  • Hello! I am an AI chatbot trained to assist you with the DAVIS Multi-purpose Shelter Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
(
510
)
732-9229
t
www.davisnet.com
3465 Diablo Ave., Hayward, CA 94545-2778 USA
®
Multi-Purpose
Shelter
For Davis Equipment Installed Outdoors
Product Number 7728
Components
1
MULTI-PURPOSE SHELTER
TheweatherresistantMultiPurposeShelter(MPS)maybeusedtoprotecta
numberofsystemcomponentsfromtheelements.
CAUTION: We have made every attempt to design and manufacture a safe product,
however Davis Instruments assumes no liability for any injury or damage
caused directly or indirectly by the installation or use of this product.
COMPONENTS
TheMultiPurposeShelter(MPS)includesthefollowingcomponents.Please
makesurethatyouhaveallthelistedcomponentsbeforecontinuing.
COMPONENTS
Multi-Purpose Shelter
2
ThehardwarekitincludedwiththeMPSincludesthefollowingcomponents.
Pleasemakesurethatyouhaveallthecomponentsbeforecontinuing.
HARDWARE KIT COMPONENTS
Thegroundlugkitincludedwiththeshelterincludesthefollowingcompo
nents.Pl
easemakesurethatyouhaveallthecomponentsbeforecontinuing.
GROUND LUG KIT COMPONENTS
TOOLS AND MATERIALS NEEDED FOR INSTALLATION
Youmayneedsomeofthefollowingtoolsandmaterialsinordertoinstallthe
shelter.
System Components
Youwillneedtheva
rioussystemcomponentsyouplantoinstallinside
theshelter.Somesampleinstallationconfigurationsareshownin“Sam
pleMPSConfigurations”onpage3.
Medium Flat Head Screwdriver
Medium Phillips Head Screwdriver
Wrench or 3/8" Nut Driver
Large Adjustable Wrench (1 3/8" Opening)
Wire Cutter
Wire Stripper or Knife
Pliers
Electrical Tape and/or Silicone Caulking
Double-Sided Tape
Attaching Cable Strain Reliefs
3
ATTACHING CABLE STRAIN RELIEFS
AttachbothstrainreliefstotheMPSasshownbelow.Youwillneedtoinstall
thestrainreliefsbeforerunningcablesintotheMPS.Securethestrainreliefsby
tighteningthelocknuts.Donottightenthecompressionnutsuntilyouhave
completedyourinstallation(see“Se
curingtheCables”onpage9).
INSTALLING STRAIN RELIEFS
SAMPLE MPS CONFIGURATIONS
TheillustrationsbelowshowsampleMPSinstallations.Consulttheinstallation
manualssuppliedwithsystemcomponentsforwiringinstructions.
Weather Envoy
Theil
lustrationbelowshowsanMPSinstallationforawirelessWeatherEnvoy.
Weather ENVOY
WEATHER ENVOY INSTALLATION
Multi-Purpose Shelter
4
Console and Small Junction Box
Theil
lustrationbelowshowsanMPSinstallationwhichincludesaconsoleand
smalljunctionbox.
F
OUTSIDE
TEMPERATURE
MPH
N
NE
SW
NW
SE
EW
S
RAIN
TEMP
WIND
WEATHER
COMPUTER
CONSOLE,AND SMALL JUNCTION BOX
INSTALLING COMPONENTS INTO THE MPS
Thesectionsbelowshowwhereandhowthevarioussystemcomponents
installintotheMPS.Youwillneedtoconsulttheinstallationmanualssupplied
witheachsystemcomponentforinstructionsonwiringyourinstallation.You
maywanttowaituntilyouhaveactuallymountedtheshelter(See“M
ounting
theMPS”onpage6)beforeroutingcablesintotheshelter.
Installing a Weather Envoy
Us
ethe#6x1/2ʺ(12.5mm)selftappingscrewsasshownbelow.
Weather ENVOY
INSTALLING A WEATHER ENVOY
Installing Components into the MPS
5
Installing a Console
Youmayinstallth
estationconsoleintotheboxorthecover,usingthescrews
shownbelow.
INSTALLING A CONSOLE
Installing a Small Junction Box
Youmayinstallthesmalljunctionboxintotheboxorthecover,usingthe
screwsshownbelow.
INSTALLING A SMALL JUNCTION BOX
Multi-Purpose Shelter
6
MOUNTING THE MPS
Theinstructionsbelowwillshowyouhowtomounttheshelteragainstawall
orpost,onasmallpipe,oronalargepipe.
Mounting the Shelter on a Wall or Post
Attachth
esheltertothemountingsurfaceinthedesiredlocationusingthelag
screwsand1/4ʺflatwashersasshownbelow
Weather ENVOY
.
MOUNTING ON A WALL OR POST
Mounting On a Pipe
Holdtherearofth
eshelterandtheUboltsaddlesagainstthepipeandslide
theendsoftheUboltsthroughtheholesinthesaddlesandsheltersothatthe
Uboltswraparoundthepipeasshownbelow.Securetheshelterusingaflat
washerandhexnu
toneachendoftheUbolts.Tightenthehexnutsuntilthe
shelterisfirmlyattachedtothepipe.
If mounting on a pipe with outside diameter between 3/4" and 1-1/4"
(19 mm and 31 mm) use the 1-1/2" U-Bolts and saddles, and the 1/4"
washers and hex nuts.
Weather ENVOY
MOUNTING ON A SMALL PIPE
Grounding the Shelter and Components
7
If mounting on a pipe with outside diameter between 1-1/2" and 2 3/
8" (38 mm and 60 mm) use the 2-1/4" U-Bolts and saddles, and the
5/16" washers and hex nuts.
Weather ENVOY
MOUNTING ON A LARGE PIPE
GROUNDING THE SHELTER AND COMPONENTS
AttachthegroundlugtothebottomoftheMPSusinga#1032x1ʺ(25mm)
screw,washer,lockwasher,andhexnutasshownbelow.
INSTALLING GROUND LUG
Multi-Purpose Shelter
8
Runanygroundjumpersfromyoursystemcomponents tothegroundlugand
attachusingtheother#10washer,lockwasher,andhexnutasshownbelow.
ATTACHING GROUND JUMPERS TO GROUND LUG
GroundtheMPSusingtheprovidedgroundwire.Ifyouanticipateheavy
surges,youmaywishtouseaheavierwireormultiplewires.Cuttheground
wiretothelengthrequiredtoreachfromtheMPStoasuitableground..The
groundwireshouldbeasshortaspossible.Stripbothen
dsofthegroundwire
(removethespadelugifnecessary)andinsertoneendintothegroundlug.
Secureinplacebytighteningthegroundlugscrew.Attachtheotherendtoa
suitableground.
GROUNDING THE MPS
Securing the Cables
9
SECURING THE CABLES
Afterattachingallcables,tightenthecompressionnutsonthestrainreliefsto
securethecablesandcreateaweatherresistantseal.Ifthereisalargeairspace
aroundthecables,fillthespacebywrappingcablesinelectricaltapeand/or
sealingwithsiliconecaulking.
Compression Nut
RAIN
TEMP
WIND
WEATHER
COMPUTER
F
OUTSIDE
TEMPERATURE
MPH
N
NE
SW
NW
SE
EW
S
SECURING CABLES
Product Numbers: 7728
Davis Instruments Part Number: 7395.114
Multi-Purpose Shelter
Rev. C Manual 12/15/09
This product complies with the essential protection requirements of the EC EMC Directive
2004/108/EC.
© Davis Instruments Corp. 2009. All rights reserved.
VELCRO is a registered trademark of Velcro Industries, Manchester, NH.
3465 Diablo Avenue, Hayward, CA 94545-2778 U.S.A.
510-732-9229 • Fax: 510-732-9188
E-mail: [email protected] • www.davisnet.com
/