference without *marks 80 81 (37) 71 (32) 66 (30)
90 66 (30) *62 (28) 57 (26)
100 55 (25) 54 (24) *49 (22)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 90%
A
PPROXIMATE STORAGE CAPACITY 29 lbs. (13 kg) [Bin Control Setting 22 lbs. (10.0 kg)]
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 310 (12.1) 297 (7.7)
WATER gal./24HR (gal./100 lbs.) 7.7 (12) 11.1 (12)
EXTERIOR DIMENSIONS (WxDxH) 14.9" x 22.6" x 33.5" (378 x 575 x 850mm)
EXTERIOR FINISH Stainless steel, Galvanized Steel (Rear)
WEIGHT Net 108 lbs. ( 49 kg ), Shipping 120 lbs. (54 kg)
CONNECTIONS - ELECTRIC Cord Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 1/2" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Drive Auger (80W Gear Motor)
ICE MAKING WATER CONTROL Mechanical float valve
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Thermostat
COMPRESSOR Hermetic, Model QA51K13GAU6
CONDENSER
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Capillary Tube
REFRIGERANT CHARGE R134a 3.17 oz. (90 g)
DESIGN PRESSURE High 240 PSIG, Low 120 PSIG
P.C. BOARD CIRCUIT PROTECTION N/A
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker
LOW WATER PROTECTION Suction Temperature Safety
ACCESSORIES - SUPPLIED Ice Scoop; Drain Pump Adapter Hose
- REQUIRED N/A
- OPTION Drain Pump
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 7 - 113 PSIG
AGENCY UL OUTDOOR APPROVED, cUL
ETL
Air-cooled, Fin and tube type
8
A. C-100BAF, continued
2. Auxiliary Codes A-2 and Later
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 115/60/1
AMPERAGE 4.0 A
MINIMUM CIRCUIT AMPACITY 15 A
MAXIMUM FUSE SIZE 15 A
A
PPROXIMATE ICE PRODUCTION
A
mbient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day ) 70 *92 (42) 89 (40) 84 (38)
Reference without *marks 80 81 (37) 71 (32) 66 (30)
90 66 (30) *62 (28) 57 (26)
100 55 (25) 54 (24) *49 (22)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 90%
A
PPROXIMATE STORAGE CAPACIT
Y
29 lbs. (13 kg) [Bin Control Setting 22 lbs. (10.0 kg)]
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 310 (12.1) 297 (7.7)
WATER gal./24HR (gal./100 lbs.) 7.7 (12) 11.1 (12)
EXTERIOR DIMENSIONS (WxDxH) 14.9" x 22.6" x 33.5" (378 x 575 x 850mm)
EXTERIOR FINISH Stainless steel, Galvanized Steel (Rear)
WEIGHT Net 108 lbs. ( 49 kg ), Shipping 120 lbs. (54 kg)
CONNECTIONS - ELECTRIC Cord Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 1/2" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Drive Auger (80W Gear Motor)
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Thermostat
COMPRESSOR Hermetic, Model QA51K13GAU6
CONDENSER
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Capillary Tube
REFRIGERANT CHARGE R134a 3.17 oz. (90 g)
DESIGN PRESSURE High 240 PSIG, Low 120 PSIG
P.C. BOARD CIRCUIT PROTECTION N/A
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker
LOW WATER PROTECTION Float Switch and Timer
ACCESSORIES - SUPPLIED Ice Scoop; Drain Pump Adapter Hose
- REQUIRED N/A
- OPTION Drain Pump
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 7 - 113 PSIG
AGENCY UL OUTDOOR APPROVED, cUL
ETL
Air-cooled, Fin and tube type
9
B. C-100BAF-DS
1. Auxiliary Codes A-1 and Earlier
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 115/60/1
AMPERAGE 4.0 A
MINIMUM CIRCUIT AMPACITY 15 A
MAXIMUM FUSE SIZE 15 A
A
PPROXIMATE ICE PRODUCTION
