FEATURES
• Automaticallycomesonwhenmotionisdetected.
• Automaticallyturnslightoff.
• Photocell keeps the light off during daylight
hours.
• LEDindicatesmotionwassensed(dayornight).
REQUIREMENTS
• Thelightcontrolrequires120voltsAC.
• If you want to use Manual Override mode, the
controlmustbewiredthroughaswitch.
NOTICE:Nottobeusedonlightdimmerortimer-
controlledcircuits.
• Some electrical codes require installation by a
qualified electrician.
• Thisproductisintendedforusewiththeenclosed
gasketandwithajunctionboxmarkedforusein
wetlocations.
• Thislightxturehasbeentested/certiedusing
Lights of America LED Lamp Model Numbers
2003LEDP38-65K, 2002LEDR30-65K, and
2002LEDP30-65K.
UNPACKING
Besuretoremoveallcontentsfrompackagingand
verifyallitemsarepresentbeforeassemblingthislight
xture.Thispackageincludesthefollowingitems:
• SecurityLight
• TwoLEDPAR38lamps
(LightsofAmericaModel:2003LEDP38-65K)
• Twodecorativelampshells
• MountingStrap
• PlasticHanger
• RubberPlug
• Mountinghardware
• Wirenuts
• Owner’sManual
©2008 598-1360-00
Motion Sensor
Light Control
Model: 9700LED Series
INSTALLATION
Foreasyinstallation,selectanexistinglightwitha
wallswitchforreplacement.
Forbestperformance,mountthextureabout8ft.
(2.4m)abovetheground.NOTE:Ifxtureismounted
higherthan8ft.(2.4m),aimingthesensordownwill
reducecoveragedistance.
For eave mount only:
1. Swingthesensorheadtowardstheclampscrew
joint.
For under eave installation, the sensor head must
be rotatedasshowninthenexttwostepsforproper
operationandtoavoidtheriskofelectricalshock.
Controls
Controls
Controls
Eave Mount
Wall Mount
ClampScrew
2. Thenrotatethesensorheadclockwise180°so
thecontrolsfacedown.
Ifthesensorpopsoutoftheballjoint,loosenthe
clampscrewandpushthesensorbackintotheball
joint.Tightentheclampscrewwhendone.
2
598-1360-00
WIRING THE LIGHT CONTROL
WARNING: Turn power off at circuit breaker
or fuse.
MOUNT THE LIGHT CONTROL
1. Alignthelightcontrolcoverplateandcoverplate
gasket.Securewiththemountingbolt.
2. Alignthethreeslotsinthedecorativeshellwith
thelampholderpins.Pushtheshellinandthen
twistclockwisetolock.Repeatforothershell.
LockNut
Toavoidwaterdamageandelectricalshock,
keeplampholders30°belowhorizontal.
5. Adjustthelampholdersbylooseningthelock
nutsbutdonotrotatethelampholdersmorethan
180°fromthefactorysetting.Whenscrewingin
theoodlamps,donotovertighten.
Keeplampsat
least1"(25mm)
fromthesensor.
Donotallowthe
lampstoblock
thelens.
Lens
3. Pushtherubberplugrmlyintoplace.
4. Ifa wetlocation junctionbox wasnot used,
caulk the wall plate mounting surface with
siliconeweathersealant.
ShellSlot
1. Removetheexistinglightxture.
2. Installthemountingstrapasshownusingtwo
screwsthattyourjunctionbox.
3. Theplastichangercanbeusedtoholdthexture
whilewiring.Thesmallendoftheplastichanger
canbethreadedthroughtheholeinthecenter
ofthecoverplate.Thesmallendthengoesinto
oneoftheslotsonthemountingstrap.
4. Routethelightcontrol’swiresthroughthelarge
gasketholes.
5. Twistthejunctionboxwiresandxturewiresto-
getherasshown.Securewithwireconnectors.
White to WhiteBlack to Black
Junction box ground wire to green ground screw
on fixture.
Gasket
Mounting
Strap
MountingBolt
RubberPlug
3
598-1360-00
TESTING AND ADJUSTMENTS
1. Turn on the circuit breaker and light switch.
MotionMotion
NOTE: If xture ismountedhigher than 8ft. (2.4
m),aimingthesensordownwill reduce coverage
distance.
The detector is less sensitive to motion directly
towardsit.
Maximum Range Maximum
Coverage Angle
RANGE
1051TEST
ON-TIME
Bottom of Sensor
Avoid aiming the control at:
•Objectsthatchangetemperaturerapidly,suchas
heating vents and air conditioners.Theseheat
sourcescouldcausefalsetriggering.
•Areaswherepets or trafficmaytriggerthecon-
trol.
•Nearby large, light-colored objects reecting
lightmaytriggertheshut-offfeature.Donotpoint
otherlightsatthesensor.
70ft.
(21m)
8ft.
(2.4m)
180°
MIN MAX
Least Sensitive Most Sensitive
Sensor
3. Loosen the clamp screw
inthesensorballjointand
gentlyrotatethesensor.
4. Walkthroughthecoverage
areanotingwhereyouare
whenthelightsturnon(also,
the LED will ash several
times when motion is de-
tected). Move the sensor
headup,down,orsideways
to change the coverage
area. Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
5. AdjusttheRANGEasneed-
ed.RANGEsettoohighmay
increasefalsetriggering.
6. Secure the sensor head
by tightening the clamp
screw. Donot overtighten
thescrew.
7. Set the amount of TIME you want the lights
tostayonaftermotionisdetected(1,5,or10
minutes).
WARNING: Risk of fire. Do not aim the
lamps at a combustible surface within 3 ft.
(1 m).
Clamp
Screw
Ball Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Note:Sensorhasa1
1
/
2
minute warm up period
beforeitwilldetectmotion.Whenrstturnedon
wait1
1
/
2
minutes.
2. TurntheRANGEcontroltothemediumposition
(halfwaybetweenMINandMAX)andtheON-
TIMEcontroltotheTESTposition.
4
598-1360-00
Note: Whenrstturnedonwaitabout1
1
/
2
minutes
forthecircuitrytocalibrate.
*resetstoSecuritymodeatdawn.
OPERATION
Mode: On-Time Works: Day Night
Test
5Seconds x x
Security
1,5or10Minutes x
Manual
Override
Until Dawn* x
MANUAL MODE
AUTO
TEST
ON-TIME Switch at 1, 5, or
10 minutes
...backon.
1SecondOFF
then...
ManualOverridemodecanonly
be activated at night when the
ON-TIMEswitchissettothe1,
5,or10minuteposition.
Flipthelightswitchoffforonesec-
ondthenbackontochangefrom
SECURITY mode to MANUAL
OVERRIDEmode.
To return to SECURITY mode,
either:
•turnthelightoffforoneminute
thenturniton,or...
•daylightwillautomaticallyreset
thelighttoSECURITYmode.
MODE SWITCHING SUMMARY
Flip light switch off
for one second then
back on*
*Ifyougetconfusedwhileswitchingmodes,turn
thepoweroffforoneminute,thenbackon.Afterthe
calibrationtimethecontrolwillbeintheSECURITY
mode.
MANUAL OVERRIDE MODE
SECURITY
MODE
SPECIFICATIONS
Range ...........................Upto70ft.(21m)[varieswith
surroundingtemperature].
SensingAngle .............. Upto180°
ElectricalLoad ..............Upto 300WattMaximum
Incandescent [Up to 150
Wattmaximumeachlamp
holder]or10WattMaximum
LED(Upto5WattMaximum
eachlampholder).
BulbType ...................... Up to150Watt Maximum
PA R 3 8 Tu n g s t e n
Incandescentor5WattLED
model2003LEDP38-65K.
PowerRequirements .... 120VAC,60Hz
OperatingModes ..........TEST, SECURITY, and
MANUALOVERRIDE
ON-Timer ......................1,5,10minutes
TestTimer ..................... 5Seconds
Manual
OverrideTimer .............. Until Dawn
Range ...........................Adjustable
5
598-1360-00
TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE SOLUTION
Lights will not come
on.
1. Lightswitchisturnedoff.
2. Lampislooseorburnedout.
3. Fuseisblownorcircuitbreakeristurned
off.
4. Daylightturn-offisineffect.
5. Incorrect circuit wiring, if this is a new
installation.
6. Sensorisnotaimedtowarddesiredcover-
agearea.
1. Turnlightswitchon.
2. Checklampandreplaceifburnedout.
3. Replacefuseorturncircuitbreakeron.
4. Recheckafterdark.
5. Verifywiringiscorrect.
6. Re-aimsensortocoverdesiredarea.
Lights come on in
daylight.
1. Lightcontrolmaybeinstalledinarelatively
darklocation.
2. LightcontrolisinTEST.
1. Thextureisoperatingnormallyunderthese
conditions.
2. Setcontrolswitchto1,5,or10minutes.
Lightscomeonforno
apparentreason.
1. Lightcontrolmaybesensingsmallanimals
orautomobiletrafc.
2. Rangeissettoohigh.
1. ReduceRange.Re-aimsensor.
2. ReduceRange.
Lightsstayon
continuously.
1. Thesensormaybepickingupaheatsource
like an air vent, dryer vent, or brightly
painted,heat-reectivesurface.
2. SensorisinManualOverridemode.
1. ReduceRange.Re-aimsensor.
2. Setcontrolswitchto1,5,or10minutes.
Followmanualoverrideinstructionstoreset.
Lights ash on and
off.
1. Heatorlightfromthelampsmaybeturning
thelightcontrolonandoff.
2. Heat being reected from other objects
maybeaffectingthesensor.
3. SensorisintheTestmode.
4. Light may be leaking through the ood
lampreectors
1. Repositionthelampsawayfromthesensor.
2. ReduceRange.Re-aimsensor.
3. WhileinTESTmode,lightonlystaysonfor5
seconds.
4. Makesure the metal lamp protectors are in-
stalled.
6
598-1360-00
TWO YEAR LIMITED WARRANTY
Productwillbefreeofdefectduetoworkmanshipforaperiodoftwo(2)years.Ifproductfailswithinthe
statedlife,returndefectiveproducttoretailerofLightsofAmerica.
Warrantytermsandconditionsofretailerapply.
Warrantyandguaranteevoidifproductismisused.
Ifreplacementproductisnotavailableatretailstore,pleasereturnproductintheoriginalpackage,along
withacopyofthedatedsalesreceipt,descriptionoftheproblem,andyournameandreturnaddressto
themanufacturerattheaddresslistedbelow:
LightsofAmerica
611ReyesDrive
Walnut,CA91789
Attn:ConsumerAffairsDept.
Distributedby:
611ReyesDrive
Walnut,California91789
Tel:(800)321-8100/(909)594-7883
Fax:(909)594-6758
Website:www.lightsofamerica.com
19
598-1360-00
Notes / Notas __________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
20
598-1360-00
Notes / Notas __________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
______________________
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Heath Zenith 9700LeD User manual

Category
Security access control systems
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI