  • Hello! I am an AI chatbot trained to assist you with the Dometic eSYSTEM eCore 3kW Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
eCore 3kW
3kW Main Controller for eSystem
Operating manual . . . . . . . . . . . . . . . . . . . . 14
3kW Main Controller für eSystem
Bedienungsanleitung . . . . . . . . . . . . . . . . .76
3kW Main Controller pour eSystem
Notice d’utilisation . . . . . . . . . . . . . . . . . .140
3kW Main Controller para eSystem
Instrucciones de uso . . . . . . . . . . . . . . . . 206
Main Controller 3kW para o sistema
eSystem
Manual de instruções . . . . . . . . . . . . . . . 270
I3kW Main Controller per eSystem
Istruzioni per l’uso . . . . . . . . . . . . . . . . . . 336
EN
DE
FR
ES
PT
IT
CONTROL
eSYSTEM
eCore-3kW--O--WEST.book Seite 1 Donnerstag, 4. August 2016 2:22 14
eCore3kW
3
1 2 3 64 5
8 9 10
11
12
16
1514137
1
LINE ON
GENERATOR
STANDBY
SET
FAILURE
100%
75%
50%
25%
5%
CHARGER
INVERTER
Power
Sharing
AC
Load
Charge
Status
15 14 13 9 8 5 2
3
10
1
11
12
647
2
eCore-3kW--O--WEST.book Seite 3 Donnerstag, 4. August 2016 2:22 14
eCore3kW
5
Dometic
eCore
MANUAL MODE
GENERATOR
MODE
UPS MODE
SYSTEM
GENERATOR 0H
0.0KW 0RPM
ONLY CHARGER
15 s
INVERTER 30°C
230V 0.0A 0.0KW
AC IN - MAX20A
230V 0.0A 0.0KW
BATTERY 30°C
13.5V
> 1 s
AC OUT 00:00
230V 0.0A 0.0KW
System
Quick Setup
STANDBY
ACTIVE?
Standby
4
eCore-3kW--O--WEST.book Seite 5 Donnerstag, 4. August 2016 2:22 14
eCore3kW
6
GENERATOR 0H
0.0KW 0RPM
BATT SAVE-010:00
PAUSE?
INVERTER 30°C
230V 0.0A 0.0KW
AC IN - MAX20A
230V 0.0A 0.0KW
BATTERY 30°C
13.5V
Quick Setup
SYSTEM
System
AUTO MODE
Dometic
eCore
> 1 s
GEN AUTOSTART
ACTIVE?
15 s
15 s
> 1 s
STANDBY
ACTIVE?
Standby
AC OUT 00:00
230V 0.0A 0.0KW
5
eCore-3kW--O--WEST.book Seite 6 Donnerstag, 4. August 2016 2:22 14
eCore3kW
7
Quick Setup
DC BOOST
OFF?
> 1 s
MAX AC IN 6A
SETUP
MAX AC IN 6A
+ –
GEN AUTO
ACTIVE?
GENERATOR
ACTIVE?
MANUAL MODE
SETUP
WARNING BEEP
OFF?
MANUAL MODE
GENERATOR ON
MANUAL MODE
P. SHARING ON
MANUAL MODE
INVERTER ON
MANUAL MODE
LINE ON
MANUAL MODE
CHARGER ON
QUIET MODE
SETUP
START TIME 00:00
< > + –
QUIET MODE
SETUP
END TIME 00:00
< > + –
QUIET MODE
DISABLE?
> 1 s
YES NO
> 1 s
6
eCore-3kW--O--WEST.book Seite 7 Donnerstag, 4. August 2016 2:22 14
eCore3kW
9
System Setup
USER SETUP
DATE
DATE 00/00/00
< > + –
> 1 s
USER SETUP
SCREEN SAVE
SCREEN SAVE 1M
+ –
> 1 s
USER SETUP
RESET TO DEF.
CONFIRM RESET
> 1 s
USER SETUP
MAX AC
USER SETUP
QUIET SETUP
MAX AC IN 10.0A
+ –
> 1 s
USER SETUP
TIME
TIME 00:00
< > + –
> 1 s
START TIME 00:00
< > + –
QUIET MODE
SETUP
END TIME 00:00
< > + –
QUIET MODE
DISABLE?
> 1 s
YES
NO
> 1 s
8
eCore-3kW--O--WEST.book Seite 9 Donnerstag, 4. August 2016 2:22 14
eCore3kW
10
INFO
eCORE
INFO
ePOWER
INFO
eSTORE
INFO eSTORE
TOT CRG: 0000
INFO eSTORE
Connected: #1
INFO eSTORE #1
SN: 0000
IINFO eSTORE #1
HW: 0.00
INFO eSTORE
TOT DIS: 0000
INFO eSTORE #1
SW: 0.00
INFO eCORE
SN: 000000
INFO eCORE
HW P: 0.00
INFO eCORE
HW S: 0.00
INFO eCORE
FW S: 0.00
INFO eCORE
FW P: 0.00
INFO eCORE
WT_T: 0000H
INFO ePOWER
SN: 000000
INFO ePOWER
HW: 0.00
INFO ePOWER
SW: 0.00
INFO ePOWER
WT_T: 0000H
INFO ePOWER
WT_P: 0000H
System Info
9
System Alarm
ALARM LIST
eCore
ALARM eCore
C01R01 00H00M
ALARM LIST
eStore
ALARM eStore
C01R01 00H00M
ALARM LIST
ePower
ALARM ePower
C01R01 00H00M
ALARM eCore
C01R01 00H00M
ALARM eStore
C01R01 00H00M
ALARM ePower
C01R01 00H00M
0
eCore-3kW--O--WEST.book Seite 10 Donnerstag, 4. August 2016 2:22 14
eCore3kW
12
No action
eCORE running
in auto mode
*
NO
YES
YES
D+ on or
mains connected and
in tolerance?
eCore set
in auto mode?
NO
eCore in
standby?
eCore smart
wake-up off?
YES
NO
YES
NO
NO
Countdown stopped
by user?
eCore in smart
wake-up mode?
YES
NO
YES
NO
Countdown
finished?
Mains
connected or
DC Kit closed or
Generator on or
Output power
> 150 W?
Start/continue
countdown
Stop countdown
YES
NO
YES
eCORE running in
auto mode
eCORE running in
smart wake-up mode
eCore in standby
eCore in standby
Start
b
eCore-3kW--O--WEST.book Seite 12 Donnerstag, 4. August 2016 2:22 14
eCore3kW
13
*
Standby request
by user?
YES
YES
NO
AC
support off and
discharging
battery?
Smart wake-up
temporarily off
NO
Battery voltage >
min voltage ?
Gen Autostart
active ?
Mains connected?
NO
Countdown
finished?
Start/continue
countdown
Stop countdown
NO
YES
eCORE running in
smart wake-up mode
eCore in standby
NO
Countdown
finished?
Generator on or
DC Kit closed?
Start/continue
countdown
Stop countdown
Start generator
NO
YES NO
YES
NO YES
YES
eCORE in standby
eCORE running in
smart wake-up mode
Inverter stopped
c
eCore-3kW--O--WEST.book Seite 13 Donnerstag, 4. August 2016 2:22 14
EN
eCore3kW
14
Please read this instruction manual carefully before first use, and store it in
a safe place. If you pass on the product to another person, hand over this
instruction manual along with it.
Table of contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
2 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
3 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
4 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5 Reference tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
6 Switching the device on and off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
7 Configuring the device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
8 Maintaining and cleaning the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
10 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
11 Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
12 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
eCore-3kW--O--WEST.book Seite 14 Donnerstag, 4. August 2016 2:22 14
EN
eCore3kW Explanation of symbols
15
1 Explanation of symbols
D
!
!
A
I
DANGER!
Safety instruction: Failure to observe this instruction will cause fatal or
serious injury.
WARNING!
Safety instruction: Failure to observe this instruction can cause fatal or
serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to injury.
NOTICE!
Failure to observe this instruction can cause material damage and impair
the function of the product.
NOTE
Supplementary information for operating the product.
eCore-3kW--O--WEST.book Seite 15 Donnerstag, 4. August 2016 2:22 14
EN
General safety instructions eCore3kW
16
2 General safety instructions
The manufacturer accepts no liability for damage in the following cases:
Faulty assembly or connection
Damage to the product resulting from mechanical influences and excess voltage
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in the operating manual
2.1 General safety
D
DANGER!
Before you use the device for the first time, check that the operating
voltage matches the mains voltage (see type plate).
In the event of fire, use a fire extinguisher which is suitable for electrical
devices.
!
WARNING!
Do not use the device if the device itself or its connection cables are
visibly damaged.
This device may only be repaired by qualified personnel. Inadequate
repairs may cause serious hazards.
Should your device need to be repaired, please contact customer
services.
Persons whose physical sensory or mental capacities prevent them
from using this device safely should not operate it without the
supervision of a responsible adult.
Electrical devices are not toys.
Always keep and use the device out of the reach of children.
Children must be supervised to ensure that they do not play with the
device.
If a battery is connected, the device is live, even if the main switch is
turned off.
!
CAUTION!
Disconnect the device from the mains:
Before working on the device
Before cleaning and maintenance
–After use
eCore-3kW--O--WEST.book Seite 16 Donnerstag, 4. August 2016 2:22 14
EN
eCore3kW General safety instructions
17
A
NOTICE!
Check that the voltage specification on the type plate is the same as
that of the power supply.
Ensure that other objects cannot cause a short circuit on the contacts
of the device.
Ensure that the red and black terminals never come into contact.
Do not pull on the cables.
Never pull the plug out of the socket by the connection cable.
2.2 Operating the device safely
!
WARNING!
Before starting the consumer devices, make sure that the power
supply line and the plug are dry.
!
CAUTION!
Even after the fuse triggers, parts of the inverter remain live.
Do not disconnect any cables when the device is still in use.
A
NOTICE!
Never expose the device to moisture.
Make sure that none of the air inlets and outlets are blocked. If
necessary, clean the vents before you use the device.
Ensure good ventilation.
Do not connect the 230 V output of the inverter to a different 230 V
source.
2.3 Safety precautions when handling batteries
!
WARNING!
Batteries contain aggressive and caustic acids. Avoid battery fluid
coming into contact with your body. If your skin does come into
contact with battery fluid, wash the part of your body in question
thoroughly with water.
If you sustain any injuries from acids, contact a doctor immediately.
eCore-3kW--O--WEST.book Seite 17 Donnerstag, 4. August 2016 2:22 14
EN
General safety instructions eCore3kW
18
!
CAUTION!
When working on the batteries, do not wear any metal objects such as
watches or rings.
Lead acid batteries can cause short circuits which can cause serious
injuries.
Danger of explosions!
Never attempt to charge a frozen or defective battery.
Place the battery in a frost-free area and wait until the battery has accli-
matised to the ambient temperature. Then start the charging process.
Wear goggles and protective clothing when you work on batteries.
Do not touch your eyes when you are working on the battery.
Do not smoke and ensure that no sparks can arise in the vicinity of the
engine or battery.
A
NOTICE!
Only use rechargeable batteries.
Prevent any metal parts from falling on the battery. This can cause
sparks or short-circuit the battery and other electrical parts.
Make sure the polarity is correct when connecting the battery.
Follow the instructions of the battery manufacturer and those of the
manufacturer of the system or vehicle in which the battery is used.
If you need to remove the battery, first disconnect the earth
connection. Disconnect all connections and all consumers from the
battery before removing it.
eCore-3kW--O--WEST.book Seite 18 Donnerstag, 4. August 2016 2:22 14
EN
eCore3kW Intended use
19
3 Intended use
eCore 3kW (reference no. 9102900221) is the control unit of the eSystem energy
management system. eCore 3kW supplies connected power consuming devices
with 230 V and can simultaneously charge the following 12 V batteries:
Lead starter batteries
Lead gel batteries
Maintenance-free batteries
Absorbed glass mat (AGM) batteries
Lithium batteries (eStore)
Never use the device to charge other battery types (such as NiCd or NiMH).
!
!
WARNING!
Do not use the device to power medical equipment.
WARNING! Danger of explosions
Do not charge batteries with a cell short circuit. The oxyhydrogen they
produce can cause explosions.
Do not charge nickel cadmium or non-rechargeable batteries with the
charger. The cases of these batteries can burst explosively.
eCore-3kW--O--WEST.book Seite 19 Donnerstag, 4. August 2016 2:22 14
EN
Technical description eCore3kW
20
4 Technical description
4.1 General description
The device can only be connected to the following voltage sources:
12 Vg batteries
230 Vw mains voltage
The maximum power that can be taken from the AC power supply is adjustable
and is limited by the maximum mains current “MAX AC IN” (maximum 25 A)
Vehicle charging system (DC kit function)
Generator (ePower)
Each connected voltage can be converted to:
230 Vw / 50 Hz
12 V g
The device can be used as follows:
As an automatic charger (3-stage charging characteristic)
As a sine wave inverter: the device produces a pure 230 V output voltage
Power Sharing: the device powers a connected power consuming device with
230 V and simultaneously charges a battery
Uninterruptible power supply (UPS): the device powers connected power
consuming devices from a battery when the mains voltage fails
Generator, if an ePower T generator is connected
The device is operated via a control panel that has the following main functions:
Enabling and disabling the eCore system
Setting operating parameters
Monitoring operating parameters (such as battery voltage, output voltage)
Setting system parameters
eCore-3kW--O--WEST.book Seite 20 Donnerstag, 4. August 2016 2:22 14
EN
eCore3kW Technical description
21
4.2 Connections and controls
No. in
fig. 1,
page 3
Explanation/function
1 House battery connection
This connection is designed for a capacity of 2 kW.
2 Vehicle battery connection.
This connection is designed for 150 A.
3 AUX connection
This connection is for air conditioners without a CAN bus.
Two voltage free contacts provide information about the DC kit status. They
are activated when the DC kit switch is open due to low voltage thus
activating energy-saving mode of the air conditioner.
4 Serial AUX connection
This connection is for service purposes only.
5 RJ11 connection of a battery sensor
The battery sensor allows the battery temperature to be be measured and the
battery charger parameters to be adapted to the current conditions.
6 CAN BUS connections
The control panel and other eSystem components can be connected on
these three connections.
7 Connection of an eSystem generator (such as an ePower T generator)
812Vg connection
This connection is protected against short-circuit and overcurrent and it is
used for the connection of 12 Vg devices. The maximum current is 20 A.
9 Trickle charger connection
This connection is used to trickle charge the vehicle battery with 10 A. It can
be useful if the DC kit is not connected to the eCore.
10 D+ signal
The D+ signal comes from the vehicle charging system and informs the eCore
that the vehicle engine is running. It enables the DC kit function. If the
D+ signal is not connected, the DC kit function will not operate.
11 Status LED
green: Normal mode
orange: Standby mode
red: Fault
eCore-3kW--O--WEST.book Seite 21 Donnerstag, 4. August 2016 2:22 14
EN
Technical description eCore3kW
22
12 Main switch
0: Off
I: Charging, Generator, UPS or manual mode
II: On
Automatic mode (with Smart Wake-up function)
13 230 Vw mains input voltage
This connection is suitable for a supply voltage of 230 V / 50 Hz and an input
current of up to 25 A.