A
mbient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day
)
70 *92 (42) 89 (40) 84 (38)
Reference without *marks 80 81 (37) 71 (32) 66 (30)
90 66 (30) *62 (28) 57 (26)
100 55 (25) 54 (24) *49 (22)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 90%
A
PPROXIMATE STORAGE CAPACITY 29 lbs. (13 kg) [Bin Control Setting 22 lbs. (10.0 kg)]
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 310 (12.1) 297 (7.7)
WATER gal./24HR (gal./100 lbs.) 7.7 (12) 11.1 (12)
EXTERIOR DIMENSIONS (WxDxH) 14.9" x 22.6" x 33.5" (378 x 575 x 850mm)
EXTERIOR FINISH Stainless steel, Galvanized Steel (Rear)
WEIGHT Net 108 lbs. ( 49 kg ), Shipping 120 lbs. (54 kg)
CONNECTIONS - ELECTRIC Cord Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 1/2" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Drive Auger (80W Gear Motor)
ICE MAKING WATER CONTROL Mechanical float valve
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Thermostat
COMPRESSOR Hermetic, Model QA51K13GAU6
CONDENSER
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Capillary Tube
REFRIGERANT CHARGE R134a 3.17 oz. (90 g)
DESIGN PRESSURE High 240 PSIG, Low 120 PSIG
P.C. BOARD CIRCUIT PROTECTION N/A
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker
LOW WATER PROTECTION Suction Temperature Safety
ACCESSORIES - SUPPLIED Ice Scoop; Drain Pump Adapter Hose
- REQUIRED Wood Overlay and Handle (Not Included)
- OPTION Drain Pump
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 7 - 113 PSIG
AGENCY UL OUTDOOR APPROVED, cUL
ETL
Air-cooled, Fin and tube type
10
B. C-100BAF-DS, continued
2. Auxiliary Codes A-2 and Later
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 115/60/1
AMPERAGE 4.0 A
MINIMUM CIRCUIT AMPACITY 15 A
MAXIMUM FUSE SIZE 15 A
A
PPROXIMATE ICE PRODUCTION
A
mbient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day ) 70 *92 (42) 89 (40) 84 (38)
Reference without *marks 80 81 (37) 71 (32) 66 (30)
90 66 (30) *62 (28) 57 (26)
100 55 (25) 54 (24) *49 (22)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 90%
A
PPROXIMATE STORAGE CAPACIT
Y
29 lbs. (13 kg) [Bin Control Setting 22 lbs. (10.0 kg)]
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 310 (12.1) 297 (7.7)
WATER gal./24HR (gal./100 lbs.) 7.7 (12) 11.1 (12)
EXTERIOR DIMENSIONS (WxDxH) 14.9" x 22.6" x 33.5" (378 x 575 x 850mm)
EXTERIOR FINISH Stainless steel, Galvanized Steel (Rear)
WEIGHT Net 108 lbs. ( 49 kg ), Shipping 120 lbs. (54 kg)
CONNECTIONS - ELECTRIC Cord Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 1/2" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Drive Auger (80W Gear Motor)
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Thermostat
COMPRESSOR Hermetic, Model QA51K13GAU6
CONDENSER
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Capillary Tube
REFRIGERANT CHARGE R134a 3.17 oz. (90 g)
DESIGN PRESSURE High 240 PSIG, Low 120 PSIG
P.C. BOARD CIRCUIT PROTECTION N/A
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker
LOW WATER PROTECTION Float Switch and Timer
ACCESSORIES - SUPPLIED Ice Scoop; Drain Pump Adapter Hose
- REQUIRED Wood Overlay and Handle (Not Included)
- OPTION Drain Pump
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 7 - 113 PSIG
AGENCY UL OUTDOOR APPROVED, cUL
ETL
Air-cooled, Fin and tube type
11
C. C-100BAF-AD
