Mettler Toledo 4E Sanitary Conductivity/Resistivity Sensors Thornton Instruments Operating instructions

Type
Operating instructions

Mettler Toledo 4E Sanitary Conductivity/Resistivity Sensors Thornton Instruments are designed to provide accurate and reliable measurements of conductivity and resistivity in a wide range of applications. These sensors are ideal for use in the food and beverage, pharmaceutical, and chemical industries.

The 4E sensors are constructed of high-quality materials that are resistant to corrosion and chemicals. They are also designed to withstand high temperatures and pressures. The sensors are easy to install and maintain, and they can be used in a variety of mounting positions.

The 4E sensors are available with a variety of options, including different electrode materials, cell constants, and temperature ranges. This allows users to select the sensor that is best suited for their specific application.

Mettler Toledo 4E Sanitary Conductivity/Resistivity Sensors Thornton Instruments are designed to provide accurate and reliable measurements of conductivity and resistivity in a wide range of applications. These sensors are ideal for use in the food and beverage, pharmaceutical, and chemical industries.

The 4E sensors are constructed of high-quality materials that are resistant to corrosion and chemicals. They are also designed to withstand high temperatures and pressures. The sensors are easy to install and maintain, and they can be used in a variety of mounting positions.

The 4E sensors are available with a variety of options, including different electrode materials, cell constants, and temperature ranges. This allows users to select the sensor that is best suited for their specific application.

THORNTON
Leading Pure Water Analytics
INSTALLATION INSTRUCTIONS
4E SANITARY CONDUCTIVITY / RESISTIVITY SENSORS
TYPICAL NOT
INSTALLATIONS
READ THIS FIRST
RECOMMENDED
RECOMMENDED
MOUNTING
OUTLET
INLET
84290F1
This is the ideal mountin
g
p
ositio
n
This is the ideal
mounting position
The solution flow should be directed
into the end of the sensor and
allowed to pass out of the
circulation holes of the outer
electrode.
The sensor should be mounted so
the cavity does not trap air or solids.
OUTLET
INLET
OUTLET
84290F3
AIR
SOLIDS
INLET OUTLET
84290F2
Vertical mounting is possible, if the
pipe is full and bubbles do not
accumulate near the electrodes.
Horizontal branch mounting is
usually a better alternative. The
solution must circulate past the
electrodes for accurate
measurements.
INLET OUTLET
84290F2
OUTLET
INLET
84290F4
Mount the sensor in a vertical pipe
with the flow direction up. Mettler-
Toledo Thornton, Inc. does not
recommend mounting the sensor in
a vertical pipe with the flow
direction down, because air bubbles
or air pockets will affect the sensor
measurement.
OUTLET
INLET
84290F5
Sensor Maintenance
Note: Contaminated sensors can give inaccurate high or low readings, depending upon the type
and location of contaminant accumulation. Both the electrodes and the insulating surfaces
must be cleaned to ensure accurate readings.
If contamination is suspected, removed the sensor from its fitting and clean the electrodes and
insulator. When cleaning, use a cotton swab saturated with a mild detergent or a very diluted
(0.5% or less) inorganic acid, i.e. HCl (Hydrochloric Acid), H
2
SO
4
(Sulfuric Acid), HNO
3
(Nitric Acid). If cleaning with acid use standard acid handling safety procedures.
Rinse thoroughly with distilled or deoinized water before installation. Avoid touching the
cleaned surfaces because oil from your hands will recontaminate the sensorl.
DO NOT USE ABRASIVE MATERIALS such as steel wool or nylon scrubbers, these
may harm the electrode surface and could affect the accuracy.
Mettler-Toledo Thornton, Inc. Toll-Free: 800-510-PURE
36 Middlesex Turnpike Fax: 781-271-0214
Bedford, MA 01730 info@thorntoninc.com
(781) 301-8600
www.thorntoninc.com
OM84377 Rev. B 01/04
  • Page 1 1
  • Page 2 2

Mettler Toledo 4E Sanitary Conductivity/Resistivity Sensors Thornton Instruments Operating instructions

Type
Operating instructions

Mettler Toledo 4E Sanitary Conductivity/Resistivity Sensors Thornton Instruments are designed to provide accurate and reliable measurements of conductivity and resistivity in a wide range of applications. These sensors are ideal for use in the food and beverage, pharmaceutical, and chemical industries.

The 4E sensors are constructed of high-quality materials that are resistant to corrosion and chemicals. They are also designed to withstand high temperatures and pressures. The sensors are easy to install and maintain, and they can be used in a variety of mounting positions.

The 4E sensors are available with a variety of options, including different electrode materials, cell constants, and temperature ranges. This allows users to select the sensor that is best suited for their specific application.