4000TOCe Sensor 6
© 08/ 17 METTLER TOLEDO Thornton 4000TOCe Sensor
Printed in USA
8 Quick Setup _____________________________________________________________________________________________ 33
9 Sensor Calibration _______________________________________________________________________________________ 34
9.1 Enter Calibration Mode ________________________________________________________________________________ 34
10 Conguration ____________________________________________________________________________________________ 35
10.1 EnterCongurationMode ______________________________________________________________________________ 35
10.2 Measurement _______________________________________________________________________________________ 35
10.2.1 Channel Setup ________________________________________________________________________________ 35
10.2.2 Conductivity/Resistivity Temperature Compensation ___________________________________________________ 36
10.2.3 Set Averaging ________________________________________________________________________________ 36
10.3 TOC Setup __________________________________________________________________________________________ 36
10.3.1 TOC General Parameters ________________________________________________________________________ 36
10.3.2 Lamp Control _________________________________________________________________________________ 37
10.3.3 Autobalance _________________________________________________________________________________ 37
10.4 Analog Outputs ______________________________________________________________________________________ 38
10.5 Setpoints __________________________________________________________________________________________ 39
10.6 Alarm _____________________________________________________________________________________________ 42
10.7 Display ____________________________________________________________________________________________ 43
10.7.1 Measurement _________________________________________________________________________________ 43
10.7.2 Resolution ___________________________________________________________________________________ 43
10.7.3 Backlight ____________________________________________________________________________________ 43
10.7.4 Name ______________________________________________________________________________________ 44
10.8 Hold Analog Outputs _________________________________________________________________________________ 44
11 System _________________________________________________________________________________________________ 45
11.1 Set Language _______________________________________________________________________________________ 45
11.2 Passwords _________________________________________________________________________________________ 45
11.2.1 Changing Passwords __________________________________________________________________________ 46
11.2.2 ConguringMenuAccessforOperator _____________________________________________________________ 46
11.3 Set/Clear Lockout ____________________________________________________________________________________ 46
11.4 Reset _____________________________________________________________________________________________ 46
11.4.1 Reset System _________________________________________________________________________________ 47
11.4.2 Reset Analog Calibration ________________________________________________________________________ 47
11.4.3 Reset Sensor Calibration Data to Factory Settings _____________________________________________________ 47
11.4.4 Reset Calibration Data of Sensor Electronics to Factory Settings __________________________________________ 47
12 4000TOCe Sensor Service Requirements _____________________________________________________________________ 48
12.1 UV Lamp Replacement ________________________________________________________________________________ 48
12.2 High Capacity Inlet Filter Replacement ____________________________________________________________________ 49
12.3 Front Panel Cleaning _________________________________________________________________________________ 49
12.4 Technical Support ____________________________________________________________________________________ 50
12.5 Draining and Shipping Instructions ______________________________________________________________________ 50
13 M300 TOC Service _______________________________________________________________________________________ 51
13.1 Enter Service Menu ___________________________________________________________________________________ 51
13.2 Diagnostics ________________________________________________________________________________________ 51
13.2.1 Model/Software Revision ________________________________________________________________________ 51
13.2.2 Display _____________________________________________________________________________________ 51
13.2.3 Keypad _____________________________________________________________________________________ 52
13.2.4 Memory _____________________________________________________________________________________ 52
13.2.5 Set Relay ____________________________________________________________________________________ 52
13.2.6 Read Relays _________________________________________________________________________________ 52
13.2.7 Set Analog Outputs ____________________________________________________________________________ 53
13.2.8 Read Analog Outputs ___________________________________________________________________________ 53
13.3 Calibrate ___________________________________________________________________________________________ 53
13.3.1 Verify Conductivity Electronics ____________________________________________________________________ 53
13.3.2 Calibrate Analog ______________________________________________________________________________ 53
13.3.3 Calibrate Unlock ______________________________________________________________________________ 54
13.4 Tech Service ________________________________________________________________________________________ 54
14 Info ____________________________________________________________________________________________________ 55
14.1 Info Menu __________________________________________________________________________________________ 55
14.2 Messages __________________________________________________________________________________________ 55
14.3 Calibration Data _____________________________________________________________________________________ 55
14.4 Model/Software Revision ______________________________________________________________________________ 56
14.5 TOC Sensor Info _____________________________________________________________________________________ 56
15 Troubleshooting the M300 TOC Transmitter ___________________________________________________________________ 57
15.1 Changing the Fuse ___________________________________________________________________________________ 57
15.2 Warning- and Alarm indication on the display _____________________________________________________________ 58
15.2.1 Warning indication ____________________________________________________________________________ 58
15.2.2 Alarm indication ______________________________________________________________________________ 58