1. Auxiliary Codes A-1 and Earlier
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 115/60/1
AMPERAGE 4.0 A
MINIMUM CIRCUIT AMPACITY 15 A
MAXIMUM FUSE SIZE 15 A
A
PPROXIMATE ICE PRODUCTION
A
mbient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day
)
70 *92 (42) 89 (40) 84 (38)
Reference without *marks 80 81 (37) 71 (32) 66 (30)
90 66 (30) *62 (28) 57 (26)
100 55 (25) 54 (24) *49 (22)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 90%
A
PPROXIMATE STORAGE CAPACITY 29 lbs. (13 kg) [Bin Control Setting 22 lbs. (10.0 kg)]
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 310 (12.1) 297 (7.7)
WATER gal./24HR (gal./100 lbs.) 7.7 (12) 11.1 (12)
EXTERIOR DIMENSIONS (WxDxH) 14.9" x 22.6" x 31.5" (378 x 575 x 800mm)
EXTERIOR FINISH Stainless steel, Galvanized Steel (Rear)
WEIGHT Net 104 lbs. ( 47 kg ), Shipping 115 lbs. (52 kg) without pallet
CONNECTIONS - ELECTRIC Cord Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 1/2" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Drive Auger (80W Gear Motor)
ICE MAKING WATER CONTROL Mechanical float valve
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Thermostat
COMPRESSOR Hermetic, Model QA51K13GAU6
CONDENSER
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Capillary Tube
REFRIGERANT CHARGE R134a 3.17 oz. (90 g)
DESIGN PRESSURE High 240 PSIG, Low 120 PSIG
P.C. BOARD CIRCUIT PROTECTION N/A
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker
LOW WATER PROTECTION Suction Temperature Safety
ACCESSORIES - SUPPLIED Ice Scoop; pump adapter hose
- REQUIRED N/A
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 7 - 113 PSIG
AGENCY UL OUTDOOR APPROVED, cUL
ETL
Air-cooled, Fin and tube type
12
C. C-100BAF-AD, continued
2. Auxiliary Codes A-2 and Later
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 115/60/1
AMPERAGE 4.0 A
MINIMUM CIRCUIT AMPACITY 15 A
MAXIMUM FUSE SIZE 15 A
A
PPROXIMATE ICE PRODUCTION
A
mbient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day ) 70 *92 (42) 89 (40) 84 (38)
Reference without *marks 80 81 (37) 71 (32) 66 (30)
90 66 (30) *62 (28) 57 (26)
100 55 (25) 54 (24) *49 (22)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 90%
A
PPROXIMATE STORAGE CAPACIT
Y
29 lbs. (13 kg) [Bin Control Setting 22 lbs. (10.0 kg)]
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 310 (12.1) 297 (7.7)
WATER gal./24HR (gal./100 lbs.) 7.7 (12) 11.1 (12)
EXTERIOR DIMENSIONS (WxDxH) 14.9" x 22.6" x 31.5" (378 x 575 x 800mm)
EXTERIOR FINISH Stainless steel, Galvanized Steel (Rear)
WEIGHT Net 104 lbs. ( 47 kg ), Shipping 115 lbs. (52 kg) without pallet
CONNECTIONS - ELECTRIC Cord Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 1/2" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Drive Auger (80W Gear Motor)
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Thermostat
COMPRESSOR Hermetic, Model QA51K13GAU6
CONDENSER
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Capillary Tube
REFRIGERANT CHARGE R134a 3.17 oz. (90 g)
DESIGN PRESSURE High 240 PSIG, Low 120 PSIG
P.C. BOARD CIRCUIT PROTECTION N/A
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker
LOW WATER PROTECTION Float Switch and Timer
ACCESSORIES - SUPPLIED Ice Scoop; pump adapter hose
- REQUIRED N/A
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 7 - 113 PSIG
AGENCY UL OUTDOOR APPROVED, cUL
ETL
Air-cooled, Fin and tube type
13
D. C-100BAF-ADDS
1. Auxiliary Codes A-1 and Earlier
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 115/60/1
AMPERAGE 4.0 A
MINIMUM CIRCUIT AMPACITY 15 A
MAXIMUM FUSE SIZE 15 A
A
PPROXIMATE ICE PRODUCTION
A
mbient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day
)
70 *92 (42) 89 (40) 84 (38)
Reference without *marks 80 81 (37) 71 (32) 66 (30)
90 66 (30) *62 (28) 57 (26)
100 55 (25) 54 (24) *49 (22)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 90%
A
PPROXIMATE STORAGE CAPACITY 29 lbs. (13 kg) [Bin Control Setting 22 lbs. (10.0 kg)]
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 310 (12.1) 297 (7.7)
WATER gal./24HR (gal./100 lbs.) 7.7 (12) 11.1 (12)
EXTERIOR DIMENSIONS (WxDxH) 14.9" x 22.6" x 31.5" (378 x 575 x 800mm)
EXTERIOR FINISH Stainless steel, Galvanized Steel (Rear)
WEIGHT Net 104 lbs. ( 47 kg ), Shipping 115 lbs. (52 kg) without pallet
CONNECTIONS - ELECTRIC Cord Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 1/2" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Drive Auger (80W Gear Motor)
ICE MAKING WATER CONTROL Mechanical float valve
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Thermostat
COMPRESSOR Hermetic, Model QA51K13GAU6
CONDENSER
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Capillary Tube
REFRIGERANT CHARGE R134a 3.17 oz. (90 g)
DESIGN PRESSURE High 240 PSIG, Low 120 PSIG
P.C. BOARD CIRCUIT PROTECTION N/A
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker
LOW WATER PROTECTION Suction Temperature Safety
ACCESSORIES - SUPPLIED Ice Scoop; Drain Pump Adapter Hose
- REQUIRED Wood Overlay and Handle (Not Included)
- OPTION Drain Pump
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 7 - 113 PSIG
AGENCY UL OUTDOOR APPROVED, cUL
ETL
Air-cooled, Fin and tube type
14
D. C-100BAF-ADDS, continued
2. Auxiliary Codes A-2 and Later
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 115/60/1
AMPERAGE 4.0 A
MINIMUM CIRCUIT AMPACITY 15 A
MAXIMUM FUSE SIZE 15 A
A
PPROXIMATE ICE PRODUCTION
A
mbient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day ) 70 *92 (42) 89 (40) 84 (38)
Reference without *marks 80 81 (37) 71 (32) 66 (30)
90 66 (30) *62 (28) 57 (26)
100 55 (25) 54 (24) *49 (22)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 90%
A
PPROXIMATE STORAGE CAPACIT
Y
29 lbs. (13 kg) [Bin Control Setting 22 lbs. (10.0 kg)]
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 310 (12.1) 297 (7.7)
WATER gal./24HR (gal./100 lbs.) 7.7 (12) 11.1 (12)
EXTERIOR DIMENSIONS (WxDxH) 14.9" x 22.6" x 31.5" (378 x 575 x 800mm)
EXTERIOR FINISH Stainless steel, Galvanized Steel (Rear)
WEIGHT Net 104 lbs. ( 47 kg ), Shipping 115 lbs. (52 kg) without pallet
CONNECTIONS - ELECTRIC Cord Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Outlet 1/2" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Drive Auger (80W Gear Motor)
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Thermostat
COMPRESSOR Hermetic, Model QA51K13GAU6
CONDENSER
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Capillary Tube
REFRIGERANT CHARGE R134a 3.17 oz. (90 g)
DESIGN PRESSURE High 240 PSIG, Low 120 PSIG
P.C. BOARD CIRCUIT PROTECTION N/A
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker
LOW WATER PROTECTION Float Switch and Timer
ACCESSORIES - SUPPLIED Ice Scoop; Drain Pump Adapter Hose
- REQUIRED Wood Overlay and Handle (Not Included)
- OPTION Drain Pump
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 7 - 113 PSIG
AGENCY UL OUTDOOR APPROVED, cUL
ETL
Air-cooled, Fin and tube type
15
II. General Information
A. Construction
1. Icemaker
Rear
Float-Operated
Water Valve
Air-Cooled Condenser and
Condenser Fan Motor
Front
Control Box
Water
Reservoir
Evaporator
Assembly
Upper
Rear
Panel
Suction
Temperature
Safety
Bin Control
Thermostat
Fig. 1
Front Panel
Louver
Top Panel
Power Switch
Gear Motor Protector
(External Overload)
Reset Switch
Ice Discharge Opening
Bin Control
Thermostat Bulb
Slope
C-100BAF-AD Shown
C-100BAF-AD Shown
Bin Control
Thermostat
Inlet Water Valve
Water
Reservoir
Float Switch
Compressor
Evaporator
Assembly
Gear Motor
Drier
Auxiliary Codes
A-1 and Earlier
Auxiliary Codes
A-2 and Later
Drip
Tray
Reservoir Emergency Overow Hose
Auxiliary Codes A-2 and Later
Compressor
Gear Motor
Drier
Top Panel
Lower
Rear
Panel
Upper
Rear
Panel
Gear Motor
Drain Pan
Evaporator
Condensate
Drain Pan
Gear Motor
Drain Pan
Evaporator
Condensate
Drain Pan
Power
Cord
Lower
Rear
Panel
Power
Cord
16
2. Icemaking Unit
Socket Head Cap Screw
Gear Motor
Spline Coupling
Housing and
Lower Bearing
O-Ring
Mechanical Seal
Cylinder
Auger
Extruding Head
and Upper
Bearing
Cutter (motionless)
Insulation
Socket Head
Cap Screw
with Washer
Hex Head
Bolt with
Washer
Fig. 2
Evaporator Flange
17
B. Sequence of Operation
1. Auxiliary Codes A-1 and Earlier
After the power switch is placed in the "ON" position, the steps in the sequence are as
outlined below.
a) Freeze Cycle
BCH, GM, FM, CR, and Comp energize. NOTICE! Some units contain a sticker that
states: "The bin control heater has been disconnected. DO NOT reconnect the
bin control heater." In this case, leave BCH disconnected or replace BC assembly
with 3A2561A03. Ice production starts 4 to 6minutes after Comp energizes depending
on ambient and water conditions. The freeze cycle continues until BC shuts down the
icemaker or power is turned off to the icemaker. Rell: The oat-operated WV allows
water into the reservoir as needed to continue the icemaking process. If the water supply
is cut off or GM stops during the freeze cycle, the cold evaporator temperature causes
STS to open and de-energize all components except BCH and optional drain pump
HS-0248.
b) Bin Control Thermostat Shutdown
Ice lls storage bin to level of BC. BC opens within 10 seconds after ice contact. When
BC opens, BCH remains energized. GM, FM, CR, and Comp de-energize. When ice level
lowers and BC closes, the icemaker starts operating again.
C-100BAF Series Sequence Flow Chart and Component Operation
(auxiliary codes A-1 and earlier)
Legend: BC–bin control thermostat; BCH–bin control heater; Comp–compressor;
CR–compressor relay; FM–fan motor; GM–gear motor; STS–suction temperature
safety (low water/freeze-up safety); WV–inlet water valve
2. Shutdown
1. Freeze Cycle
Bin Full
BC closed
Low Water/
Freeze-Up Safety
BC closed
STS open
BCH continues
Comp de-energized
FM de-energized
GM de-energized
When STS closes,
icemaker restarts at
1. Freeze Cycle.
STS
open
BC
open
Float-operated WV allows
water into reservoir as needed.
BC closed
STS closed
BCH energized
Comp energized
FM energized
GM energized
Power Switch
"ON"
BC closed
STS closed
BCH continues
Comp continues
FM continues
GM continues
BC open
STS closed
BCH continues
Comp de-energized
FM de-energized
GM de-energized
Rell
18
3. Shutdown
2. Freeze Cycle
Bin Full
Power Switch
"ON"
BC open
BCH continues
Comp de-energized
FM de-energized
GM de-energized
WV de-energized
BC closed
BC closed
LF/S closed
UF/S closed
BCH continues
Comp energized
FM energized
GM energized
WV de-energized
BC closed
UF/S open
LF/S open
FT starts (90 sec.)
BCH continues
Comp continues
FM continues
GM continues
WV energized
BC closed
UF/S open
LF/S open
BCH energized
WV energized
1. Fill Cycle
BC closed
LF/S closed
UF/S closed
FT terminated
BCH continues
Comp continues
FM continues
GM continues
WV de-energized
Low Water Safety
BC closed
UF/S open
FT exceeded
BCH continues
WV continues
Comp de-energized
FM de-energized
GM de-energized
Rell
FT (in TDR)
Maximum 90 seconds
When UF/S closes,
icemaker restarts at
2. Freeze Cycle.
90 seconds
FT
exceeded
BC
open
2. Auxiliary Codes A-2 and Later
After the power switch is placed in the "ON" position, the steps in the sequence are as
outlined below.
a) Fill Cycle
LF/S and UF/S open, BCH and WV energize. LF/S closes. Nothing happens at this time.
Reservoir continues to ll until UF/S closes.
b) Freeze Cycle
UF/S closes. BCH remains energized. WCR, TDR, GM, FM, CR, and Comp energize. WV
de-energizes. Ice production starts 4 to 6minutes after Comp energizes depending on
ambient and water conditions. F/S controls WV to rell as needed during the freeze cycle.
The freeze cycle continues until BC shuts down the icemaker or power is turned off to
the icemaker. Rell: As ice is produced, the water level in the reservoir drops and UF/S
opens. When UF/S opens, a latching circuit through LF/S and WCR keeps WCR, TDR,
GM, FM, CR, and Comp energized. When LF/S opens, WCR de-energizes, cutting power
to TDR terminal #5 (O wire) and starting FT. WV energizes. Water lls the reservoir, UF/S
closes. WCR energizes, restoring power to TDR terminal #5 (O wire) and resetting FT.
WV de-energizes. If UF/S remains open longer than 90 seconds, FT terminates, cutting
power to TDR terminal#9 (R wire). GM, FM, CR, and Comp de-energize. WV remains
energized until UF/S closes.
c) Bin Control Thermostat Shutdown
Ice lls storage bin to level of BC. BC opens within 10 seconds after ice contact. When
BC opens, BCH remains energized. WCR, TDR, GM, FM, CR, and Comp de-energize.
When ice level lowers and BC closes, the icemaker starts operating again.
C-100BAF Series Sequence Flow Chart and Component Operation
(auxiliary codes A-2 and later)
Legend: BC–bin control thermostat; BCH–bin control heater; Comp–compressor;
CR–compressor relay; FM–fan motor; FT–90-second ll timer (low water safety;
internal to TDR); GM–gear motor; LF/S–lower oat switch; TDR–time delay relay;
UF/S–upper oat switch; WCR–water control relay; WV–inlet water valve
19
III. Technical Information
A. Water Circuit and Refrigeration Circuit
1. Auxiliary Codes A-1 and Earlier
Drier
Condenser
Fan Motor
Condenser
Compressor
Float-Operated
Inlet Water Valve
Water
Reservoir
Water Level
Suction
Temperature
Safety
Gear
Motor
Evaporator
Assembly
Water Inlet
Water Supply
Fig. 3a
Capillary Tube
Overow Hose
Suction
Discharge
20
Drier
Condenser
Fan Motor
Condenser
Compressor
Float Switch
Water Reservoir
Water Level
Gear
Motor
Evaporator
Assembly
Water Inlet
Water Supply
Capillary Tube
Overow Hoses
Suction
Discharge
Inlet Water Valve
2. Auxiliary Codes A-2 and Later
Fig. 3b
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60