Bell 801S User manual

Type
User manual
Flats
Electrical Cupboard
Door Panel
Bell
First
Phone
Z
I
R
O
T
Second
Phone
Z
I
R
O
T
T
O
R
H
C
+
-
Speech
Unit
51/61
801/206
Telephone Models:
801 801S 801PS
Wiring for DC Door Entry Systems with Fail Safe Lock Releases
13:4456
-
+
CO
NO
NC
TS2000
Time Clock
System
More diagrams can be
found on our website:
www.bellsystem.co.uk/
340C
Power Supply
COIL
206
Fail
Safe
Release
Installation of Door Entry Systems
The isdesignedtobewall-mountedinaconvenientindoorlocation.
The , containing the speech unit, is available with either a surface or flush-mounting back
box. Normally this would be mounted on an outside wall near the front door, and if possible in a sheltered
location.
The is designedforuseonaninwardopening woodenframedoorfitted
withasurfaceormorticelock.Thisshouldbeinstalledwithasmallamountof playonthedooras operation
willbeimpairediftootight.
This is used in conjunction with a time-clock to allow tradesmen access
duringrestrictedhours.
For optimum speech clarity, it is strongly recommended that this system is installed
using twisted-pair telephone cable (eg type CW1308). Use one of the pairs for the R & O connections
betweenthespeechunitandthetelephone.
Connectallitemsby followingthediagramoverleaf.Itisstronglyrecommendedthat asingle
telephonebeconnectedatatimeandfullytestedbeforeproceedingtothenext.
The speechunithastwocontrolsattherearforadjustmentofspeechlevels:
VolumeA: SpeechlevelattheEntrancePanel
VolumeB: SpeechlevelattheTelephone
Iffeedbackisexperienced(ahowlorwhistle)turnbothcontrolsto'off'andthenslowlyadjusteachupinturn
untilasatisfactorylevelofspeechisattained.
Nospeech/insufficientspeech:InitiallyestablishcorrectoperationoftheSpeechUnitby
disconnectingall telephonesandre-connectingasingletelephonewithashortlengthofcable(ROTonly);
Reconnect the telephones one at a time until the fault re-appears. Note: speech will be impaired if one or
moretelephonesareleftoffthehook.
DoorEntryTelephone
Entrance panel
Model206 Electric Lock Release
Tradesman button (optional):
Cable requirements:
Installation:
Speechadjustment:
Troubleshooting:
ImportantSafetyInformation
The must be placed in a protected indoor environment such as an
electrical cupboard, close to a 240V AC electrical supply and located no further than 50
metres from the entrance panel. It must be wall-mounted onto plasterboard, wood or a
similarnon-conductivematerial.
Connections to the 240V AC mains supply must be carried out by a qualified electrician or
similar competent person, and made in accordance with accepted safety practices. Atwo-
pole switch ( as provided by a Consumer Unit or Switch-Fuse) must be included to isolate
both Live and Neutral during Installation or Maintenance . The transformer is protected by
fuses;alwaysreplacethesewiththecorrecttypeandrating.
UseonlymainscabletoBS6004orequivalent,withinthefollowingspecifiedlimits:
Power Supply Unit
Conductor Diameter:
Cable Diameter:
Min. 1.0mm (0.8mm )
2
Min. 4.0mm
Max. 2.25mm (4mm )
2
Max. 8.0mm
  • Page 1 1
  • Page 2 2

Bell 801S User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI