Anova BH1831R-GT Installation guide

Type
Installation guide
anovafurnishings.com
888.535.5005 tel
TOOLS NEEDED: HARDWARE NEEDED:
Installation Instructions
Step-by-Step Installation Sequence
Product requires assembly before installation.
Examine the footing or slab for damage or defects. The footing or slab should be reinforced concrete rated at a
3,000 psi minimum and be cured for at least 28 days prior to the installation of the table.
CAUTION: Oversized holes and holes drilled too deep in the concrete will make it dicult to set the anchor.
!
Beacon Hill, Latitude, and Rendezvous Tables
3/8" SS or Rubber Washers
Match the amount of
anchors needed
3/8" Drop-in Anchors
(4) 3 & 4 Seat Tables
(5) 5 Seat Tables
(6) 6 Seat Table
3/8”-16 x 1” SS
Button Head Cap Screw
Match the amount of
anchors needed
Hammer Drill
Masonry Drill Bit Set
1/4" & 1/2"
3/8" Drop-in Anchor
Setting Tool
Hammer
Pencil
Allen Wrench Set
7/32"
Wire Brush
Level
Safety Glasses
Beacon Hill Latitude Rendezvous
Installation Instructions
Step-by-Step Installation Sequence
Beacon Hill, Latitude, and Rendezvous Tables
5
42
5
1.
2.
3.
5.
4.
6.
7.
8.
Place table in the desired location. Mark the location of the holes with a
pencil. To verify the alignment of the anchor markings you may reference
page 3.
It is recommended that you start holes in sequential order from the
smaller to the larger drill bits to avoid oversized holes or holes drilled too
deep. Begin with a 1/4" diameter drill bit followed by a 1/2" diameter bit.
Evacuate debris from mounting holes using compressed air and a steel wire
brush. This will create a clean environment for the anchor system.
Use the 3/8" drop-in anchor setting tool and
hammer to x the anchor into the drilled hole
by inserting the narrow end of the tool into the
anchor and giving it several hammer blows.
Insert one 3/8" drop-in anchor into the hole and use a hammer to tap the
anchor ush with the concrete.
Repeat steps 2 - 5 until all anchors are installed.
Align the mounting holes of the table over top of the anchors.
Care should be given to avoid rubbing the powder coating o the feet.
A 3/8" rubber washer is a suitable replacement option. Mount the table
to the anchors by fastening a button head cap screw and washer into each
anchor. Leave the hardware nger tight until all of them have been installed.
Verify that the table is level before tightening the anchors. Tighten all of the
hardware with a 7/32" Allen wrench.
!
!
7
8.28.1
NOTE: You can install anchors in all mounting holes locations, but it is not
necessary. On page 3 it is marked which hole locations we recommend you
install for 3 and 4 seat tables. For the 5 and 6 seat tables we recommend one
anchor for each seat on the same side every time.
Copyright 2019 ANOV Manufactured in the U.S.
Note: Please contact Customer Care at 1-866-797-1761 when ordering replacement parts.
Installation Instructions
FOOT MOUNTS:
01/17/2019
Beacon Hill, Latitude, and Rendezvous Tables
VIEW A-A
SCALE 0.08 : 1
FOOT MOUNT
A A
B B
1
1
2
2
3
3
4
4
A A
B B
C C
D D
SHEET
1
OF
1
DRAWN
CHECKED
QA
MFG
APPROVED
dirk 5/9/2011
DWG NO
L1444_SPEC-REV-B00
TITLE
SIZE
C
SCALE
REV
83.65
84.71
2.31
1.00
2.00
20.56
R23.00
46.00
1.94
1.50
2.38
17.82
18.10
(4 PLCS)
10.45
(4 PLCS)
20.90
(2 PLCS)
.41
(12 PLCS)
4.42
(2 PLCS)
30.35
18.88
3.83
(4 PLCS)
2.21
(4 PLCS)
SECTION A-A
SCALE 1:8
A A
1
1
2
2
3
3
4
4
A A
B B
C C
D D
SHEET 1 OF 1
DRAWN
CHECKED
QA
MFG
APPROVED
dirk 6/14/2011
DWG NO
L1447_FOOT_MOUNT
TITLE
SIZE
C
SCALE
REV
20.62
(2 PLCS)
14.98
(2 PLCS)
24.24
(2 PLCS)
7.88
(2 PLCS)
25.49
.41
(10 PLCS)
4.42
4.21
(2 PLCS)
1.37
(2 PLCS)
3.58
(2 PLCS)
2.60
(2 PLCS)
SECTION A-A
SCALE 1 : 14
A A
1
1
2
2
3
3
4
4
A A
B B
C C
D D
SHEET
1
OF
1
DRAWN
CHECKED
QA
MFG
APPROVED
dirk 7/13/2011
DWG NO
L1449_SPEC-REV-B01
TITLE
SIZE
C
SCALE
REV
93.04
93.04
46.00
1.94
20.63
1.00
2.00
22.08
34.40
30.35
18.93
22.52
(4 PLCS)
22.52
(4 PLCS)
.41
(8 PLCS)
4.42
(4 PLCS)
FOOT MOUNT
FOOT MOUNT
A A B B
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIRD ANGLE PROJECTION
TOLERANCES UNLESS NOTED:
X
1 X.X
.5 X.XX ± .25 X.XXX ± .125
X.XXXX ± .0625 X.XXXXX ± .03125
X.XXXXXX
.015625 ANGULAR ± 1°
ALL DIMENSIONS ARE IN INCHES AND ALL ANGLES
OR BENDS ARE 90
UNLESS OTHERWISE SPECIFIED
DO NOT SCALE DRAWING
PRINT IS FOR FABRICATION ONLY. ALL SURFACES
MAY EXPAND BY .125
.0625 DURING COATING.
211 North Lindbergh Blvd.
St. Louis, MO 63141
888.535.5005 tel
314.754.0835 fax
specify@anovafurnishings.com
anovafurnishings.com
DRAWN
LATITUDE TABLE 3 CONTOUR SEAT ADA
SIZE
CL1451_SPEC-REV-C02
DATE
7/9/2014
SCALE
1:14
SHEET
DWG NO
TITLE
C.O'HARA II
THIS DRAWING AND ALL THE INFORMATION CONTAINED HEREIN IS THE PROPERTY OF
ANOVA. DO NOT USE OR COPY WITHOUT WRITTEN PERMISSION.
THIS DRAWING IS CONFIDENTIAL AND IS SUBJECT TO RETURN ON DEMAND.
REV
1
OF
C02
1
THIS DRAWING IS FOR PROTOTYPE OR TOOLING
USE ONLY. DO NOT USE FOR PRODUCTION.
REV DESCRIPTION ECN TR.# DATE
C00 REDESIGN NONE 7/9/14
C01 ADDED SLAT SIZE & TUBE
DIAMETER NONE 7/11/14
C02 ADDED FOOT MOUNT VIEW NONE 11/16/18
30.15"
28.65"
20.29"
46.25Ø"
28.53"
69.77"
1.64"
UMBRELLA HOLE
.75"
20.88"
22.33"
93.29"
4.42"
1.94"
5.67"
.412X "
19.10"
34.60"
2.25"
2.38Ø"
4.42"
(3 PLCS)
22.52"
(2 PLCS)
22.52"
(2 PLCS)
.41"
(6 PLCS)
22.52"
(2 PLCS) 22.52"
(4 PLCS)
22.52"
(4 PLCS)
22.52"
(2 PLCS)
4.42"
(3 PLCS)
4.42"
4.42"
(6 PLCS)
4.42"
(4 PLCS)
Ø.41"
(6 PLCS)
Ø.41"
(8 PLCS)
20.62"
(2 PLCS)
14.98"
(2 PLCS)
24.24"
(2 PLCS)
7.88"
(2 PLCS)
25.49"
Ø.41"
(10 PLCS)
18.10"
(4 PLCS)
10.45"
(4 PLCS)
20.90"
(2 PLCS)
Ø.41"
(12 PLCS)
3 Seat Tables
5 Seat Tables
4 Seat Tables
6 Seat Tables
Anchors 2 & 3
Anchor 1
Anchor 1
Anchor 2
Anchor 3
Anchor 4
Anchor 4
1.37"
(2 PLCS)
4.21"
(2 PLCS)
2.21"
(2 PLCS)
3.83"
(2 PLCS)
2.60"
(2 PLCS)
3.58"
(2 PLCS)
  • Page 1 1
  • Page 2 2
  • Page 3 3

Anova BH1831R-GT Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI