Supermicro 8042-8 User manual

Category
Server barebones
Type
User manual

This manual is also suitable for

®
SUPERSERVER 8042-8
SUPERSERVER 8042-6
USER’S MANUAL
1.0a
SUPER
S
UPERMICR
ALARM
RESET
R
The information in this User’s Manual has been carefully reviewed and is believed to be
accurate. The vendor assumes no responsibility for any inaccuracies that may be
contained in this document, makes no commitment to update or to keep current the
information in this manual, or to notify any person or organization of the updates.
Please
Note: For the most up-to-date version of this manual, please see our
web site at www.supermicro.com.
SUPERMICRO COMPUTER reserves the right to make changes to the product described in
this manual at any time and without notice. This product, including software, if any, and
documentation may not, in whole or in part, be copied, photocopied, reproduced, translated
or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT,
SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM
THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, THE VENDOR
SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED
OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING,
INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR
DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of
Santa Clara County in the State of California, USA. The State of California, County of
Santa Clara shall be the exclusive venue for the resolution of any such disputes.
Supermicro's total liability for all claims will not exceed the price paid for the hardware
product.
Unless you request and receive written permission from SUPER MICRO COMPUTER, you
may not copy any part of this document.
Information in this document is subject to change without notice. Other products and
companies referred to herein are trademarks or registered trademarks of their respective
companies or mark holders.
Copyright © 2003 by SUPER MICRO COMPUTER INC.
All rights reserved.
Printed in the United States of America
iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC techni-
cians. It provides information for the installation and use of the Super-
Server 8042-8/8042-6. Installation and maintainance should be performed
by experienced technicians only.
The SuperServer 8042-8/8042-6 is a high-end, quad processor 4U
rackmount server based on the SC862 4U rackmount server chassis and
the P4QH8/P4QH6, a quad processor serverboard that supports Intel Xeon
®
processors MP of up to 2.8 GHz at a Front Side (system) Bus speed of 400
MHz and up to 32 GB of DDR200 (PC1600) SDRAM main memory.
Manual Organization
Chapter 1: Introduction
The first chapter provides a checklist of the main components included with
the server system and describes the main features of the SUPER P4QH8/
P4QH6 serverboard and the SC862 chassis, which make up the Super-
Server 8042-8/8042-6.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer
8042-8/8042-6 into a rack and check out the server configuration prior to
powering up the system. If your server was ordered without processor
and memory components, this chapter will refer you to the appropriate sec-
tions of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions
and information provided by the control panel on the chassis as well as
other LEDs located throughout the system.
Chapter 7 includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A offers information on BIOS POST messages.
Appendix B provides POST codes.
Appendix C lists the system specifications.
SUPERSERVER 8042-8/8042-6 Manual
iv
v
Preface
Notes
vi
Table of Contents
Preface
About This Manual ....................................................................................................... iii
Manual Organization .................................................................................................... iii
Chapter 1: Introduction
1-1 Overview ............................................................................................................ 1-1
1-2 Serverboard Features ...................................................................................... 1-2
1-3 Server Chassis Features ................................................................................ 1-4
1-4 Contacting Supermicro ................................................................................... 1-6
Chapter 2: Server Installation
2-1 Overview ............................................................................................................ 2-1
2-2 Unpacking the SuperServer 8042-8/8042-6................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
2-4 Installing the 8042-8/8042-6 into a Rack...................................................... 2-3
2-5 Checking the Serverboard Setup ................................................................... 2-7
2-6 Checking the Drive Bay Setup....................................................................... 2-9
Chapter 3: System Interface
3-1 Overview ............................................................................................................ 3-1
3-2 Control Panel Buttons..................................................................................... 3-1
Power ......................................................................................................... 3-1
Alarm.......................................................................................................... 3-1
Reset.......................................................................................................... 3-1
3-3 Control Panel LEDs......................................................................................... 3-2
Power ......................................................................................................... 3-2
NIC.............................................................................................................. 3-2
HDD ............................................................................................................ 3-2
PWR Fault ................................................................................................. 3-2
Fan Fail........................................................................................................3-3
Overheat ..................................................................................................... 3-3
SCA Channel ............................................................................................. 3-3
3-4 SCSI Drive Carrier LEDs................................................................................. 3-4
3-5 Power Supply LEDs ........................................................................................ 3-4
SUPERSERVER 8042-8/8042-6 Manual
Chapter 4: System Safety
4-1 Electrical Safety Precautions...........................................................................4-1
4-2 General Safety Precautions .............................................................................4-2
4-3 ESD Precautions ...............................................................................................4-3
4-4 Operating Precautions ......................................................................................4-4
Chapter 5: Advanced Serverboard Setup
5-1 Handling the P4QH8/P4QH6 Serverboard .......................................................5-1
5-2 PGA Processor and Heatsink Installation ......................................................5-2
5-3 Connecting Cables ............................................................................................5-6
Connecting Data Cables ............................................................................5-6
Connecting Power Cables ..........................................................................5-6
Connecting the Control Panel ...................................................................5-7
5-4 Installing Memory in the MEC .........................................................................5-8
5-5 Adding PCI Cards............................................................................................5-11
5-6 I/O Ports ...........................................................................................................5-11
5-7 Serverboard Details .........................................................................................5-12
Serverboard Layout ...................................................................................5-12
P4QH8/P4QH6 Quick Reference.............................................................5-13
5-8 Connector Definitions ......................................................................................5-14
Main ATX Power Connection ................................................................. 5-14
Secondary Power Connections................................................................5-14
Power LED.................................................................................................5-14
IDE/HDD LED .......................................................................................... 5-14
PWR_ON....................................................................................................5-15
Reset..........................................................................................................5-15
NIC_LED ....................................................................................................5-15
I
2
C ...............................................................................................................5-16
Chassis Intrusion .................................................................................... 5-16
Keyboard Lock ........................................................................................ 5-16
Overheat LED (OH) ................................................................................. 5-16
Speaker.................................................................................................... 5-16
Fan Headers ..............................................................................................5-17
Serial Ports ...............................................................................................5-17
ATX PS/2 Keyboard and Mouse Ports ...................................................5-17
Universal Serial Bus (USB).................................................................... 5-17
IPMB......................................................................................................... 5-17
SMB ...........................................................................................................5-18
Wake-On-LAN............................................................................................5-18
vii
Table of Contents
viii
Wake-On-Ring ...........................................................................................5-18
Power Supply Fail Header .......................................................................5-18
NMI Header.............................................................................................. 5-19
5-9 DIP Switch Settings ........................................................................................5-19
DIP Switch 1: Processor Speed .............................................................5-19
5-10 Jumper Settings...............................................................................................5-20
Explanation of Jumpers............................................................................5-20
CMOS Clear ..............................................................................................5-20
SCSI Termination Enable/Disable ...........................................................5-20
LAN Enable/Disable................................................................................ 5-21
Spread Spectrum Enable/Disable ......................................................... 5-21
Third Power Supply Fail Alarm Enable/Disable.....................................5-21
LVD Channel A SCSI Termination Enable/Disable ...............................5-22
LVD Channel B SCSI Termination Enable/Disable ...............................5-22
Overheat Fan Force On............................................................................5-22
VGA Enable/Disable .................................................................................5-22
5-11 Debug LEDs .....................................................................................................5-23
5-12 Parallel Port, Floppy/Hard Disk Drive and SCSI Connections ...................5-24
Parallel Port Connector .......................................................................... 5-24
Floppy Connector .................................................................................... 5-25
IDE Connectors ....................................................................................... 5-25
SCSI Connectors ......................................................................................5-26
5-13 Installing Software Drivers ..............................................................................5-27
Chapter 6: Advanced Chassis Setup
6-1 Static-Sensitive Devices ................................................................................ 6-1
6-2 Control Panel .....................................................................................................6-2
6-3 System Fans......................................................................................................6-4
System Fan Failure ....................................................................................6-4
Replacing System Cooling Fans...............................................................6-5
Replacing System Exhaust Fans .............................................................6-6
6-4 Drive Bay Installation/Removal .........................................................................6-6
SCSI Drive Installation.............................................................................. 6-7
CD-ROM and Floppy Drive Installation ................................................. 6-10
6-5 Power Supply Modules ...................................................................................6-11
Power Supply Failure ...............................................................................6-11
Replacing Power Modules........................................................................6-11
SUPERSERVER 8042-8/8042-6 Manual
Table of Contents
ix
Chapter 7: BIOS
7-1 Introduction....................................................................................................... 7-1
7-2 BIOS Features ...................................................................................................7-2
7-3 Running Setup ...................................................................................................7-2
7-4 Advanced BIOS Setup ......................................................................................7-4
7-5 Chipset Setup ..................................................................................................7-14
7-6 PCI PnP Setup ................................................................................................7-16
7-7 Power Setup.....................................................................................................7-18
7-8 Boot Setup .......................................................................................................7-20
7-9 Security Setup .................................................................................................7-22
7-10 Exit....................................................................................................................7-24
Appendices:
Appendix A: BIOS Error Beep Codes .................................................................. A-1
Appendix B: BIOS POST Checkpoint Codes.........................................................B-1
Appendix C: System Specifications ......................................................................C-1
Notes
x
SUPERSERVER 8042-8/8042-6 Manual
Chapter 1
Introduction
1-1 Overview
The Supermicro SuperServer 8042-8/8042-6 is a high-end quad processor
in a 4U rackmount configuration. The SuperServer 8042-8/8042-6 is com-
prised of two main subsystems: the SC862 high-end server chassis and
the P4QH8/P4QH6 quad Xeon processor serverboard. Please refer to our
web site for information on operating systems that have been certified for
use with the SuperServer 8042-8/8042-6.
In addition to the serverboard and chassis, various hardware components
have been included with the SuperServer 8042-8/8042-6, as listed below:
! Up to four (4) 603-pin Intel Xeon processors MP (optional)
! Four (4) CPU heatsinks (FAN-042-CF)
! Up to 32 GB ECC registered DDR200 (PC1600) SDRAM (optional)
! One (1) MEC (Memory Expansion Card)
! One (1) 3.5" floppy drive
! One (1) slim CD-ROM drive
! SCSI Accessories
One (1) 68-pin Ultra320/160 SCSI cable (for SCA SCSI backplane)
Four (4) SCA 1-inch high SCSI drive carriers
One (1) SCA SCSI backplane
One (1) SCSI manual
! Rackmount hardware (with screws):
Two (2) rack rail assemblies
Six (6) brackets for mounting the rack rails to a rack/telco rack
! One (1) CD containing drivers and utilities
! SuperServer 8042-8/8042-6 User's Manual
Chapter 1: Introduction
1-1
1-2
SUPERSERVER 8042-8/8042-6 Manual
1-2 Serverboard Features
At the heart of the SuperServer 8042-8/8042-6 lies the P4QH8/P4QH6, a quad
processor serverboard based on ServerWorks GC-HE chipset and designed to
provide maximum performance with the newest technology available. Below are
the main features of the P4QH8/P4QH6. (See Figure 1-1 for a block diagram of
the GC-HE chipset).
Processors
The P4QH8/P4QH6 supports up to four Intel Xeon processors MP of up to 2.86
GHz with a 400 MHz FSB. Please refer to the support section of our web site
for a complete listing of supported processors (http://www.supermicro.com/
TechSupport.htm).
Memory
The P4QH8/P4QH6 has an MEC card that plugs into a special slot on the
serverboard. This MEC card has 16 184-pin DIMM slots that can support up
to 32 GB of registered ECC DDR200 (PC1600) SDRAM. Module sizes of
128MB, 256MB, 512MB 1GB and 2GB may be used to populate the DIMM
slots. (DDR266 is also supported, but only at 200 MHz.)
Onboard SCSI
8042-8: Onboard SCSI is provided with an Adaptec AIC-7902 SCSI chip,
which supports dual channel, Ultra320 SCSI at a throughput of 320 MB/sec
for each channel. The P4QH8 provides two Ultra320 SCSI ports.
8042-6: Onboard SCSI is provided with an Adaptec AIC-7899 SCSI chip,
which supports dual channel, Ultra160 SCSI at a throughput of 160 MB/sec
for each channel. The P4QH6 provides two Ultra160 SCSI ports.
PCI Expansion Slots
The P4QH8/P4QH6 has a total of six 64-bit 100 MHz PCI-X slots.
Onboard Controllers/Ports
Onboard are one floppy drive controller and two ATA/100 controllers, which
support up to four hard drives or ATAPI devices. The color-coded I/O ports
include a VGA port, one COM port, a parallel port, two USB ports, PS/2
1-3
Chapter 1: Introduction
mouse and keyboard ports and one 10/100 Mb LAN (Ethernet) port.
Other Features
Other onboard features that promote system health include onboard voltage
monitors, a chassis intrusion header, auto-switching voltage regulators,
chassis and CPU overheat sensors, virus protection and BIOS rescue.
Figure 1-1. ServerWorks GC-HE Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
CMIC
400 MHz Host Bus
CPU 2 CPU 1CPU 4 CPU 3
CIOB30
REMC
288-bit,
200 MHz
Memory
Bus
REMC
REMC
REMC
Memory Board (32 GB Total)
CIOB30
DIMM Slots
ZCR
PCI-X Slot
SCSI
Controller
PCI-X Slot
PCI-X Slot
PCI-X Slot
PCI-X Slot
PCI-X Slot
CSB5
IPMI
SIO USB 1.1
ATA-100
IDE
BIOS
Serial
Port
Parallel
Port
Floppy
LAN VGA
Thin IMB
IMB Bus
1-4
SUPERSERVER 8042-8/8042-6 Manual
1-3 Server Chassis Features
The SuperServer 8042-8/8042-6 is a high-end, scaleable server platform
designed with today's most state-of-the-art features. The following is a
general outline of the main features of the SC862 server chassis.
System Power
The 8042-8/8042-6 features a triple redundant power supply consisting of
three hot-swappable 350 watt power modules, which supply 700 watts of
continuous power with a 350 watt backup. If any of the three modules fail,
you will be notified by an alarm and an LED and the remaining two modules
will take up the load. The alarm reset button located on the control panel
can be depressed to deactivate the power fail alarm.
SCSI Subsystem
The SCSI subsystem supports up to four 80-pin SCA Ultra320 (8042-8) or
Ultra160 SCSI (8042-6) hard drives. (Any standard 1" drives are sup-
ported. SCA = Single Connection Attachment.) The SCSI drives are con-
nected to an SCA backplane. The SCSI drives are hot-swap units. A RAID
controller card can be used with the SCA backplane to provide data secu-
rity.
Note: The operating system you use must have RAID support to enable the
hot-swap capability of the SCSI drives.
Front Control Panel
The control panel on the SuperServer 8042-8/8042-6 provides you with
system monitoring and control. LEDs indicate network activity, power sup-
ply failure, fan failure, SCSI drive activity and failure and SCA backplane
overheat conditions. A main power button, a system reset button and an
alarm reset switch are also included.
I/O Backplane
The SC862 is a 4U rackmount, WTX form factor chassis. The I/O backplane
provides seven expansion slots, one COM port, one VGA port, a parallel
port, two USB ports, PS/2 mouse and keyboard ports and an Ethernet port.
1-5
Chapter 1: Introduction
Cooling System
The SC862 chassis has an innovative cooling design that includes four 9-
cm hot-plug redundant system cooling (intake) fans and two 9-cm exhaust
fans. All system fans (located between the drive bays and the
serverboard) operate continuously. If one fails, an alarm is activated and
the RPM of the remaining fans increase to compensate and maintain suffi-
cient airflow.
1-6
SUPERSERVER 8042-8/8042-6 Manual
1-4 Contacting Supermicro
Headquarters
Address: SuperMicro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: [email protected] (General Information)
[email protected] (Technical Support)
Web Site: www.supermicro.com
Europe
Address: SuperMicro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: [email protected] (General Information)
[email protected] (Technical Support)
[email protected] (Customer Support)
Asia-Pacific
Address: SuperMicro, Taiwan
D5, 4F, No. 16 Chien-Ba Road
Chung-Ho 235, Taipei Hsien, Taiwan, R.O.C.
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Tel: 886-2-8228-1366, ext.132 or 139
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 8042-
8/8042-6 up and running. Following these steps in the order given should
enable you to have the system operational within a minimum amount of time.
This quick setup assumes that your SuperServer 8042-8/8042-6 system
has come to you with the processors and memory preinstalled. If your
system is not already fully integrated with a serverboard, processors, sys-
tem memory etc., please turn to the chapter or section noted in each step
for details on installing the specific component.
2-2 Unpacking the SuperServer 8042-8/8042-6
You should inspect the box the SuperServer 8042-8/8042-6 was shipped in
and note if it was damaged in any way. If the server itself shows damage
you should file a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer
8042-8/8042-6. It should be situated in a clean, dust-free area that is well
ventilated. Avoid areas where heat, electrical noise and electromagnetic
fields are generated. You will also need it placed near a grounded power
outlet. Read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 8042-8/8042-6 was shipped in should include two
sets of rail assemblies, two rail mounting brackets and the mounting screws
you will need to install the system into the rack. Follow the steps in the
order given to complete the installation process in a minimum amount of time.
Please read this section in its entirety before you begin the installation
procedure outlined in the sections that follow.
2-2
SUPERSERVER 8042-8/8042-6 Manual
Choosing a Setup Location:
- Leave enough clearance in front of the rack to enable you to open
the front door completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the rack
to allow for sufficient airflow and ease in servicing.
Rack Precautions:
- Ensure that the leveling jacks on the bottom of the rack are fully
extended to the floor with the full weight of the rack resting on them.
- In single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component
from the rack.
- You should extend only one component at a time - extending two or
more simultaneously may cause the rack to become unstable.
Server Precautions:
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you
install the rails.
- Install the heaviest server components on the bottom of the rack
first, and then work up.
- Use a regulating uninterruptible power supply (UPS) to protect the
server from power surges and voltage spikes and to keep your
system operating in case of a power failure.
- Allow the hot plug SCSI drives and power supply units to cool before
touching them.
- Always keep the rack's front door and all panels and components on
the servers closed when not servicing to maintain proper cooling.
!
!
Warnings and Precautions!
Chapter 2: Server Installation
2-3
2-4 Installing the 8042-8/8042-6 into a Rack
This section provides information on installing the SuperServer 8042-8/
8042-6 into a rack unit. If the 8042-8/8042-6 has already been mounted into
a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of
rack units on the market, which may mean the assembly procedure will
differ slightly. The following is a guideline for installing the 8042-8/8042-6
into a rack with the rack rails provided. You should also refer to the
installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails:
You should have received two rack rail assemblies with the SuperServer
8042-8/8042-6. Each of these assemblies consist of three sections: an
inner fixed chassis rail that secures to the 8042-8/8042-6 (A), an outer
fixed rack rail that secures directly to the rack itself (B), and a sliding rail
guide (C) between the two, which should remain attached to the fixed
rack rail. (See Figure 2-1, which shows the chassis rail 'A' already
attached to the chassis).
The first thing you must do is to remove the fixed chassis rail (A) from
each assembly. To do this, pull this inner rail out as far as possible
- you should hear a "click" sound as a locking tab emerges from inside
the rail assembly and locks the inner rail. Depress the locking tab to pull
the inner rail completely out.
Figure 2-1. Identifying the Sections of the Rack Rails
A
C
B
2-4
SUPERSERVER 8042-8/8042-6 Manual
Installing the Chassis Rails:
Position the fixed chassis rail sections you just removed along the side of
the 8042-8/8042-6 chassis making sure the five screw holes line up. Be
aware that these two rails are left/right specific. Screw the rail securely
to the side of the chassis (see Figure 2-2). Repeat this procedure for
the other rail on the other side of the chassis.
Locking Tabs: As you have seen, both chassis rails have a locking tab,
which serves two functions. The first is to lock the server into place
when installed and pushed fully into the rack, which is its normal position.
These tabs also lock the server in place when fully extended from the
rack. This prevents the server from coming completely out of the rack
when you pull it out for servicing.
Figure 2-2. Installing the Chassis Rails
Installing the Rack Rails:
Determine where you want to place the 8042-8/8042-6 in the rack.
(See Rack and Server Precautions in Section 2-3.) Position the fixed rack
rail/sliding rail guide assemblies at the desired location in the rack,
keeping the sliding rail guide facing the inside of the rack. Screw the
assembly securely to the rack using the brackets provided. Attach the
other assembly to the other side of the rack, making both are at the exact
same height and with the rail guides facing inward (see Figure 2-3).
Locking Tab
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114

Supermicro 8042-8 User manual

Category
Server barebones
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI