Acuity Brands SLOT 4 User manual

Category
Floodlights
Type
User manual

Acuity Brands SLOT 4 is a versatile and energy-efficient LED lighting solution designed for commercial and industrial applications. With its sleek design and powerful illumination, SLOT 4 offers a range of features to meet your specific lighting needs.

Acuity Brands SLOT 4 is a versatile and energy-efficient LED lighting solution designed for commercial and industrial applications. With its sleek design and powerful illumination, SLOT 4 offers a range of features to meet your specific lighting needs.

1
SLOT 2/4
Important Safety Instructions
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit.
Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection
with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered
sufficiently for the purchaser's or owner's purposes, this matter should be referred to Acuity Brands Lighting, Inc.
It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum
light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household
detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above
manner, replacing damaged gaskets as necessary.
Maintenance of the luminaires should be performed by person(s) familiar with the luminaires' construction and operation and any hazards
involved. Regular fixture maintenance programs are recommended.
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please
read all warnings and instructions included with and on the fixture box and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Installation and service of luminaires should be performed by a qualified licensed electrician.
Installation Instructions - Direct Wall S2WD/S4WD
Allow lamp/fixture to cool before handling.
enclosure or light source.
Do not exceed maximum wattage marked on luminaire label.
Follow all manufacturer’s warnings,
and restrictions for: driver type, burning position, mounting
locations/methods, replacement and recycling.
WARNING
RISK OF BURN
Do not touch
recommendations
WARNING
RISK OF ELECTRIC SHOCK
Disconnect or turn off power before installation or servicing.
Verify that supply voltage is correct by comparing it with the
luminaire label information.
Make all electrical and grounded connections in accordance
National Electrical Code (NEC) and any applicable
All wiring connections should be capped with UL approved
connectors.
with the
local code requirements.
recognized wire
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
Pre-Launch
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
2
Important Safety Instructions
Wear gloves and safety glasses at all
luminaire from carton, installing, servicing or performing
maintenance.
Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF INJURY
times when removing Keep combustible and other materials
lamp/lens.
Do not operate in close proximity to
materials or substances affected by heat or drying.
CAUTION
RISK OF FIRE
that can burn, away from
persons, combustible
Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
Only use fixture in its intended location.
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility
with the luminaire prior to installation. LED fixtures must be powered directly o ffa switched circuit.
Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture.
Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
LED products are Polarity Sensitive. Ensure proper Polarity before installation.
Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately
and contact an ABL representative for assistance.
Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.
Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing
of the unit.
Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.
Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15.
All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including interference that may cause undesired operation
CAUTION: RISK OF PRODUCT DAMAGE
Pre-Launch
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
3
Important Safety Instructions
This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic
devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio
equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment
operating between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit .www.acuitybrands.com
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
ABL LED General Warnings, Form No. 503.203
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
Maintenance should be performed by qualified person(s) familiar with the products' construction and operation and any hazards involved. Regular
maintenance programs are recommended.
DO NOT INSTALL DAMAGED PRODUCT! This product has been properly packed so that no parts should have been damaged during transit. Inspect to
confirm. Any part damaged or broken during or after assembly should be replaced.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Installation and service should be performed by a qualified licensed electrician.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with
installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the
purchaser's or owner's purposes, this matter should be referred to Acuity Brands Lighting, Inc.
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all
warnings and instructions included with and on the fixture box and all fixture labels.
Pre-Launch
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
4
Important Safety Instructions
Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please
visit .www.acuitybrands.com
ABL LED General Warnings, Form No. 503.203
© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
Wear gloves and safety glasses at all
luminaire from carton, installing, servicing or performing
maintenance.
Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF INJURY
times when removing Keep combustible and other materials
lamp/lens.
Do not operate in close proximity to
materials or substances affected by heat or drying.
CAUTION
RISK OF FIRE
that can burn, away from
persons, combustible
Allow lamp/fixture to cool before handling.
enclosure or light source.
Do not exceed maximum wattage marked on luminaire label.
Follow all manufacturer’s warnings,
and restrictions for: driver type, burning position, mounting
locations/methods, replacement and recycling.
WARNING
RISK OF BURN
Do not touch
recommendations
WARNING
RISK OF ELECTRIC SHOCK
Disconnect or turn off power before installation or servicing.
Verify that supply voltage is correct by comparing it with the
luminaire label information.
Make all electrical and grounded connections in accordance
National Electrical Code (NEC) and any applicable
All wiring connections should be capped with UL approved
connectors.
with the
local code requirements.
recognized wire
Pre-Launch
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
5
Important Safety Instructions
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please
visit .www.acuitybrands.com
Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.
© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
Electrostatic Discharge (ESD): ESD can damage product(s). Personal grounding equipment must be worn during all installation or servicing of
the unit.
Do not touch individual electrical components as this can cause ESD and affect product Performance.
Do not use product for anything other than its intended use.
Do not tamper with contacts.
If installing wiring systems: Materials and component parts of a manufacturing wiring system as described in Article 604 of the National Electric
Code and Underwriters Laboratories Standard for Safety #183 MUST BE installed.
Do not stretch or use cable sets that are to short or are of insufficient length.
Do not change or alter internal wiring or installation circuitry.
Do not modify the product.
If installing latching springs: ensure that the springs are fully engaged prior to moving to next connection.
CAUTION: RISK OF PRODUCT DAMAGE
Our BrandsIndoor/Outdoor Controls Daylighting
Lithonia Lighting DARK TO LIGHT SunOptics
Carandini LC&D
Holophane ROAM
RELOC
Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen Sensor Switch
Light Concepts
Indoor Lighting
Gotham
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting Synergy
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
6
A. Overview - Fixture
RIGHT SECTION (S2WDR / S4WDR)
INTERMEDIATE SECTION (S2WDI / S4WDI)
LEFT SECTION (S2WDL / S4WDL)
END CAP
SLOT 2/4
NOTE: Illustrations are used for reference only and can
differ slightly from the actual lighting system installed.
However, key components addressed in this information are
represented as accurately as possible.
Installation Instructions - Direct Wall S2PWD/S4PWD
Mounting Rail
Do not join fixtures together on the floor.
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
WARNING: DO NOT LOAD SINGLE FEED TO MORE
THAN 6 AMPS
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
SLOT 2/4
Installation Instructions - Direct Wall S2PWD/S4PWD
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
7
B. Overview Mounting
Individual Fixture Configurations Feed Hole
“A1” O.A.L
4’- 0 1/4”
5’- 0 1/4”
6’- 0 1/4”
7’- 0 1/4”
8’- 0 1/4”
“A2” O.A.L.
RUN LAYOUT (MOUNTING)
4’- 0”
5’- 0”
6’- 0”
7’- 0”
8’- 0”
“B”
3’- 1”
4’- 1”
5’- 1”
6’- 1”
7’- 1”
“C” FROM END “D”
5 3/4” 11
11
11
11
11"
5 3/4”
5 3/4”
5 3/4”
5 3/4”
Run Configurations
Intermediate (I) Right (R)Left (L)
LENGTH
2FT
3FT
4FT
5FT
6FT
7FT
8FT
“A” O.A.L
2’- 0 9/16"
3’- 0 9/16"
4’- 0 9/16"
5’- 0 9/16"
6’- 0 9/16"
7’- 0 9/16"
8’- 0 9/16"
“B” O.C.
INDIVIDUAL UNITS (MOUNTING)
1’- 1"
2’- 1"
3’- 1"
4’- 1"
5’- 1"
6’- 1"
7’- 1"
“C” FROM END
5 3/4”
5 3/4”
5 3/4”
5 3/4”
5 3/4”
5 3/4”
5 3/4”
IND FIXTURE
1-1/16” (distance from
bottom of mounted rail
and bottom of fixture)
Bottom of
Fixture
Bottom of
Mounting Rail
O.A.L - Overall lenght
O.C. - Distance from center to center
1 1/4"
2 3/4"
5 3/4"
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
8
C. Prep Fixtures and Parts
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
Mark as
Field
Order #
Section #
Unique Run/Pattern #
2.000 2.001 2.001 2.002
LEFT INTERMEDIATE RIGHTINTERMEDIATE
Each section is identified by and ID#.
Individual fixtures have whole number Y.
For replacement parts, provide ID# and order #.
Labels are located on the carton, on the fixture, and on the lens.
Section position starting with X.000 for the first fixture.
Same fixture configuration can carry identical ID# and are
interchangeable.
