Haworth 6100-0059 Operating instructions

Category
Telephones
Type
Operating instructions
GROUNDED
OUTLET
GROUNDED
OUTLET BOX
GROUNDED
PIN
(A) FIGURE 1
1 of 9 6100-0059 Rev:
Part No:
Page:
E.C.O. No:
CUSTOMER SERVICE PHONE: 1-800-426-8562
1245-602
Maximum functional load: 150 lbs
Power Base Electrical Rating: 208Y/120V, 120/240V or 120V 60Hz, 20A
IMPORTANT SAFETY INSTRUCTIONS
For use with HOP Electric Height Adjustable Back to Back Benches
For Commercial Use Only
This product conforms to UL Std. 962 & 1286 and is certied to
CSA Std. C22.2 No. #68 & #203
When using an electrical furnishing, basic precautions should always be followed, including the following:
Read all instructions before using this table.
DANGER - To reduce the risk of electric shock:
1. Always unplug this furnishing from the electrical outlet before cleaning.
WARNING - TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:
1. Unplug from outlet before putting on or taking o parts.
2. Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons.
3. Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recom-
mended by the manufacturer.
4. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or
damaged, or dropped into water. Return the furnishing to a service center for examination and repair.
5. Keep the cord away from heated surfaces.
6. Do not use outdoors.
7. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
8. To disconnect, turn all controls to the o position, then remove plug from outlet.
9. WARNING: RISK OF ELECTRIC SHOCK, USE ONLY SJT TYPE 18 AWG CORD AT THE APPLIANCE INLET -
CONNECT THIS FURNISHING TO A PROPERLY GROUNDED OUTLET ONLY. SEE GROUNDING INSTRUCTIONS.
SAVE THESE INSTRUCTIONS
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for
electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
DANGER - Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
Check with a qualied electrician or serviceman if you are in doubt as to whether the product is properly grounded.
Do not modify the plug provided with the product - if it will not t the outlet, have a proper outlet installed by a
qualied electrician.
This product is for use on a nominal 120-volt circuit and has a grounding plug that looks like the plug illustrated in sketch A
(see Figure 1). Make sure that the product is connected to an outlet having the same conguration as the plug. No adapter
should be used with this product.
Electrical Rating: 120V, 60Hz, 4A for 2 leg tops
A
Worksurface
245-602 2 of 9 6100-0059 1
Rev:
Part No:
Page:
E.C.O. No:
Tools Required
2mm
2.5mm
4mm
5mm & 6mm
Back to Back Height Adjustable Bench
Installation Instructions
HOP®
P
Programmable
Switch
Control Box
OR
FOR ELECTRIC TABLES
FOR ELECTRIC TABLES
CUSTOMER SERVICE PHONE: 1-800-426-8562
F
H
E
E
S-94
S-1
M
S-1
S-94
S-81
S-81
B1
B1 B
K
K
D
S-94
J
S-94
S120
S-94
S118 F
S-1
G
Worksurface
Bracket
Worksurface
Bracket
Plastic
Button
Column
Frame
Rail
Center
Rail
Frame
Beam
Angle
Bracket
Frame
Cover
Scale 1 : 1
011/2
1/4 1/4
#2
(S-94)
Socket Cap M6 X 10mm
(S-81)
Flat Head M6 X 12mm
(S118)
M6 x 30mm Socket Head Cap Screw#10 x 1" Pan Head Screw
(S-1)
#10-24 x 3/8" Screw
(S120)
#10-16 x 1/4" Screw
(S121)
M2.9 x 19mm
Pan Head Screw
(S-25)
S120
C
PDA
Bracket
C1
Communication
Bracket
S-26
S-25
M4.8 x 19 Pan Head Screw
(S-26)
245-602 3 of 9 6100-0059 1
Rev:
Part No:
Page:
E.C.O. No:
CUSTOMER SERVICE PHONE: 1-800-426-8562
1
3
2
J
(S-94)
Socket Cap M6 X 10mm
(S118)
M6 x 30mm Socket Head Cap Screw
E
E
E
E1
S118
J
S120
C
C1
#10 x 3/8" Screw
(S120)
G
MAKE SURE
HOLES ARE
ON TOP!
IMPORTANT
S-94
J
245-602 4 of 9 6100-0059 1
Rev:
Part No:
Page:
E.C.O. No:
CUSTOMER SERVICE PHONE: 1-800-426-8562
C1
C1
Ordered Separately
as power retrot kit
4
5
FOR POWER
A) All interconnected electrical
systems shall terminate with
an oce furnishings electrical
system.
B) All interconnected electrical
systems shall not have an
interconnection such that an
oce furnishings system is
rst and then followed by a
manufacturing wiring system.
C) All interconnected electrical
systems shall not alternate
between oce furnishing and
manufacturing wiring systems.
C3
C1
C1
BASE FEED
C4
C5
RECEPTACLE
JUMPER
NOTE: Install all jumpers (C3),
basefeeds (C4), and receptacle’s (C5)
before installing cable troughs (E).
1
2
C
C1
S124
#10 x 3/8" Screw
(S120)
#10-24 x 3/8" Hex
Flange Head Screw
(S124)
S120
H1
H2
245-602 5 of 9 6100-0059 1
Rev:
Part No:
Page:
E.C.O. No:
CUSTOMER SERVICE PHONE: 1-800-426-8562
7
P
P
S121
Q
6
#10 x 3/8" Screw
(S120)
#10 x 1/4" Screw
(S121)
S120
245-602 6 of 9 6100-0059 1
Rev:
Part No:
Page:
E.C.O. No:
CUSTOMER SERVICE PHONE: 1-800-426-8562
8
9
F
(S-94)
Socket Cap M6 X 10mm
(S-94)
Socket Cap M6 X 10mm
S-94
H
E
E
S-94
F
S-94
NOTE: Install screws (S-94)
hand tight only.
10
11
S-81
B1
B
(S-94)
Socket Cap M6 X 10mm
C
D
(S-81)
Flat Head M6 X 12mm
S-94
OR
REFER TO SCREEN INSTRUCTIONS
Part Number: 6100-0062
S-94
2
1
245-602 7 of 9 6100-0059 1
Rev:
Part No:
Page:
E.C.O. No:
CUSTOMER SERVICE PHONE: 1-800-426-8562
245-602 8 of 9 6100-0059 1
Rev:
Part No:
Page:
E.C.O. No:
CUSTOMER SERVICE PHONE: 1-800-426-8562
12
A
A
S-1
#10 x 1" Pan Head Screw
(S-1)
Rev:
Part No:
Page:
E.C.O. No:
CUSTOMER SERVICE PHONE: 1-800-426-8562
19 of 9245-602 6100-0059
Attach control box (C) and up/down handset (G). Reset table to lowest position.
S-26
M
P
S-25
Initial Reset
After assembly all electric tables must be calibrated to insure smooth and trouble free movement.
1. Lower the table to the lowest height by pressing the down arrow on the switch.
2. Press down again for 5 to 10 seconds after the table has reached the lowest position
NOTE: The table will readajust itself if needed.
Follow-up Calibration
1. Inform the user that the table should be recalibrated once every month by following the instruc-
tions above.
2. The table should also be recalibrated if jerky or uneven movement is noted.
14 Handset reset and calibration.
CAUTION
DO NOT PLUG POWER CORD
INTO WALL OUTLET UNTIL
LEG ASSEMBLIES AND
HANDSET ARE CONNECTED
TO CONTROL MODULE
13
M2.9 x 19mm
Pan Head Screw
(S-25)
M4.8 x 19 Pan Head Screw
(S-26)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Haworth 6100-0059 Operating instructions

Category
Telephones
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI