19) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole and two raised dimples, wrap ground wire from outlet
box around green ground screw, and thread into hole.
b) On xtures where a cupped washer is provided,aach ground wire from outlet box under cupped washer and
green ground screw, then thread into mounng strap.
If xture is provided with ground wire, connect xture ground wire to outlet box ground wire with wire connector
aer following the above steps. Never connect ground wire to black or white power supply wires.
20) Make wire connecon. Reference chart below for correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth
(see illus.)
Neutral Wire
21) Aach the safety cable[D] to the mounng strap or to the inside of the outlet box.
22) Push xture to ceiling, carefully passing mounng screws through holes in canopy[H].
NOTE: Be certain wires do not get pinched between mounng strap and canopy, or canopy and ceiling.
23) Use knobs[K] and lockwashers[N] to secure canopy. Tighten to secure.
24) Aach upper trim piece[S] to upper bar[U] by aligning holes on ends of bar with holes on top of upper trim piece.
Insert studded nials[V] into aligned holes and screw nial[W] onto threads protruding from inside trim piece (2
places).
25) Aach small glass panel[Y] to upper trim piece[S] by aligning two (2) holes on glass with holes on side of upper
trim piece. Insert studded nial[X] into aligned holes. Slip nylon washer[AA] onto protruding threads on inside
of upper trim piece and screw nial[Z] onto threads. Repeat to aach other small glass panel to opposite side of
upper trim piece. Do not ghten nials completely.
26) Aach small glass panel to lower trim piece[AB] by aligning holes in glass panel with holes on side of lower trim
piece. Insert studded nial[X] into aligned holes. Slip nylon washer[AA] onto protruding threads on inside of lower
trim piece and screw nial[Z] onto threads. Repeat to aach other small glass panel to opposite side of lower trim
piece. Do not ghten nials completely.
27) Aach large glass panels[O] to upper trim piece[S] by aligning two (2) holes on glass with holes on side of upper
trim piece. Insert studded nial[X] into aligned holes. Slip nylon washer[AA] onto protruding threads on inside of
upper trim piece and screw nial[Z] onto threads. Repeat to aach other large glass panel to opposite side of upper
trim piece. Do not ghten nials completely.
28) Aach large glass panel to lower trim piece[AB] by aligning holes in glass panel with holes on side of lower trim
piece. Insert studded nial[X] into aligned holes. Slip nylon washer[AA] onto protruding threads on inside of lower
trim piece and screw nial[Z] onto threads. Repeat to aach other small glass panel to opposite side of lower trim
piece.
29) Tighten all (16) nials to secure glass panels to upper and lower trim pieces.
30) Insert recommended bulbs. (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements, installaon by a cered electrician is recommended.
CLEANING:
• Always be certain that electric current is turned o before cleaning.
• Only a so damp cloth should be used. Harsh cleaning products may damage the nish.
Installaon Instrucons
[A] Stems
[B] Short Threaded Tubes
[C] Outlet Box
[D] Safety Cable
[E] Lockwasher
[F] Hexnut
[G] Mounting Strap
[H] Canopy
[I] Strap Mounting Screws
[J] Mounting Screws
[K] Knobs
[L] Second Loop
[M] Chain Link
[N] Lockwashers
[O] Large Glass Panel
[P] Ground Wire Loop
[Q] First Loop
[R] Long Threaded Tube
[S] Upper Trim Piece
[T] Center Tube
[U] Upper Bar
[V] Studded Finials
[W] Finial
[X] Studded Finial
[Y] Small Glass Panel
[Z] Finial
[AA] Nylon Washer
[AB] Lower Trim Piece
[AC] Socket Bar
RIGID STEM MOUNT
1) On side of xture with xture wires, pass xture wires through a short threaded tube[B] and center tube[T]. Screw
center tube into coupling aached to socket bar[AC] using short threaded tube[B].
2) On opposite side of xture (without xture wires) Screw a center tube into coupling aached to socket bar using a
short threaded tube.
3) On side of xture with xture wires, pass xture wire from center tube[T] through long threaded tube[R] and
screw long threaded tube into center tube.
4) On opposite side of xture (without xture wires) Screw remaining long threaded tube into other center tube.
5) On side of xture with xture wires, pass xture wires through one of the center holes in upper bar[U] and through
desired number of stems[A] and short threaded tubes[B]. Screw stems together using short threaded tubes.
6) On opposite side of xture (without xture wires) screw a second set of stems and tubes together using short
threaded tubes (same number of stems and tubes from previous step but without xture wire).
NOTE: Thread locking compound must be applied to all stem threads as noted with symbol (4) to prevent
accidental rotaon of xture during cleaning, relamping, etc.
7) Insert exposed ends of long threaded tubes[R] into center holes in upper bar[U].
8) On side of xture with xture wires, screw rst stem of connected set of stems onto exposed threads of long
threaded tube protruding through upper bar.
9) On opposite side of xture (without xture wires) screw rst stem of connected set of stems onto exposed threads
of long threaded tube protruding through upper bar.
10) On side of xture with xture wires, pass xture wires through one short threaded tube[B]. Screw short threaded
tube onto top of stem.
11) On opposite side of xture (without xture wires), screw one short threaded tube onto top of stem.
12) Pass xture wires through hole in canopy[H]. Lower canopy down towards stems. Pass holes in canopy over ends of
short threaded tubes on top of the stems.
13) On side of xture with xture wires, pass xture wires through loop of safety cable[D]. Slip loop of safety cable
over end of short threaded tube protruding from inside of canopy.
14) Pass xture wires through lockwasher[E]. Place lockwasher onto end of short threaded tube protruding from inside
canopy.
15) Pass xture wires through hexnut[F]. Thread hexnut onto end of short threaded tube.
NOTE: Fixture wires should not be cut shorter than 20 inches from above the canopy.
16) On opposite side of xture (without xture wires), place loop of ground wire[P] over short threaded tube
protruding from inside of canopy and secure into place with a lock washer and hexnut as shown.
17) Find the appropriate threaded holes on mounng strap[G]. Assemble mounng screws[J] into threaded holes (if
they are not already installed).
18) Aach mounng strap to outlet box[C] using the strap mounng screws[I]. Mounng strap can be adjusted to suit
posion of xture.
Installaon Instrucons (connued)
LOOP / CHAIN LINK MOUNT
1) Follow steps 1 - 9 from “Rigid Stem Mount” Instrucons.
2) Thread one short threaded tube[B] into end of each small loop[Q, L].
3) On side of xture with xture wires, pass xture wires through rst loop[Q]. Thread rst loop onto end of last stem.
4) Pass xture wires through second loop[L] and through hole in canopy[H]. Pass short threaded tube at end of second
loop through hole in canopy.
5) Pass xture wires through loop of safety cable[D]. Slip loop of safety cable over end of short threaded tube protruding
from inside of canopy.
6) Pass xture wires through lockwasher[E]. Place lockwasher onto end of short threaded tube protruding from inside
canopy.
7) Pass xture wires through hexnut[F]. Thread hexnut onto end of short threaded tube.
NOTE: Fixture wires should not be cut shorter than 20 inches from above the canopy.
8) On opposite side of xture (without xture wires), Thread rst loop[Q] onto end of last stem. Pass threaded pipe at end
of second loop[L] through hole in canopy.
9) Place loop of ground wire[P] over short threaded tube protruding from inside of canopy and secure into place with a
lock washer and hexnut as shown.
10) Aach open chain link[M] to small loops at end of each stem and to small loops on canopy and close the open chain link
by placing a piece of cloth over the open link and using a pair of pliers gently squeeze the link closed.
11) Follow steps 17 - 30 from “Rigid Stem Mount” Instrucons.
P
D
F
E
J
I
C
G
F
E
►
►
►
►
A
B
►
►
K
N
H
R
U
T
S
B
V
X
Y
W
Z
AA
X
Z
AA
AB
AC
B
Q
M
L
A
B
P
D
F
E
J
I
C
G
F
E
►
►
►
►
A
B
►
►
K
N
H
R
U
T
S
B
V
X
Y
W
Z
AA
X
Z
AA
AB
AC
O
Z
AA
Z
AA
S
AB
X
X
FRONT VIEW
SIDE VIEW