Amana 2246002 Installation, Operation & Application Manual

  • Hello! I am an AI chatbot trained to assist you with the Amana 2246002 Installation, Operation & Application Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Input:
• Voltage:18-30VAC
Output:
• Maximum:1ampperterminal(3amptotalforallterminals)
• Temperature control ranges: 45°Fto90°F(7°Cto32°C)Accuracy:±1°F(±0.5°C)
• Differential range: 1°Fto3°F(0.5°Cto1.5°C)
• System congurations:
Single-stageheat,single-stagecoolorsingle-stageheat
pump,gas,oil,electric
• Terminations:R,W,Y,O,B,G,C
Parts Diagrams
• Controls Single Stage Heating/
Cooling Systems
• Single Stage Heat Pump Systems
• Compatible with Gas, Oil or
Electric Systems
• Millivolt and Hydronic (water or
steam) System Compatible
• Mercury-Free, Environmentally
Safe
ResetSwitch
Electric/Gas
Jumper
Mode
Switch
Fan
Switch
Freeze
Switch
HighTemp.
Switch
NonHP–HP
Jumper
RCWYBOG
GAS
ELEC
SET
ROOM
LO BAT
DIFF
Lowbatterysignal
Temperature
differentialsetting
Roomtemperature
Roomtemperature
setpoint
Specifications
Important Safety Information
• Alwaysturnoffthethermostatbeforeinstalling,removing,cleaning,orservicing;turnoffthepoweratthemain
powersourcebyunscrewingfuseorswitchingoffcircuitbreaker
• Donotswitchto“Cool”ifroomtemperatureisbelow50
°
F(10
°
C);thiscoulddamageyourA/Csystemandcause
injury
• Donotinstallonvoltageshigherthan30VAC
• Allwiringmustconformtolocalandnationalbuildingandelectricalcodesandordinances
• Whilecleaning,donotgetsoapdirectlyonthermostatswitchesorLCDreadout;onlyuseadampclothwithamild
soaptowipeoutsideofthermostatcover
Package Contents/Tools Required
Package includes:Amana
®
2246002
non-programmablethermostatonbase,thermostatcover,wiringlabels,
screwsandwallanchors,batteries(ifapplicable),Installation,OperationandApplicationGuide.
Tools required for installation:Drillwith3/16”bit,hammer,screwdriver.
Installation, Operation &
Application Guide
www.amana-ptac.com
2246002
General Description
• TheAmana
®
2246002thermostatisadigital, mercury-free, non-programmable, electronic thermostat
• Compatiblewithsingle-stageheating systems, heating/cooling systems,andheat pump systems;workswith
gas, oil, or electricsystems
• Compatibleasamaster thermostatinzonedsystemapplications
• Freeze Protection Feature:Protectspipesfromfreezing!Iftheroomtemperaturedropsto40
°
F,thethermostat
automaticallyturnsontheheat;thethermostatmustbeintheHeatposition;worksevenifthebatteriesaredead
• Built-in Compressor Protection for Air Conditioners:ToprotecttheA/C’scompressor,thereisa5-minute
delaybetweenthesystemturningoffandtheA/Cstarting
• System Customization:ChooseFahrenheitorCelsiusdisplay;threeavailabletemperature differential
settings
To Remove Existing Thermostat
ELECTRICAL SHOCK HAZARD
– Turn off power at the main service panel by removing the fuse
or switching the appropriate circuit breaker to the OFF position before removing the existing
thermostat.
1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingofftheappropriatecircuit
breaker.
2. Removecoverofoldthermostat.Thisshouldexposethewires.
3. Labeltheexistingwireswiththeenclosedwirelabelsbeforeremovingwires.
4. Afterlabelingwires,removewiresfromwireterminals.
5. Removeexistingthermostatbasefromwall.
6. Refertothefollowingsectionforinstructionsonhowtoinstallthisthermostat.
To Install Thermostat
ELECTRICAL SHOCK HAZARD
– Turn off power at the main service panel by removing the fuse
or switching the appropriate circuit breaker to the OFF position before removing the existing
thermostat.
IMPORTANT:Thermostat installation must conform to local and national building and electrical codes and
ordinances.
Note:
Mountthethermostataboutvefeetabovetheoor.Donotmountthethermostatonanoutside
wall,indirectsunlight,behindadoor,orinanareaaffectedbyaventorduct.
1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingofftheappropriatecircuit
breaker.MovetheCool/OFF/HeatswitchtoOFF
.
2. MovetheFAN AUTO/ONswitchtoAUTO.
3. Toremovecover,insertandtwistacoinorscrewdriverintheslotsonthetopofthethermostat.
4. Putthermostatbaseagainstthewallwhereyouplantomountit(Besurewireswillfeedthroughthewireopening
inthebaseofthethermostat).
5. Marktheplacementofthemountingholes.
6. Setthermostatbaseandcoverawayfromworkingarea.
7. Usinga3/16”drillbit,drillholesintheplacesyouhavemarkedformounting.
8. Useahammertotapsuppliedanchorsintomountingholes.
9. Alignthermostatbasewithmountingholesandfeedthecontrolwiresthroughwireopening.
10. Usesuppliedscrewstomountthermostatbasetowall.
CAUTION!
:
Besureexposedportionofwiresdoesnottouchotherwires.
11. Tightenscrewsonterminalblock.Gentlytugwiretobesureofproperconnection.Doublecheckthateachwire
isconnectedtotheproperterminal.
12. Setthefan jumpertoelectricorgas/oil,andheatpumpjumpertoNON-HPorHP.
13. Replacecoveronthermostatbysnappingitinplace.
14. Turnonpowertothesystematthemainservicepanel.
Replacing Wiring Labels
Replacetheoldlabelswiththeenclosednewlabels:
Old New Type
F,G G Fancontrolrelay
O O Coolactivereversingvalve
B B Heatactivereversingvalve
Y,Y6 Y Coolingcontrol
H,W,4 W
Heatingcontrol
C Transformer,commonside
M,4,RH,RS,R R Transformer,hotside
C YorC
IftheCterminalisthecoolingcontrol,connecttoYterminal;ifitisthe
commonsideofthetransformer,connecttoCterminal
Non-Programmable Electronic Thermostat
Cool OnlyHeat Pump
T
H
E
R
M
O
S
T
A
T
R
C
Y
G
W
B
O
T
H
E
R
M
O
S
T
A
T
R
C
Y
G
W
B
O
T
H
E
R
M
O
S
T
A
T
R
C
Y
G
W
B
O
24VAC120VAC
HOT
Transformer
24VAC120VAC
HOT
Transformer
24VAC120VAC
HOT
Transformer
Fan
Relay
Fan
Relay
Fan
Control
Cooling
Control
Compressor
Contactor
Reversing
Valve
Compressor
Contactor
Reversing
Valve
Heat Active
Reversing Valve
Cool Active
Reversing Valve
4-Wire
Single Transformer
Placejumperbetween“W”and“Y”terminals. Millivoltsystemsmayrequirea
transformerand/oranisolation
relaytooperateproperly.
A Quick Test
CAUTION!
:
Donotswitchsystemtocoolifthetemperatureisbelow50°F(10°C).Thiscandamagethe
airconditioningsystemandmaycausepersonalinjury.
Do not short jumper across terminals on the gas valve or at the system control to test installation.
Action: SettheCool/Off/HeatswitchtoCool.Pressthedownbuttonuntilthetemperature
settingis3°Fbelowtheroomtemperature.
Result:TheA/Csystemandfanshouldturnon.
Action: SettheCool/Off/HeatswitchtoOff.
Result:TheA/Cshouldturnoff(Theremaybeafandelay).
Action: SettheCool/Off/HeatswitchtoHeat.Presstheupbuttonuntilthetemperature
settingis3°Fabovetheroomtemperature.
Result: Theheatingsystemandfanshouldturnon(Theremaybeatimedelaydependingonyour
system).
Action: SettheCool/Off/HeatswitchtoOff.
Result:Theheatingsystemshouldturnoff(Theremaybeafandelay).
Action: SettheFan Auto/OnswitchtoOn.
Result:Theblowerfanshouldturnon.
Action: SettheFan Auto/OnswitchtoAuto.
Result:Theblowerfanshouldturnoff.
Iftheabovetestwassuccessful,youhaveaproperinstallation.
If not:
Doublecheckthatwiresaresecurelyconnectedandareconnectedtotheproperterminals.Consultthe
troubleshootingsection.
Operation
Setting the Room Temperature (Setpoint Temperature)
Step 1: Pressoneofthearrowbuttons;thecurrenttemperaturesettingdisplays.
Step 2: Pressthedownoruporuparrowbuttonuntilthedesiredtemperaturesettingdisplays.
Thenewtemperaturesettingisautomaticallysaved.After5seconds,thedisplayreturnstoshowingthecurrent
roomtemperature.
Setting a New Temperature Differential
Thedefaulttemperaturedifferentialis1°.Whenyourroomtemperaturevariesby1°F,thethermostatturnsyour
systemon.Ifyounoticeyoursystemturningonandofftoofrequently,increasethetemperaturedifferential.
Step 1: ResetthermostatbypressingtheResetbuttononce.
Step 2: Fortherst10secondsofoperation,thetemperaturedifferentialisdisplayed.
Pressthedownoruparrowbuttontoselectdesiredsetting.
Starting the Thermostat
Step 1: MovetheFan Auto/OnswitchintotheAutoposition.
Step 2: MovetheCool/Off/HeatswitchtoCoolorHeat,dependingontheseason.
Troubleshooting
Symptom Remedy
Thesystemisn’tturningon Checkthewiring(seeInstallation)
LCDisblank Verify24VACisatthermostat.
Thermostatisnotproperlycontrollingthefan CheckthattheGas/Electricjumpersettingmatchesyoursystem
(gasorelectric)
Thermostatiscontinuouslyturningonandoff Increasethetemperaturedifferential
(seeSettingaNewTemperatureDifferential)
Temperaturedisplayedisnotaccurate Plugtheholeforwiringbehindthethermostatwithnon-
ammableinsulationtopreventairowintothethermostat
Wiring Diagrams
4 or 5-Wire, Single Transformer
24VAC
T
H
E
R
M
O
S
T
A
T
R
C
Y
G
120VAC
HOT
Transformer
Fan
Control
W
B
O
Heating
Control
(Optional)
Cooling
Control
Heating and Cooling
4-Wire, Single Transformer
24VAC
T
H
E
R
M
O
S
T
A
T
R
C
Y
G
120VAC
HOT
Transformer
Fan
Control
W
B
O
Heating
Control
3-Wire, Single Transformer
24VAC
T
H
E
R
M
O
S
T
A
T
R
C
Y
G
120VAC
HOT
Transformer
W
B
O
Heating
Control
Heating Only
LIAF172
/