14 230 Vw output voltage with a 25 A protection (Short Break Output)
This connection serves as the connection for 230 Vw power consuming
devices. It is protected against overload and short circuit by thermal
protection switches.
15 230 Vw output voltage (eCore Output)
This connection serves as the connection for 230 Vw power consuming
devices. It is connected to the eCore inverter and controlled by the eCore
control logic. It is protected against overload and short circuit by the eCore
control electronic and the thermal protection switch.
16 Thermal protection switch
This switch will trip if the mains input current exceeds 25 A. It must be
activated manually when the current falls below 25 A again.
No. in
fig. 1,
page 3
Explanation/function
eCore-3kW--O--WEST.book Seite 22 Donnerstag, 4. August 2016 2:22 14
EN
eCore3kW Technical description
23
4.3 Internal components
Description of items 1 to 16: see chapter “Connections and controls” on page 21.
No. in
fig. 3,
page 4
Explanation/function
17 230 V relay
This relay disconnects the eCore power components from the mains voltage.
The contacts are closed if the eCore logic allows and if the mains voltage is
within tolerance. They are opened when the mains voltage is out of tolerance.
18 3 kW inverter
This inverter has the following tasks:
Generate 230 V / 50 Hz voltage from the 12 Vg supply when the mains
voltage is not connected or is out of tolerance.
Generate 230 V / 50 Hz voltage from the 12 Vg supply in order to
operate in parallel with the mains voltage (Power Sharing).
Supply of the DC bus and the DC/DC converter in order to operate the
eCore as a PFC rectifier (Power Factor Correction) and to charge the
battery.
19 DC bus
This is the common point of all the eCore power sources, and it is not
accessible from outside. The voltage on the DC bus is between 350 and
380 Vg.
20 2 kW rectifier
This rectifier converts the 3-phase voltage of a connected ePower T generator
into DC voltage that supplies the DC bus.
21 DC/DC converter
The DC/DC converter is divided into two parts:
The up-converter transforms the 12 Vg voltage of the battery into DC bus
voltage that supplies the inverter (max. 2 kW).
The down-converter transforms the DC bus voltage into 12 Vg voltage
that charges the house battery (max. 100 A).
22 eCore control logic
The control logic manages all the power elements, communication and all
eCore functions.
eCore-3kW--O--WEST.book Seite 23 Donnerstag, 4. August 2016 2:22 14
EN
Technical description eCore3kW
24
4.4 Control panel
The control panel operates in three modes:
Normal mode:
The display is switched on and all the LEDs of the LED light bars are lit from the
bottom to the current value.
Screensaver mode:
The display is switched off and only the LED that indicates the current value lights
up on the LED light bars.
Standby mode:
The display and all LEDs are switched off; only the standby LED flashes. In standby
mode, the system consumes only 2 mA.
When the main switch is switched to the “I” or “II” position, the control panel
switches to normal mode and opens the mode selection menu.
If no key is pressed within a minute, the control panel switches to standby mode. To
exit standby mode, press the SET button for 1 s.
Selecting an operating mode activates the eCore. If no key is pressed within a
minute, the control panel switches to screensaver mode. Press any key to exit
screensaver mode.
23 Earth relay
If the earth relay is switched on, the neutral conductor (N) of the inverter
output is connected internally to the protective earth (PE/GND).
If the earth relay is off, there is no connection between the neutral conductor
(N) and the protective earth (PE/GND).
Observe the regulations that apply in your country for this setting.
24 DC Kit switch
The DC Kit switch allows the house battery and the vehicle battery to be
switched in parallel. The DC Kit switch is closed when the D+ signal is high-
active (vehicle engine is turned on) and the vehicle battery has sufficient
supply power from the vehicle charging system. The DC Kit switch is open
when the D+ signal is low-active (vehicle engine is turned off).
No. in
fig. 3,
page 4
Explanation/function
eCore-3kW--O--WEST.book Seite 24 Donnerstag, 4. August 2016 2:22 14
/