Technical description eCore3kW
24
4.4 Control panel
The control panel operates in three modes:
• Normal mode:
The display is switched on and all the LEDs of the LED light bars are lit from the
bottom to the current value.
• Screensaver mode:
The display is switched off and only the LED that indicates the current value lights
up on the LED light bars.
• Standby mode:
The display and all LEDs are switched off; only the standby LED flashes. In standby
mode, the system consumes only 2 mA.
When the main switch is switched to the “I” or “II” position, the control panel
switches to normal mode and opens the mode selection menu.
If no key is pressed within a minute, the control panel switches to standby mode. To
exit standby mode, press the SET button for 1 s.
Selecting an operating mode activates the eCore. If no key is pressed within a
minute, the control panel switches to screensaver mode. Press any key to exit
screensaver mode.
23 Earth relay
If the earth relay is switched on, the neutral conductor (N) of the inverter
output is connected internally to the protective earth (PE/GND).
If the earth relay is off, there is no connection between the neutral conductor
(N) and the protective earth (PE/GND).
Observe the regulations that apply in your country for this setting.
24 DC Kit switch
The DC Kit switch allows the house battery and the vehicle battery to be
switched in parallel. The DC Kit switch is closed when the D+ signal is high-
active (vehicle engine is turned on) and the vehicle battery has sufficient
supply power from the vehicle charging system. The DC Kit switch is open
when the D+ signal is low-active (vehicle engine is turned off).
No. in
fig. 3,
page 4
Explanation/function