1
F-08-32FT
ID: 2.001
A427-40250-0-LLA-1.001
Mounting Hardware:
Mounting rails are attached to each fixture section. Unscrew the
mounting rails from the fixture to install rails to the wall first.
Mounting Hardware
2
Screw/Fasteners
(by others)
Flex Conduit
(by others)
2 x 4 J-Box
(by others)
Mounting Rail
(pre-attached to fixture)
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
2
2x4 J-box
(by others)
Stud
Screws
(by others)
Mounting Rail
Wall
D. Set Up Wall
At power feed locations:
Mount the J-box on the wall at distanced 5-13/16”
from the start of run. The center line of J-box and
luminaire run should align with each other.
Secure mounting rails for the first fixture per
pattern/row layout. Leave approximately 1-1/4” space
from edge of the wall to mount the rail for the first
section.
Note: Contractor should provide blocking behind wall
to adequately support fixture weight.
Level mounting rail to ensure proper mounting.
13
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
9
X - run Standard luminaire
Y - Center line of luminaire run
O - Intersection of X and Y axis
X
Y
O
5-13/16”
L = 3-3/4”
W = 1-9/16”
D = 1-1/2” Level
Mounting Rail
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
10
E. Mount Fixtures
Make wiring connections with wires from J-box.
All power connections should be installed according to local/national codes by a Certified Electrician.
1
SLOT 2/4
Black Hot
White Neutral
Green Ground
Purple Dimming
Dimming
Purple Dimming
WhitePurple Dimming
Orange Dimming
Dimming
Cap Purple Not Used
Not Used
Fixture Wire ColorOption
All
ZT
ECOD/ECOD5
DALI
NLIGHT, NLTAIR2
NODIM, ECOD2
Pink
Cap Pink
Cap Pink
Installation Instructions - Direct Wall S2WD/S4WD
Wall
J-box
Wiring
Connections
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
2
a. Slide top flange of mounting bracket underneath top flange of mounting rail.
b. Rotate fixture toward wall until bottom flange of the mounting bracket passes bottom flange of mounting
rail.
c. While supporting fixture, rest bottom flange of the mounting bracket on bottom flange of mounting rail.
d. Rotate fixture up toward wall and secure at mounting points with #8 screw provided.
AB C D
Mounting
Bracket
Flange
Mounting Rail
Top Flange
Fixture
Wall
Mounting Bracket
Bottom Flange
Mounting Bracket
Bottom Flange
Mounting Rail
Bottom Flange #8 Screw
Fixture Fixture
Wall
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
11
F. Opening Fixtures
21
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
Remove lens using appropriate tool (plastic putty knife recommended, or a similar
tool) by placing tool between cast end and lens. Do not use sharp metal objects as
a removal tool. Slowly pry lens away from fixture.
To remove the reflector unscrew four #8 screws.
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
Latch
Hook
Sliding Aligners (x2)
Detail "A"
Engage the latch to the hook by
pulling one end of the latch as shown
on detail "A". If DALI, Color is Orange
If ECODx, Color is Purple/White
12
G. Join Sections
1
Install (4x) aligner keys onto
one end of the run. The bump
on the aligner key should face
the extrusion. Half of the aligner
key should be exposed to insert
into the next section.
SLOT 2/4
Aligner Keys
Installed Position
Installation Instructions - Direct Wall S2WD/S4WD
(NOTE: Joining hardware parts provided in a separate red bag.)
Contractors Resources
p.18
Supplemental
p.14
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
Aligner Keys
a. Install (2x) slider aligners by sliding them into the appropriate slot on one end of the run.
b. Slide joining fixture while keeping aligner keys and sliding aligners aligned to the slots from opposite fixture body.
c. Fully join sections together (Detail "A" and Detail "B").
NOTE: Pull wires into the next section before fully joining fixture together. From each quick connector provided on the
intermediate ends of the fixture remove and discard the half (male or female) to which no wires are connected. Make
electrical connections with connectors.
Secure slider aligners with supplied #8
screws.
Make sure that groove on the slider
aligners is aligned with the junction line
of two fixtures.
Detail "B"
2
Close Fixtures
p.13
Click
Quick Connectors
See note below.
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
13
H. Close Fixtures
3
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
Gently push lens and snap it in into the housing.
NOTE: Use two people when working with fixtures
greater than 4 feet.
Insert reflectors into the housings. Secure reflectors with #8 screws.
Reflectors
#8 Screws
#8 Screws
21
Reflectors
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
14
I. Supplemental
SLOT 2/4
Battery Pack/Test Switch (E10WLCP):
a.If battery pack option is selected
(E10WLCP), then an un-switched normal
hot is required for power and sensing.
b. Standard battery drop is on the right
side of the section with the battery. See
above diagram for location of test button.
Test Button
Installation Instructions - Direct Wall S2WD/S4WD
For nLight option (NLIGHT):
Pull CAT5 cable through the knockout with the power cord and connect to the
nLight device within the fixture.
2
Knockout
CAT5 Cable
Power
Cord
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
1
nLight AIR
NOTE:
Install antenna on coax cable.
3
Coax Base
(pre-installed)
Antenna
(packaged with fixture)
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
15
I. Supplemental
Remote BGTD Mounting Option:
a. Suggested to mount in an accessible location for maintenance. To be installed
in ceiling or to structure according to local and NEC code.
b. 6 foot flexible conduit is attached. The remote BGTD should be mounted
within 6 feet of the J-box above the fixture.
2
Black Black
White White
Green Green
Output to Fixture Wiring
Output to
to
to
to
Fixture
White Normal Neutral
Blue Switched Line
Black
Orange
Green
(120v) Unswitched Line
(277v) Unswitched Line
Ground
Input # 2 Description
or or
Red Emergency Hot
White Emergency Neutral
Green Ground
Input # 1 Description
Normal Power
Emergency Power
Ground
Unused
1
Wires used to power EMPACK.
NOTE: Cap the unused wire at the junction box.
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
16
Continuous lens
J. Supplemental
Detail "Left (L)"
Continuous Lens Joining
Detail "Right (R)"
Housing
Continous lens
End cap
Lens orientation
1/8 "
a. Begin lens install per "Left (L)" detail.
b. Snap lens into fixture housing making sure to
follow "Lens Orientation" detail. Push left side of
lens end approximately 1/8" into end cap.
c. Unroll lens as you make your way through the run.
Snap the joiner into the extrusion and move
it to the previously installed continuous lens.
Tuck a new continuous lens into the joiner
cavity and continue with the installation.
d. Follow "Right (R)" detail for lens cutting. Cut lens
approximately 1/8" longer than last section housing
and tuck in right lens end into end cap cavity.
NOTE: Use at least two people when installing a
continuous lens.
NOTE: Continuous lens supplied oversized for any given run
lengh. Contractor to make final lenght cut at the time of
installation.
NOTE: Continuous lens should stay at room temperature for
a few hours before installation.
CONTINUOUS LENS TABLE
Fixture
run length
Supplied
continuous lens
length
2' - 8' 9'
9' - 16' 17'
17' - 24' 25'
25' - 32' 33'
33' - 40' 41'
40' + 41' + as requested
per run
Example:
65' supplied as: 41' and 25' lenghts
For run longer than 40', use a
joiner.
Right (R)
Intermediate (I)
Left (L)
1
Continuous lens joiner
Pre-Launch
Remove the cover where JB is using a flat head screw driver by
inserting it in designated tabs. Pull wires and wire it in JB to power the
fixture. Covers not in feed location should stay intact.
Bend tabs on the end as shown above for begining of the run and end of run (first and last
fixture). For intermediate fixtures remove tab by bending it and twisting as shown above on
the right.
2
1
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
17
Intermediate (I)
Wall Mounting Rails
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
J. Supplemental
Tab Bending Tab Removal
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-005
10/14, Rev B
18
K. Contractor’s Resources
SLOT 2/4
Installation Instructions - Direct Wall S2WD/S4WD
Contractors Resources
p.18
Supplemental
p.14
Close Fixtures
p.13
Join Sections
p.12
Mount First Fixture
p.10
Open Fixtures
p.11
Prep
p.8
Overview
p.6
Safety
p.1
Set Up Wall
p.9
Check out helpful programs, tools, installation videos and more.
SCAN ME
Pre-Launch
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Acuity Brands SLOT 4 User manual

Category
Floodlights
Type
User manual

Acuity Brands SLOT 4 is a versatile and energy-efficient LED lighting solution designed for commercial and industrial applications. With its sleek design and powerful illumination, SLOT 4 offers a range of features to meet your specific lighting needs.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI