Raytheon Remote FU-Tiller (dual), Type 105-304 Operating instructions

Type
Operating instructions
Raytheon Anschütz GmbH
Postfach 1166
D -- 24100 Kiel
Germany
Tel+49--431--3019--0
Fax+49--431--3019--501
www.raytheon --anschuetz.de
3434E/105--304.DOC012 Edition: 15 Aug 00
Revision: 22. January 2003
Revision: March 16, 2007
Remote
FU Tiller (dual)
Type 105 -- 304
Operating instructions
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung
und
Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich
zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz.
Copying of this document, and giving it to others and the use or
communication of the contents thereof, are forbidden without
express
authority. Offenders are liable for payment of damages.
Toute communication ou reproduction de ce document, toute
exploitation ou communication de son contenu sont interdites, sauf
autorisation expresse. Tout manquement à cette règle est illicite et
expose son auteur au versement de dommages et intérêts.
Sin nuestra expresa autorización, queda terminantemente
prohibida la
reproducción total o parcial de este documento, así como su uso
indebido y/o su exhibición o comunicación a terceros. De los
infractores
se exigirá el correspondiente resarcimiento de daños y perjuicios.
STEERING
Remote FU Tiller (dual)
CONTROL
Operating instructions
I
3434E/105--304.DOC012Edition: 22. January 2003
TABLE OF CONTENTS Page
1 General 1...............................................................
2 Remote FU Tiller (dual) in Steering Control System 2........................
3 Notes to operating instructions 3...........................................
4 Switching on 4..........................................................
4.1 General 4...............................................................
5 Standard operation 5.....................................................
6 Additional controls in standard operation 7..................................
6.1 Illumination control 7.....................................................
6.2 Testing 9...............................................................
6.3 Warning messages 11.....................................................
7 Faulty operation 13.......................................................
Annex: Control and display devices
Remote FU Tiller (dual)
Operating instructions
3434E/105--304.DOC012
II
Edition: 15 Aug 00
STEERING
CONTROL
Remote FU Tiller (dual)
Operating instructions
1
3434E/105--304.DOC012Edition: 15 Aug 00
1 General
The remote FU tiller (dual) is used on the bridge to steer a course and is installed at the vessel
control panel or navigating stand (
F OLLOW U P). Two remote FU tillers are needed at all
times to act as dual tillers for twin rudder equipment with separate rudder blade control.
Either of two operating modes SYNCHRONOUS or INDEPENDENT -- may be selected.
The scale graduation is ± 35 ° , as standardand the control knob deflection angle is ± 60 °. The
control knob is slightly engaged when it is at the mechanical zero position. The scale is
illuminated.
In order to change the rudder angle (e.g. to starboard) turn the control knob clockwise.
The effect on steering is similar to that of a hand wheel.
Operating instructions
These operating instructions contain every operational procedure as well as information about
behaviour when alarms occur. Such alarms are indicated on the digital display units and also by
means of flashing LEDs and audible alarm signals.
Service manual
In addition to the operating manual, there is also a service manual. It contains the following:
-- Information relating to installation and initial start-up
-- Information relating to maintenance and repairs, and
-- a description of the tiller
Remote FU Tiller (dual)
Operating instructions
2
3434E/105--304.DOC012 Edition: 15 Aug 00
2 Remote FU Tiller (dual) in Steering Control system
Remote FU tillers (dual) are bus users on the user device bus (BG bus)
*)
on the NP 2000
autopilot control transmitter within a secondary steering system.
The remote FU tiller (dual) is activated by setting the steering mode selector either to the
REMOTE or the AUTO/REMOTE setting (see figure). The bus transfers the control signals,
and the NP2000 Autopilot Control Unit converts these into analogue control signals for the FU
amplifier.
The control point and operating mode (SYNCHRONOUS or INDEPENDENT) can be selected
on site. The selection is made according to the “Take Over” principle, i.e. only one control point
is active for SYNCHRONOUS operation, and both are active for INDEPENDENT operation.
A total of 15 bus users can be connected.
Port wing
BG--Bus
*)
NP 2000 Autopilot
FU Tiller Dual 1
(rudder 1)
FU--Tiller Dual 2
(rudder 2)
Steering
mode selector
Remote
Max. 15 bus users
168.5
FU amplifier
analogue
set rudder
value signal
*)
specific to Raytheon Marine
Rudder 1 Rudder 2
Auto/Remote
Remote FU Tiller (dual) in Steering Control system
STEERING
CONTROL
Remote FU Tiller (dual)
Operating instructions
3
3434E/105--304.DOC012Edition: 15 Aug 00
3 Notes to operating instructions
The system operates interactively (i.e. an action causes a reaction).
Each operating procedure shown must be completed step by step. Where necessary and in the
relevant sections, we have added useful supplementary notes alongside the illustrations
(symbols).
We recommend that you fold out the appendix page since it contains an illustration of all the
controls and indications.
Explanation of the symbols used.
press a key
LED off
LED on
LED flashing
audible signal on
audible signal off
Remote FU Tiller (dual)
Operating instructions
4
3434E/105--304.DOC012 Edition: 15 Aug 00
4 Switching on
When the full rudder control system is switched on, the remote FU tillers (dual) are also
ready for operation in REMOTE or in AUTO/REMOTE mode.
4.1 General
indications Comments
Notes
red
For example:
The display is indicating the c urrent rudder
angle in ° , the relevant LED is illuminated.
If the final decimal point of the indicated figure
is illuminated, this means that an additional
0.5 ° is being indicated. In the example: 10,5°
Rudder position is indicated by illuminating the
relevant LED (PORT is red, STBD is green).
Both LEDs remain unlit when the rudder posi-
tion is 0 °
It is possible to have two different system configurations.
a) The FU tiller can only be used in REMOTE operating mode.
b) In AUTO/REMOTE operation mode, it is possible to switch between FU
tiller and autopilot operation without activating the steering mode selector.
STEERING
CONTROL
Remote FU Tiller (dual)
Operating instructions
5
3434E/105--304.DOC012Edition: 15 Aug 00
5 Standard operation
Indications Comments
Notes
¡ Tiller in Standby
Version a:
Synchronous
Active
Standby
yellow
Independent
Set steering mode selector to REMOTE
After switching to REMOTE the
rudder is s teered manually by
means of the hand wheel until a
tiller is activated.
The ‘standby’ LED beside the
Active/Standby key is illuminated
Version b:
Active
Standby
yellow
Synchronous
Independent
Steering mode selector is set to
AUTO/REMOTE
After switching to AUTO/REMOTE
The rudder is steered manually by
means of the hand wheel until a
tiller is activated.
The ‘standby’ LED beside the
Active/Standby key is illuminated
© Activating the tiller for ‘Synchronous’ operation
Active
Standby
Active
Standby
red
For example:
green
Tiller Steering
Autopilot:
Synchronous
Independent
green
Press the Active/Standby key
An audible signal sounds when the switch is
made
The ‘Synchronous’ LED is illuminated green.
When the tiller is activated
‘Synchronous’ operation is always
selected.
The active tiller controls both
rudders.
The ‘Active’ L ED beside the key is illuminated
green
The line of text on the autopilot control unit
indicates manual steering.
Turn the knob to set the required rudder angle.
This adjusts both rudders.
The display unit indicates the actual rudder
angle in ° and the relevant LED is illuminated.
Remote FU Tiller (dual)
Operating instructions
6
3434E/105--304.DOC012 Edition: 15 Aug 00
Indications Comments
Notes
¢ Activating the tiller for ‘Independent’ operation
Active
Standby
red
green
Tiller Steering
Autopilot:
Synchronous
Independent
green
red
Rudder 1
Rudder
2
For example:
Once the procedure © has been executed:
press the key
An audible signal sounds when the switch is
made.
The ‘Independent’ LED is illuminated green.
Both the tillers are now active.
The ‘Active’ LED beside the key continues to
be illuminated green.
The line of text on the autopilot control unit
continues to indicate manual steering.
Turn the knob for Tiller 1 to the required rudder
angle for rudder 1.
Turn the knob for Tiller 2 to the required rudder
angle for rudder 2.
The display unit indicates the actual rudder
angle in ° and the relevant LED is illuminated.
£ Switching from ‘Independent’ to ‘Synchronous’ operating mode
STEERING
CONTROL
Remote FU Tiller (dual)
Operating instructions
7
3434E/105--304.DOC012Edition: 15 Aug 00
Indications Comments
Notes
Active
Standby
green
Tiller Steering
Autopilot:
Synchronous
Independent
green
Active
Standby
yellow
press the key again
An audible signal sounds when the switch is
made
The tiller to which the switch has just
been made changes to
‘Synchronous’, and the second
tiller changes automatically from
‘Active’ to ‘Standby’.
The ‘Synchronous’ LED is illuminated green.
The second rudder adopts the rudder
position of the synchronous tiller that
has just been activated.
The ‘Active’ L ED beside the key for the tiller
that has been switched on continues to be
illuminated green .
The ‘Standby’ LED on the other tiller is
illuminated yellow.
The line of text on the autopilot control unit
continues to indicate manual steering.
Continue as for procedure ¢
¤ Deactivating the tiller
Active
Standby
yellow
Heading
Control
Autopilot:
other tiller
Active
Standby
yellow
1. Switch the steering mode selector to main
FU steering system or NFU
or
2. Return control system to autopilot:
Activate a function key (e.g. HEADING
CONTROL) on the autopilot
(see system configuration)
or
3. activate another tiller
The ‘Standby’ L ED beside the deactivated tiller
is illuminated yellow.
Remote FU Tiller (dual)
Operating instructions
8
3434E/105--304.DOC012 Edition: 15 Aug 00
6 Additional operation in standard operation
6.1 Illumination control
Indications Comments
Notes
Increases the brightness on all LEDs and Indications.
Decreases the brightness on all LEDs and Indications.
STEERING
CONTROL
Remote FU Tiller (dual)
Operating instructions
9
3434E/105--304.DOC012Edition: 22. January 2003
6.2 Testing
Indications Comments
Notes
simultaneous
For
example:
For
example:
For
example:
or
For
example:
or
Locations:
Pn = Port Wing
Sn = Starboard Wing
br = Bridge (1)
bb = Bridge (2)
Automatic test cycle lasting approx. 30s.
Approx. 2 second check of
-- 7 segment display
-- Audible signal (twice)
-- LEDs to maximum brilliance
-- Key illumination to maximum brilliance
The following indications are then tested:
-- Tiller type Dual FU PORT (dP) and
Dual FU STBD (dS)
-- Bridge allocation
For example: Tiller on bridge 1 (b1)
-- Group to which it belongs
Forexample:Group1(G1)
-- Rudder scale in two s teps
-- Indication (rS)
-- Rudder scale value
For example: 35 °
-- Software version in two steps
-- E
-- 00.
-- 0 0
-- Indication of installation--position (also in
case of external control)
Fr = External control possible
(External control must not be
installed)
Po = Position
---- = not already adjusted
Remote FU Tiller (dual)
Operating instructions
10
3434E/105--304.DOC012 Edition: 15 Aug 00
Indications Comments
Notes
For
example:
-- The DP address in two steps
-- Bus user address (Ad)
-- Va l u e e . g . 5
-- Current status of bus termination
e.g. RS485 interface is not terminated
(’t1’ is terminated)
For
example:
-- The EPROM checksum in three steps,
e.g. A3 E6
-- Check sum (CH)
-- upper hexadecimal value
-- lower hexadecimal value
When the test has ended the display automati-
cally reverts to indicating the rudder position
STEERING
CONTROL
Remote FU Tiller (dual)
Operating instructions
11
3434E/105--304.DOC012Edition: 15 Aug 00
6.3 Warning messages
Warning messages occur if the remote FU tiller (dual) is activated
without previously activating tiller control, which means that steering
control is ineffective from this tiller.
Indications Comments
Notes
¡ Steering mode selector to AUTO
Active
Standby
Version a:
Version b:
Active
Standby
yellow
Steering mode selector is set to ‘Auto’
Version a (see section 4):
Neither LED (ACTIVE or STANDBY) is lit.
Version b (see section 4):
The STANDBY LED is illuminated
When the tiller is moved
a pulsed audible warning signal (5 separate
tones) sounds.
© Steering mode selector to REMOTE tiller in STANDBY
Active
Standby
Steering mode selector is set to ‘Remote.
The STANDBY LED is illuminated.
When the tiller is moved
a pulsed audible warning signal (5 separate
tones) sounds.
¢ Steering mode selector to NFU
Active
Standby
Steering mode selector is set to ‘NFU’
Neither LED (ACTIVE or STANDBY) is lit.
When the tiller is moved
a pulsed audible warning signal (5 separate
tones) sounds.
Remote FU Tiller (dual)
Operating instructions
12
3434E/105--304.DOC012 Edition: 15 Aug 00
Indications Comments
Notes
£ Steering mode selector to FU
Active
Standby
Steering mode selector is set to ‘FU’
Neither LED (ACTIVE or STANDBY) is lit
When the tiller is moved
a pulsed audible warning signal (5 separate
tones) sounds.
STEERING
CONTROL
Remote FU Tiller (dual)
Operating instructions
13
3434E/105--304.DOC012Edition: March 16, 2007
7 Faulty operation
Behaviour when alarms occur:
-- When an alarm occurs:
-- Acknowledge alarm by pressing The audible alarm stops, the LED is
illuminated.
The light remains on permanently
until the fault is rectified
-- Steering mode selector to AUTO
No Indication Meaning Likely
cause
Effect on
operation
Measures to take
1 BG bus error
8)
-- Short circuit
-- Faulty cable
-- Faulty tiller
The tiller cannot be
used
-- Switch steering mode selector from
‘Auto’ or ‘Remote’ to ‘FU’ or NFU
-- Check the cable connection
-- Disconnect the faulty device from
the bus
2 Steering failure Steering control
faulty
Reference para-
meters for set rud-
der turning rate not
set correctly
The tiller cannot be
used, if the rudder
does not follow the
set values
The tiller can be
used if it is only the
monitoring para-
meter that is incor-
rectly adapted
-- Set steering mode selector to
MANUAL
-- Inform Raytheon Anschütz
-- Set steering mode selector to
MANUAL
-- Adapt the parameter
check parameter RdSpeed
(adjustable at the Autopilot)**
-- Inform Raytheon Anschütz
3 Tiller fault Defect in bus tiller The tiller cannot be
used
-- Switch steering mode selector from
‘Auto’ or ‘Remote’ to ‘FU’ or NFU
-- Change tiller control point
4 Configuration
fault
-- Incorrect value
-- Values outside
valid range
Values not
adopted, although
bus tiller operation
is not defective
Check the configuration
(see service manual)
*)
specific to Raytheon Anschütz
**) Rudderturning rate not correct adjusted (parameter setting “1” at the Autopilot meets a rate of 1°/s). If the
error E2 occurs an adjustment of either “0” or a higher setting than “1” for RdSpeed (Rudder Speed) must be
selected System configuration, Operator Unit Autopilot.
and
red
Remote FU Tiller (dual)
Operating instructions
14
3434E/105--304.DOC012 Edition: 15 Aug 00
No Indication Meaning Likely
cause
Effect on
operation
Measures to take
5
1*)
For Dual Follow-up
devices the second
device for Indepen-
dent operation is
missing
-- The second
device is
incorrectly
configured
-- The second
device is not
connected
Independent oper-
ation not possible
Only synchronous steering
possible!
Check bus connection to second
device
6
EEPROM
faulty
Faulty EEPROM The tiller cannot be
used
-- Switch steering mode selector from
‘Auto’ or ‘Remote’ to ‘FU’ or NFU
-- Change tiller control point
-- Inform Raytheon Anschütz
7
Unknown tiller type Hardware fault Tiller not operating -- Switch steering mode selector from
‘Auto’ or ‘Remote’ to ‘FU’ or NFU
-- Change tiller control point
-- Inform Raytheon Anschütz
8
No tiller telegrams -- No bus
connection
-- Faulty device
The tiller cannot be
used
-- Switch steering mode selector from
‘Auto’ or ‘Remote’ to ‘FU’ or NFU
-- Change tiller control point
-- Check bus connection
(check data cable)
-- Inform Raytheon Anschütz
1*) Once alarms E2 and E5 have been acknowledged the display reverts to standard
rudder position display, so that the rudder position can continue to be adjusted.
The luminous alarm diode changes from flashing to permanently lit and remains
illuminated until the fault has been rectified.
The error code can be retrieved by pressing the alarm key at any time while the
displayisactive.
STEERING
CONTROL
Remote FU Tiller (dual)
Operating instructions
Annex1
3434E/105--304.DOC012Edition: 15 Aug 00
FU Tiller
Control and display devices
PORT LED
(red)
STBD LED
(green)
7 segment indicator
actual indication in °
current parameter
Alarms
Alarm signal
and acknowledgement
(red LED)
set rudder in °
PORT figures in red
STBD figures in green
FU
control knob:
Brightness control
infinitely variable brightness control
Testing
a check is made of
-- the 7 segment indicator
-- the audible alarm
-- the LEDs to maximum brightness
-- Key illumination to
maximum brightness
-- current parameters
Tiller activation
‘Tiller active’ LED
(green)
‘Tiller Standby’ LED
(yellow)
-- D u a l --
Indicator for
synchronous operation and
LED indicator (green)
Indicator for
Independent operation and
LED indicator (green)
Switch from:
-- synchronous to
Independent
-- Independent to
Synchronous
STEERING
CONTROL
Tiller group for remote and override operation
1
3434E/105--304.DOC022Edition: 22. January 2003
Short-form operating instructions
Tiller type
Steering
mode selector
Activation and operation Indication Deactivation Comments
Remote
NFU Tiller
Type 105 -- 300
V
e
r
s
i
o
n
a
:
Active
Standby
yellow
Active
Standby
green
see description no. 3430E/105--300.DOC012
Remote
FU Tiller
Type 105 -- 301
V
e
r
s
i
o
n
a
:
Active
Standby
yellow
Active
Standby
green
green
r
e
d
10° STBD
e.g.
e.
g
.
1. Switch steering mode selector
to main FU steering system
or NFU
or
2
c
o
n
t
r
o
l
s
y
s
t
e
m
r
e
t
u
r
n
e
d
t
o
A
u
t
o
p
i
l
o
t
:
A
f
t
e
r
s
w
i
t
c
h
i
n
g
t
o
R
E
M
O
T
E
o
r
see description no. 3431E/105--301.DOC012
Remote FU Tiller
(Dual)
Type 105 -- 304
Two devices required
Version b:
Active
Standby
yellow
Active
Standby
green
Synchronous
green
Independent
green
Synchronous
green
Both rudders One rudder only Both rudders
red
10° PORT
Rudder position 0°
e
.
g
.
Tiller Steering
Autopilot:
red
10,5° PORT
e.g.
2. control system returned to
autopilot: activate a function
key (e.g. HEADING
CONTROL) on the autopilot
(system configuration)
or
3. activate another tiller
Active
Standby
yellow
Heading
Control
utop
ot:
other tiller
A
f
t
er sw
i
t
c
h
i
ng
t
o
R
E
M
O
T
E
or
AUTO/REMOTE on the steering mode
selector the rudder is steered
manually until a tiller is activated.
see description no. 3434E/105--304.DOC012
Autopilot Override
NFU Tiller
Type 105 -- 302
Standby
yellow
Active
green
g
A
u
t
o
p
il
o
t
:
1. Switch steering mode selector
to main FU steering system
or NFU
Neither LED is lit
or
see description no. 3432E/105--302.DOC012
Autopilot Override
FU Tiller
Type 105 -- 303
Standby
yellow
Active
green
Override
A
u
t
o
p
i
l
o
t
:
o
r
2. press the AUTO key
Steering control is taken over by
the autopilot
Auto
see description no. 3433E/105--303.DOC012
Dimming
Infinitely variable
brightness control
for all LEDs and
indicators.
or
Test
For example:
For example:
For example:
for FU Tiller
(dual) only
simultaneous
For
example:
Tiller type Assignment of
bridge
Group to which
it belongs
Rudder scale Software version
DP address
For
ex.:
Bus termination
For example:
Check sum
For
example:
t1 = terminated
t0 = not terminated
For
example:
Automatic testing cycle
lasting approx. 30s
-- 7 segment
-- audible signal
-- L E D s
-- key illumination
indicator
Position
f. example:
Fr=Remote control
Po=Position
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Raytheon Remote FU-Tiller (dual), Type 105-304 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI