STEERING
CONTROL
Tiller group for remote and ovverride operation
2
3431E/105--301.DOC022
Edition: March 16, 2007
Warning messages
Warning messages occur if the remote FU tiller (dual) is activated without previously activating tiller control, which means
that steering control is ineffective from this tiller.
Steering
mode selector
Indications Confirmation/reaction
Comments
Notes
¡ Steering mode selector to AUTO
Active
Standby
Version a:
Active
Standby
Version b:
yellow
or
Does not apply to Autopilot Override Tiller!
When the tiller is moved
pulsed audible warning signal
See section 4 of the relevant device description
for versions a and b.
© Steering mode selector to REMOTE – tiller in STANDBY
Active
Standby
yellow
Active
Standby
Autopilot Override Tiller:
or
When the tiller is moved
pulsed audible warning signal
¢ Steering mode selector to NFU
Active
Standby
Active
Standby
Autopilot Override Tiller:
or
When the tiller is moved
pulsed audible warning signal
£ Steering mode selector to FU
Active
Standby
Active
Standby
Autopilot Override Tiller:
or
When the tiller is moved
pulsed audible warning signal
Faulty operation
When an alarm occurs: ; acknowledge alarm with
the audible alarm stops, the LED is permanently illuminated until the fault is rectified
No
.
indication Meaning
Likely
cause
Effect on oper-
ation
Measures to take
1 BG bus error
*)
-- Short circuit
-- faulty cable
-- faulty tiller
The tiller cannot be
used
-- Switch steering mode selector from ‘Auto’
or‘Remote’to‘FU’orNFU
-- Check the cable connection
-- Disconnect the faulty device from the bus
2 Steering failure Steering control
faulty See also
sections of the
manual entitled
“faulty operation” or
“Troubleshooting”
The tiller cannot be
used
-- Switch steering mode selector from ‘Auto’
or ‘Remote’ to ‘MANUAL’
-- See also sections in manual
“entitled “Faulty Operation” or
“Troubleshooting”
-- Check RdSpeed at the Autopilot
-- Inform Raytheon Anschütz
3 Tiller fault (Rudder
adjustment only for
Tiller 105-301,
105-303 and
105-304)
Defect in bus tiller The tiller cannot be
used
-- Switch steering mode selector from ‘Auto’
or‘Remote’to‘FU’orNFU
-- Change tiller control point
4 Configuration
fault
-- Incorrect value
-- Values outside
validrange
Values not adopted,
but bus tiller
operation is not
disturbed
Check the configuration
(see service manual)
5 For dual follow-up
devices the second
device for
independent
operation is
missing
-- The second
device is
incorrectly
configured
-- The second
device is not
connected
Independent
operation not
possible
Only synchronous steering
possible!
Check bus connection to second device
6 EEPROM
faulty
Faulty EEPROM The tiller cannot be
used
-- Switch steering mode selector from ‘Auto’
or‘Remote’to‘FU’orNFU
-- Change tiller control point
-- Inform Raytheon Anschütz
7 Unknown tiller type Hardware fault Tiller not operating -- Switch steering mode selector from ‘Auto’
or‘Remote’to‘FU’orNFU
-- Change tiller control point
-- Inform Raytheon Anschütz
8 No tiller telegrams -- No bus
connection
-- Faulty device
The tiller cannot be
used
-- Switch steering mode selector from ‘Auto’
or‘Remote’to‘FU’orNFU
-- Change tiller control point
-- Check bus connection (check data cable)
-- Inform Raytheon Anschütz
*)
specific to Raytheon Anschütz
and
red