gefran R-A/D8 Operating instructions

Type
Operating instructions

Gefran R-A/D8 is an 8-channel analog input module that offers precise data acquisition and monitoring capabilities for various industrial applications. Here's a brief overview of its features and possible use cases:

  1. Versatile Inputs:

    • Accepts a wide range of input types, including voltage (0-10V, ±10V, 0-2V), current (0/4-20mA), and strain gauge (0-30mV, 0-100mV).
  2. High Resolution:

    • Delivers accurate measurements with a 16-bit resolution for each analog input channel.
  3. Fast Sampling:

    • Ensures timely data acquisition with a sample time of less than 100 microseconds for all channels.

Gefran R-A/D8 is an 8-channel analog input module that offers precise data acquisition and monitoring capabilities for various industrial applications. Here's a brief overview of its features and possible use cases:

  1. Versatile Inputs:

    • Accepts a wide range of input types, including voltage (0-10V, ±10V, 0-2V), current (0/4-20mA), and strain gauge (0-30mV, 0-100mV).
  2. High Resolution:

    • Delivers accurate measurements with a 16-bit resolution for each analog input channel.
  3. Fast Sampling:

    • Ensures timely data acquisition with a sample time of less than 100 microseconds for all channels.
R-A/D8
MODULE WITH 8 ANALOG INPUTS
cod. 80129C / Edit 04 - 0809 - ENG
INSTALLATION AND OPERATION MANUAL
2 • INSTALLATION AND CONNECTION
This section contains the instructions necessary for correct
installation of the GILOGIK II into the machine control panel
or the host system and for correct connection of the system
power supply, inputs, outputs and interfaces.
Before proceeding with installation read the following
warnings carefully!
Remember that lack of observation of these warnings
could lead to problems of electrical safety and electroma-
gnetic compatibility, as well as invalidating the warranty.
Qualified staff
the installation and use of the system and components are only reserved
at qualified staff.
Conform use
the system and relative components are usable exclusively to the use
previewed in the manual
In order to guarantee a correct and sure operation are indispensable that
the product comes transported, stored correctly, installed, and controlled
second the previewed modalities.
Suitable for use in pollution degree 2 environment.
Open type equipment.
Notes Concerning Electrical Safety and Electromagnetic
Compatibility:
CE MARKING: EMC Conformity (electromagnetic compatibility)
in accordance with EEC Directive 2004/108/CE. The GILOGIK II
system is mainly designed to operate in industrial environments,
installed on the switchboards or control panels of productive process
machines or plants.
Norm of applicable product EN 61131-2.
The Declaration of conformity is available on GEFRAN web:
www.gefran.com
UL listed standard: UL508 file E198546
BT Conformity (low tension)
in accordance with Directive LVD 2006/95/CE.
Advice for Correct Installation for EMC
Inputs and outputs connection
The externally connected circuits must be doubly isolated.
To connect the analogue inputs the following is necessary:
- physically separate the input cables from those of the power supply, the
outputs and the power connections.
- use woven and screened cables, with the screen earthed in one point
only.
GEFRAN S.p.A. declines all responsibility for any damage
to persons or property caused by tampering, neglect,
improper use or any use which does not conform to the
characteristics of the controller and to the indications
given in these Instructions for Use.
I1 • MAIN FEATURES
8 analog inputs configurable via software
16 bit resolution
Intercepts
Configuration of inputs via software
On board power supply for transducers
Diagnostics LEDs for power supplies and alarm
Removable connector supplied
I3 • TECHNICAL DATA
- 8 analog inputs with 16 bit A/D conversion
- Sample time <100µsec for all channels
- Digital Filter
- Power supply: via R-BUS(x) 3.3V backplane
Inputs for:
- Potentiometer min. 2k
- Differential 0...100mV, 0...30mV for strain gauge
- Linear 0...10V, ±10V, 0...2V
- Linear 0...20mA, 4...20mA
Input impedance for:
- Potentiometer > 1M
- Linear 0...10V, ±10V e 0...2V > 1M
- Strain gauge 0...30mV, 0...100mV > 1M
- Linear 0/4...20mA = 100
Accuracy of inputs better than 0,2%
Power supply for transducers and potentiometers
24VDC ± 25% 500mA max. external (fed to front terminals)
Power supply is internally distributed to the various channels:
• 10V for strain-gauge max 150mA
• 24V amplified sensors max. 500mA
Input isolation: > 2,0kV
Over-voltage on inputs for 1 ms maximum: max. 1kV
For UL: supply with class 2 device
80129C_MHW_R-A/D8_0809_ENG
80129C_MHW_R-A/D8_0809_ENG
Diagnostics
- Yellow LED presence external 24V power supplies
- Yellow LED presence power supply for transducers
- Green RUN LED with double function:
• Low frequency: work with parameters of default
• High frequency: work with parameters sets from master
- Red LED Interrupt on
- Red Fail LED module error
MECHANICAL DATA
Dimensions: 92x90x25.4 mm
Weight: 120 g. max
Attachment: snaps onto R-BUS(x)
Protection level IP20
36 pin front panel connector with spring-mounted lock
AMBIENT
CONDITIONS
Working temperature: 0...50°C
Storage temperature: -20...70°C
Humidity: max. 90% Rh not condensing
For UL: Maximum surrounding air temperature 50°C
INSTALLATION AND CONNECTIONS
Power supplies : 24Vdc ± 25% 500mA max.: Use unipolar cable 0.5mm
2
. Do not attach lug.
Field inputs:
Linear 0-10V ±10V 0-2V 0/4-20mA use 2 pin shielded cable with 0.5 mm max. cross-section. Do not attach lug.
Connect shielding directly to the grounding rod and as close as possible to the module.
Potentiometer, use 3 pin shielded cable with 0.5 mm max. cross-section. Do not attach lug. Connect shielding
directly to the grounding rod and as close as possible to the module.
Amplified sensors: use 2 or 3 pin shielded cable with 0.5 mm max. cross-section. Do not attach lug. Connect shiel-
ding directly to the grounding rod and as close as possible to the module.
Strain-gauge: use 4 or 6 pin shielded cable with 0.5 mm max. cross-section. Do not attach lug. Connect shielding
directly to the grounding rod and as close as possible to the module. To calibrate the transducer, use calibration
cables outside the module
.
Any shielding must be secured near the module on the shielding rod (see appendix) or directly
on the plate.
Potentiometer Voltage Voltage Voltage Current Amplified Strain-gauge
10V power supply 0...10V -10...+10V 0...2V 0/4...20mA sensor
on board
CH1 X X X X
CH2 X X X X
CH3 X X X X
CH4 X X X X
CH5 X X X X X
CH6 X X X X X
CH7 X X X X X
CH8 X X X X X
CONFIGURABILITY OF INPUTS
4 • CONNECTIONS
12
14
13
15
16
18
19
20
17
4
5
7
8
11
10
9
6
3
2
1
3
4
R-A/D8
12
1
3
5
7
2
4
6
8
9
0
1
12
11
3
4
11
56
11
7
8
11
9
0
12
12
22
3
4
22
56
22
7
8
22
9
0
23
12
33
3
4
33
56
33
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
2
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
GNDR4GNDR3
GNDR7
IN7
VP7
GNDR5
IN5
GND3
VP5
GNDR8
VP8
IN8
IN6
GNDR6
VP6
GND4
VP3
IN3
+24Vout1
GND1
GNDR1
+IN1
VP1
-IN1
+24Vin
VS1
+24Vout2
VP4
IN4
GND2
+IN2
GNDR2
-IN2
VP2
VS2
GNDin
Yellow LED POWER +24Vin
Yellow LED POWER Vs/Vp
Red LED INT
Green LED RUN
Red LED FAIL
Vp = Supply for potentiometer
Vs = Supply for strain gauge
-
+
-
+
-
+
-
+
-
+
-
+
+
-
+
-
-
+
-
+
-
-
+
+
-
+
1
2
3
5
9
13
11
4
6
8
10
14
12
17
19
21
18
20
22
25
27
23
29
26
28
24
30
31
33
35
32
34
36
7
channel 1
channel 2
channel 3
channel 4
channel 5
channel 6
channel 7
channel 8
+24Vout1
+24Vout2
+24Vin
GNDin
VS1
VP1
- IN1
+ IN1
GND1
GNDR1
VS2
VP2
- IN2
+ IN2
GND2
GNDR2
VP3
+ IN3
GNDR3
VP4
+ IN5
GND3
GNDR5
VP6
+ IN6
GND4
GNDR6
VP7
+ IN7
GNDR7
VP8
+ IN8
GNDR8
+24Vout1
+24Vout2
+24Vout1
+24Vout2
+24Vout1
+24Vout2
+ IN4
GNDR4
VP5
GEFRAN spa via Sebina, 74 - 25050 Provaglio d’Iseo (BS) Tel. 03098881 - fax 0309839063 - Internet: http://www.gefran.com
80129C_MHW_R-A/D8_0809_ENG
24Vdc ± 25%
500mA max
  • Page 1 1
  • Page 2 2
  • Page 3 3

gefran R-A/D8 Operating instructions

Type
Operating instructions

Gefran R-A/D8 is an 8-channel analog input module that offers precise data acquisition and monitoring capabilities for various industrial applications. Here's a brief overview of its features and possible use cases:

  1. Versatile Inputs:

    • Accepts a wide range of input types, including voltage (0-10V, ±10V, 0-2V), current (0/4-20mA), and strain gauge (0-30mV, 0-100mV).
  2. High Resolution:

    • Delivers accurate measurements with a 16-bit resolution for each analog input channel.
  3. Fast Sampling:

    • Ensures timely data acquisition with a sample time of less than 100 microseconds for all channels.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI