Control4® Essential Lighting Wiring Guide
SCREW TERMINALS ON ESSENTIAL LIGHTING PRODUCTS
Control4 Essential Lighting products feature convenient dual quick-connect
holes and screw terminals with the ability to daisy-chain devices for convenient
installation.
Important wiring information
Essential Lighting products are only rated for use with copper wire.
Use 14 AWG or larger wires suitable for at least 80 °C
To use the quick-connect holes, strip 5/8" (16 mm) of insulation from the
wires.
To use the screw terminals, strip 1" (25 mm) of insulation from the wires.
Wiring examples
SWITCH-LEG CONFIGURATION
This diagrams shows a sample wiring configuration using an Essential Forward Phase Dimmer (C4-V-FPD120) in a switch-leg (no neutral
in the wallbox) situation.
Switch-leg (no neutral)
Note: The Essential Forward Phase Dimmer does not support an Auxiliary Keypad when installed in a switch-leg configuration.
Note: The Essential Switch does not support switch-leg configuration.
Switch-leg dimmer
(Forward Phase Dimmer)
Load
Line
Ground
Neutral
Light (load)
From breaker box
WIRING LEGEND
Black
Red
Gray
Green
Blue
Red/
White
Important! Wiring colors in these diagrams
are representative and will vary depending
on your installation.
Line voltage
Load (to light)
Neutral
Earth ground
Traveler
Load/neutral
(switch-leg)
ESSENTIAL FORWARD PHASE DIMMER ESSENTIAL SWITCH ESSENTIAL AUXILIARY KEYPAD
https://manual-hub.com/
2
3-WAY CONFIGURATIONS WITH AN ESSENTIAL AUXILIARY KEYPAD
These diagrams show sample 3-way wiring configurations using an Essential Forward Phase Dimmer (C4-V-FPD120) or Switch (C4-V-
SW120-277) with one Essential Auxiliary Keypad (C4-V-AUX).
3-way Line - Load - Light (Dimmer at line switch location)
3-way Line - Load - Light (Dimmer at load switch location)
Out to load switch
From breaker box
Line Switch
(Forward Phase Dimmer or Switch)
Load Switch
(Auxiliary Keypad)
Load
Line
Ground
Traveler
Neutral
Ground
Traveler
Neutral
Out to light (load)
Out to line switch
From breaker box
Load Switch
(Forward Phase Dimmer or Switch)
Line Switch
(Auxiliary Keypad)
Load
Line
Ground
Traveler
Neutral
Ground
Traveler
Neutral
Out to light (load)
https://manual-hub.com/
3
3-way Load - Light - Line (Light between Line and Load switch locations)
4-WAY CONFIGURATION WITH ESSENTIAL AUXILIARY KEYPADS
This diagram shows a sample 4-way wiring configuration using an Essential Forward Phase Dimmer (C4-V-FPD120) or Switch (C4-V-
SW120-277) with two Essential Auxiliary Keypads (C4-V-AUX). Daisy-chain each additional Auxiliary Keypad by extending the Ground,
Traveler, and Neutral to each keypad.
4-way configuration
Note: The Essential Forward Phase Dimmer and Switch support up to five Auxiliary Keypads, daisy-chained as shown above in
3-, 4-, 5-, or 6-way wiring configurations.
Note: Each Essential Auxiliary Keypad can be up to 100 m (300 ft) from the dimmer, switch, or another keypad. Total distance
from the dimmer or switch to all the connected keypads can be up to 300 m (1000 ft).
From breaker box
Load Switch
(Forward Phase Dimmer or Switch)
Line Switch
(Auxiliary Keypad)
Load
Line
Ground
Traveler
Neutral
Ground
Traveler
Neutral
Out to light (load)
Light (load)
Out to line switch
From breaker box
Load Switch
(Forward Phase Dimmer or Switch)
Line Switch
(Auxiliary Keypad)
Load
Line
Ground
Traveler
Neutral
Ground
Traveler
Neutral
Out to light (load) Out to line switch
Line Switch
(Auxiliary Keypad)
Ground
Traveler
Neutral
https://manual-hub.com/
4
MULTI-GANG BOX WIRING EXAMPLE
This diagram shows a sample multi-gang box configuration with an additional 3-way location using mutliple Essential Forward Phase
Dimmers (C4-V-FPD120) or Switches (C4-V-SW120-277) and an Essential Auxiliary Keypad (C4-V-AUX).
Tip: Use the two quick-connect terminals to daisy-chain your wiring to save clutter in a multi-gang box installation. For
example, take ground into each dimmer and then out to each light.
Three-gang box with one 3-way
Regulatory/Safety information
To review regulatory information for your particular Control4 products, see the information located on the Control4 website at
ctrl4.co/reg.
Warranty
Visit ctrl4.co/warranty for details.
More information
More information on Essential Lighting products can be found on our website or in the Dealer Portal. Open the URL below or scan the
QR code.
From breaker box
Forward Phase Dimmer or Switch
Load
Ground
Neutral
Out to light (load)
Out to line switch
Auxiliary Keypad
Ground
Traveler
Neutral
Load
Ground
Neutral
Line
Line
Load
Ground
Neutral
Traveler
Line
Forward Phase Dimmer or Switch
Forward Phase Dimmer or Switch
ESSENTIAL LIGHTING HELP
ctrl4.co/essential-wiring
ESSENTIAL LIGHTING PRODUCTS
ctrl4.co/essential-lighting
Copyright ©2020, Wirepath Home Systems, LLC. All rights reserved.Control4 and Snap AV and their respective
logos are registered trademarks or trademarks of Wirepath Home Systems, LLC, dba “Control4” and/or dba
“SnapAV” in the United States and/or other countries. 4Store, 4Sight, Control4 My Home, Snap AV, and Wirepath
are also registered trademarks or trademarks ofWirepath Home Systems, LLC. Other names and brands may be
claimed as the property of their respective owners. All specifications subject to change without notice.
DOC-00501-A
03-03-2020 DH
https://manual-hub.com/
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Control4 CA-V-FPD120-WH In Wall Wireless Dimmer User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI