  • Hello! I've reviewed the installation instructions for Mark Architectural Lighting's S2PI and S4PI indirect pendant lighting fixtures. This document provides comprehensive guidance on how to safely and correctly install these products, covering aspects such as mounting, electrical connections, and the use of nLight controls. I understand that these pendants are configurable for runs and lengths, and they include specific instructions for grid and hard lid ceilings. I'm familiar with the safety warnings and the procedure for joining fixtures, and I'm ready to assist with your questions.
  • Who should perform the installation of the luminaires?
    What should be done if a part is damaged during or after assembly?
    What precautions should be taken when handling luminaires?
    What should be done before connecting components?
Contractors Resources
p.18
Supplemental
p.17
1
SLOT 2/4 Installation Instructions - Indirect Pendant S2PI/S4PI
Important Safety Instructions
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit.
Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection
with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered
sufficiently for the purchaser's or owner's purposes, this matter should be referred to Acuity Brands Lighting, Inc.
It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum
light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household
detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above
manner, replacing damaged gaskets as necessary.
Maintenance of the luminaires should be performed by person(s) familiar with the luminaires' construction and operation and any hazards
involved. Regular fixture maintenance programs are recommended.
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please
read all warnings and instructions included with and on the fixture box and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Installation and service of luminaires should be performed by a qualified licensed electrician.
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Allow lamp/fixture to cool before handling.
enclosure or light source.
Do not exceed maximum wattage marked on luminaire label.
Follow all manufacturer’s warnings,
and restrictions for: driver type, burning position, mounting
locations/methods, replacement and recycling.
WARNING
RISK OF BURN
Do not touch
recommendations
WARNING
RISK OF ELECTRIC SHOCK
Disconnect or turn off power before installation or servicing.
Verify that supply voltage is correct by comparing it with the
luminaire label information.
Make all electrical and grounded connections in accordance
National Electrical Code (NEC) and any applicable
All wiring connections should be capped with UL approved
connectors.
with the
local code requirements.
recognized wire
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
2
SLOT 2/4
Important Safety Instructions
Wear gloves and safety glasses at all
luminaire from carton, installing, servicing or performing
maintenance.
Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF INJURY
times when removing Keep combustible and other materials
lamp/lens.
Do not operate in close proximity to
materials or substances affected by heat or drying.
CAUTION
RISK OF FIRE
that can burn, away from
persons, combustible
Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
Only use fixture in its intended location.
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility
with the luminaire prior to installation. LED fixtures must be powered directly o ffa switched circuit.
Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture.
Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
LED products are Polarity Sensitive. Ensure proper Polarity before installation.
Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately
and contact an ABL representative for assistance.
Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.
Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing
of the unit.
Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.
Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15.
All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including interference that may cause undesired operation
CAUTION: RISK OF PRODUCT DAMAGE
Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
3
SLOT 2/4
Important Safety Instructions
This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic
devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio
equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment
operating between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit .www.acuitybrands.com
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
ABL LED General Warnings, Form No. 503.203
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
Maintenance should be performed by qualified person(s) familiar with the products' construction and operation and any hazards involved. Regular
maintenance programs are recommended.
DO NOT INSTALL DAMAGED PRODUCT! This product has been properly packed so that no parts should have been damaged during transit. Inspect to
confirm. Any part damaged or broken during or after assembly should be replaced.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Installation and service should be performed by a qualified licensed electrician.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with
installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the
purchaser's or owner's purposes, this matter should be referred to Acuity Brands Lighting, Inc.
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all
warnings and instructions included with and on the fixture box and all fixture labels.
Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
4
SLOT 2/4
Important Safety Instructions
Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please
visit .www.acuitybrands.com
ABL LED General Warnings, Form No. 503.203
© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
Allow lamp/fixture to cool before handling.
enclosure or light source.
Do not exceed maximum wattage marked on luminaire label.
Follow all manufacturer’s warnings,
and restrictions for: driver type, burning position, mounting
locations/methods, replacement and recycling.
WARNING
RISK OF BURN
Do not touch
recommendations
Wear gloves and safety glasses at all
luminaire from carton, installing, servicing or performing
maintenance.
Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF INJURY
times when removing Keep combustible and other materials
lamp/lens.
Do not operate in close proximity to
materials or substances affected by heat or drying.
CAUTION
RISK OF FIRE
that can burn, away from
persons, combustible
WARNING
RISK OF ELECTRIC SHOCK
Disconnect or turn off power before installation or servicing.
Verify that supply voltage is correct by comparing it with the
luminaire label information.
Make all electrical and grounded connections in accordance
National Electrical Code (NEC) and any applicable
All wiring connections should be capped with UL approved
connectors.
with the
local code requirements.
recognized wire
Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
5
SLOT 2/4
Important Safety Instructions
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please
visit .www.acuitybrands.com
Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.
© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
Electrostatic Discharge (ESD): ESD can damage product(s). Personal grounding equipment must be worn during all installation or servicing of
the unit.
Do not touch individual electrical components as this can cause ESD and affect product Performance.
Do not use product for anything other than its intended use.
Do not tamper with contacts.
If installing wiring systems: Materials and component parts of a manufacturing wiring system as described in Article 604 of the National Electric
Code and Underwriters Laboratories Standard for Safety #183 MUST BE installed.
Do not stretch or use cable sets that are to short or are of insufficient length.
Do not change or alter internal wiring or installation circuitry.
Do not modify the product.
If installing latching springs: ensure that the springs are fully engaged prior to moving to next connection.
CAUTION: RISK OF PRODUCT DAMAGE
Our BrandsIndoor/Outdoor Controls Daylighting
Lithonia Lighting DARK TO LIGHT SunOptics
Carandini LC&D
Holophane ROAM
RELOC
Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen Sensor Switch
Light Concepts
Indoor Lighting
Gotham
Mark Architectural Light ing
Peerless
Renaissance Lighting
Winona Lighting Synergy
Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
6
SLOT 2/4
A. Overview - Fixture
HANGING BRACKET
GRIPLOCK
Adjustable cable grippers at
each support location
AIRCRAFT
CABLE
RIGHT SECTION (S2LIR / S4LIR)
INTERMEDIATE SECTION (S2LII / S4LII)
LEFT SECTION (S2LIL / S4LIL)
FEED CORD
END CAP
NOTE: Illustrations are used for reference only and can
differ slightly from the actual lighting system installed.
However, key components addressed in this information are
represented as accurately as possible.
Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
WARNING: DO NOT LOAD SINGLE FEED TO MORE
THAN 6 AMPS
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
7
SLOT 2/4
B. Overview - Mounting
C
Indirect, Dimming* or Non-Dimming
Indirect, nLight Controls (wired)
Non-Power Feed Point / Aircraft Cable
Power Feed
Battery Power Feed
CAT5
C
B
Feed Point Locations
* 2-Wire Dimming (ZT, DALI, and Lutron EcoSystem)
Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Left (L) Right (R)
Intermediate (I)
"A1" O.A.L. C" FROM END
4'- 0 1/4"
5'- 0 1/4"
6'- 0 1/4"
7'- 0 1/4"
8'- 0 1/4"
3/8"
3/8"
3/8"
3/8"
3/8"
"A2" O.A.L.
4'-0"
5'-0"
6'-0"
7'-0"
8'-0"
RUN LAYOUT (MOUNTING)
"B" O.C
3'- 11 15/16"
3'- 11 15/16"
3'- 11 15/16"
3'- 11 15/16"
3'- 11 15/16"
Run Configurations
"
INDIVIDUAL FIXTURES (MOUNTING)
A" O.A.L. "B" O.C "C" FROM END
2'- 0 9/16"
3'- 0 9/16"
4'- 0 9/16"
5'- 0 9/16"
6'- 0 9/16"
7'- 0 9/16"
8'- 0 9/16"
1'- 11 13/16"
1'- 11 13/16"
1'- 11 13/16"
1'- 11 13/16"
1'- 11 13/16"
1'- 11 13/16"
1'- 11 13/16"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
LENGTH
2FT
3FT
4FT
5FT
6FT
7FT
8FT
O.A.L. - Overall lenght
O.C. - Distance from center to center
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
8
SLOT 2/4 Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
C. Parts - Hanging Hardware
FEED KIT SUPPORT KIT
HARDWARE PLEASE OPEN FIRST”.
Provided in a separate red box labeled “INSTALLATION
All other parts for installation to be provided by others.
NOTE: Feed kit is the same for F1/F2 and parts are
provided for both types of ceiling install. See parts list on
this page for provided mounting hardware kit.
4
5
2
11
12
13
8
9
9
7
10
12
3
Grid Mount J-Box
*274WJ0
(provided with F1A option only)
Cross Bar
*274W1N
Grid Clip
*274W1R
Strain Relief
White: *274W1U
Black: *274W2L
5” Round Feed/CAT5 Canopy
White: *274WH1 (*274WJ7)
Black: *274WHG (*274WL5)
Silver: *2726W7 (*274WPA)
Mini Cable Gripper
*274W1J
5” Round Dual Feed Canopy
White: *274WLJ (*274WN0)
Black: *274WMP (*274WNY)
Silver: *274WPV (*274WR5)
Coupler (2” Canopy)
*274W24
5” Round Support Canopy
White: *274WK8 (*274WML)
Black: *274WLN (*274WMX)
Silver: *274WPJ (*274WR1)
Coupler (5” Canopy)
*274W2K
Aircraft Cable
36”: *274W2W
72”: *274W2G
150”: *274WH0
2” Round Support Canopy
White: *274W2S (*274WHC)
Black: *274WGX (*274WHL)
Silver: *274WLU (*274WNV)
Feed Cord (White)
4FT: *274WHN
7FT: *274WH7
14FT: *274WJE
Feed Cord (Clear)
4FT: *274WL9
7FT: *274WJA
14FT: *274WLY
1
2
3
4
5
6
7
8
9
10
11
12
13
* For square canopies, use part # in the parenthesis.
6
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
9
SLOT 2/4
2Bolt Bracket (A)
Bracket
(B)
T-Bar
Canopy
Coupler
Feed Locations:
a. Install J-box (by others) into the ceiling. Ensure
the bottom edge is flush with the ceiling. Connect the
metal conduit from building power to the J-box.
b. Mount the crossbar to the J-box using (2) #8
screws and fasten it securely to the J-box.
c. Insert strain relief to the feed cord.
d. Pass the feed cord through the hole in the canopy
and make wire connections inside J-box. Flush the
canopy with the crossbar and thread coupler onto
crossbar screw.
NOTE: A separate hole is provided for a CAT5 cable
if NLIGHT option is selected.
Non-Feed Locations (On-Grid):
a. Insert bolt into the bottom of bracket (A) and hook
onto grid member.
b. Hook bracket (B) onto bracket (A) and adjust
brackets to proper location along the ceiling grid and
push the tab from (A) towards bracket (B) to secure
brackets together.
c. Secure the brackets to the building structure per
local building codes.
Non-Feed Locations (Off-Grid):
a. Insert bolt into the bottom of bracket (A) and hook
together with bracket (B). Secure with nut (DO NOT
TIGHTEN).
b. Slide hanger onto caddy bar and fit caddy bar into
upper slots on the grid members.
c. Adjust brackets to proper location and push the
tab from bracket (A) towards bracket (B) to secure
brackets together.
d. Secure the brackets to the building structure per
local building codes.
D. Set Up Ceiling - Grid Ceilings (F1)
Bracket
Bracket
(A)T a b
(A)
Bracket
(B)
Installation Instructions - Indirect Pendant S2PI/S4PI
Cord
Feed
1 3
Hanger
Bracket (A)
Hanger
Bracket
(A)T a b
Hanger
Bracket
(B)
Strain
Relief
Cable Retainer
#8
Screws
Caddy Bar
(by others)
Feed
Cord
CAT5
Cable
Conduit
(by others)
J-Box (by others)
T-Bar
Cross-Bar
Canopy
Black
Green
White
Purple
Pink
Hot
Neutral
Ground
Dimming
Dimming
Caddy Bar
Brackets
(by others)
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
10
SLOT 2/4
E. Set Up Ceiling - Hardlid (F2)
Non-Feed Locations:
Secure 1/4-20 threaded rod approximately 3/8” to 5/8” below the ceiling. Insert
canopy and securely fasten the coupler.
Feed Locations:
a. Install the 4O J-box (by others) into the ceiling. Ensure the bottom edge is
flush with ceiling. Connect the metal conduit from building power to the J-box.
b. Mount crossbar to J-box using (2) #8 screws and fasten it securely to J-box.
c. Install strain relief to the feed cord.
d. Pass feed cord through the bushing in the canopy and make wire connections
inside J-box. Flush canopy with the crossbar and thread coupler onto the
crossbar screw.
NOTE: A separate hole is provided for CAT5 cable if NLIGHT option is selected.
Installation Instructions - Indirect Pendant S2PI/S4PI
Canopy
Ceiling
J-Box
(by others)
#8 Screws
Coupler
Ceiling
1/4-20
Threaded Rod
(by others)
1/4-20
Screw
Cross-Bar
Strain
Relief
Feed Cord
2
1
CAT5
Cable Feed
Cord
Black
Green
White
Purple
Pink
Hot
Neutral
Ground
Dimming
Dimming
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
11
SLOT 2/4
F. Prep Fixtures
Remove the wiring trays completely by removing screws from the side of
the tray and disconnect the wiring harness from the fixture.
Fixture
Screws
Wiring Tray
2
Installation Instructions - Indirect Pendant S2PI/S4PI
NOTE: Do not discard removed screws. Save to secure the trays back in
the fixture.
Mark as
Field
Order #
Section #
Unique Run/Pattern #
2.000 2.001 2.001 2.002
LEFT INTERMEDIATE RIGHTINTERMEDIATE
Each section is identified by and ID#.
Individual fixtures have whole number Y.
For replacement parts, provide ID# and order #.
Labels are located on the carton, on the fixture, and on the lens.
Section position starting with X.000 for the first fixture.
Same fixture configuration can carry identical ID# and are
interchangeable.
1
F-08-32FT
ID: 2.001
A427-40250-0-LLA-1.001
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
12
SLOT 2/4
G. Mount First Section
Grip Lock
Hardware
#8 Screw
Hanger Bracket
Grip
Lock
Aircraft
Cable
321
First Section:
a. Mount the grip lock from the hanging hardware kit
onto the screw provided on the fixture.
b. Adjust aircraft cable up or down, by pushing down
on upper lock cylinder. Once required length is
achieved, allow lock cylinder to spring back up. Make
sure the lock screw is tightened. Hide or trim the
excess cable length.
For an Individual Fixture:
Repeat the same procedure from step (1) on the
other end of fixture.
NOTE: For a run, refer to step 3.
For a Run:
a. Mount the grip lock onto the screw on the hanger
bracket and temporary secure in place with supplied
#8 screw.
b. Slide the hanger bracket into open end of
housing.
c. Adjust aircraft cable up or down, by pushing down
on upper lock cylinder. Once required length is
achieved, allow lock cylinder to spring back up. Make
sure the lock screw is tightened. Hide or trim the
excess cable length.
Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Grip Lock
Hardware
Screw
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
13
SLOT 2/4
H. Join Sections
Aligner Keys
2
1
Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
(NOTE: Joining hardware parts provided in a separate red bag.)
Detail "A"
a. Slide joining fixture over hanger bracket while keeping aligner keys aligned to the holes from opposite fixture body.
b. Fully join sections together, latch the hook and slide the hanger bracket into the next section (Detail "A").
NOTE: Pull wires into the next section before fully joining fixture together. From each quick connector provided on the
intermediate ends of the fixture remove and discard the half (male or female) to which no wires are connected. Make
electrical connections with quick connectors.
Install (4) aligner keys onto one end
of the run.
The bump on the aligner key should
face the extrusion. Half of the aligner
key should be exposed to insert into
the next section.
Hanger Bracket
Latch
Hook
Click
Quick Connectors
See note below.
Engage the latch to the hook by pulling one
end of the latch as shown on detail "A".
If DALI, Color is Orange
If ECODx, Color is Purple/White
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
14
SLOT 2/4
H. Join Sections
Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
(NOTE: Joining hardware parts provided in a separate red bag.)
Insert sliding joiners through slots at hanger bracket and
tighten with #8 screws provided.
Secure hanger bracket with #8 screws provided.
1 2
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
15
SLOT 2/4
I. Electrical Connections
Feed
Cable
Metal Strain Relief
Pliers
All power connections should be installed according to local/national codes by a Certified Electrician.
Cap
Make wiring connections.
NOTE: Emergency feed uses the exact same feed kit
and cord.
a. Pull the feed cable through grommet at the
beginning of the run.
b. Using pliers, compress the metal strain relief
on the power feed cable.
c. If NLIGHT option is selected, remove cap next
to the power cord, feed CAT5 cable through it,
and connect to the RJ45 port.
NOTE: Feed may come pre-installed if
pre-installed feed option was selected.
1 2 3
Installation Instructions - Indirect Pendant S2PI/S4PI
Black Hot
White Neutral
Green Ground
Purple Dimming
Pink Dimming
Purple Dimming
WhitePurple Dimming
Orange Dimming
Dimming
Cap Purple Not Used
Not Used
Fixture Wire ColorOption
All
ZT
ECOD/ECOD5
DALI
NLIGHT, NLTAIR2
NODIM, ECOD2
Cap Pink
Cap Pink
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Standard 18/5 Feed Cord
Normal Power
Emergency Power
Ground
Unused
Wires used to power EMPACK.
NOTE: Cap the unused wire at the junction box.
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
Secure reflectors with #8 screws.Insert reflectors into the housings.
16
SLOT 2/4
J. Close Fixtures
Gently push dust cover (if presented) and
snap it into the housing.
NOTE: Use two people when working with
fixtures greater than 4 feet.
Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
31 2
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
17
SLOT 2/4
K. Supplemental
21 3
Installation Instructions - Indirect Pendant S2PI/S4PI
Test Button
Battery Pack/Test Switch (E10WLCP):
a. If battery pack option is selected (E10WLCP),
then an un-switched normal hot is required for power
and sensing.
b. Standard battery drop is on the right side of the
section with the battery. See above diagram for
location of test button.
Dust Cover Removal (DC/DCF):
To remove, lift dust cover.
Feed Cable
nLight AIR
NOTE:
Install antenna on coax cable.
Antenna
(packaged with fixture)
Coax Base
(pre-installed)
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Pre-Launch
marklighting.com I 800-705-SERV (7378) I
T
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
I © 2022
AcuityBrands Lighting, Inc. All Rights Reserved.
912-00323-003
10/14, Rev A
18
SLOT 2/4
L. Contractor’s Resources
Installation Instructions - Indirect Pendant S2PI/S4PI
Contractors Resources
p.18
Supplemental
p.17
Close Fixtures
p.16
Join Sections
p.13
Mount First Fixture
p.12
Prep Fixtures
p.11
Set Up Ceiling
p.9
Parts
p.8
Overview
p.6
Safety
p.1
Electrical Connections
p.15
Check out helpful programs, tools, installation videos and more.
SCAN ME
Pre-Launch
/