Heath Zenith 9600LED series User manual

Category
Motion detectors
Type
User manual
Dated receipt required for warranty replacement.
FEATURES
• Automaticallycomesonwhenmotionisdetected.
• Automaticallyturnslightoff.
• Photocell keeps the light off during daylight
hours.
REQUIREMENTS
• Thelightcontrolrequires120voltsAC.
• If you want to use Manual Override mode, the
controlmustbewiredthroughaswitch.
NOTICE:Nottobeusedonlightdimmerortimer-
controlledcircuits.
• Some electrical codes require installation by a
qualified electrician.
• This light xture has been tested/certied us-
ing Lights of America LED Lamp Model No.
2025LEDE12.
UNPACKING
Besuretoremoveallcontentsfrompackagingand
verifyallitemsarepresentbeforeassemblingthislight
xture.Thispackageincludesthefollowingitems:
• Lantern
• ThreeLEDLamps
(LightsofAmericaModel:2025LEDE12)
• Universalmountingbracket(X-Bar)
• Mountinghardware
• Wirenuts
• Owner’sManual
©2008 598-1338-03
Motion Sensing
Diecast Metal Lantern
Model: 9600LED Series
INSTALLATION
Forbestperformance,mountthextureabout6feet
(1.8m)abovetheground.
1. Removetwodecorativenuts.
2. RemoveX-Bar.
3. TightenmountingscrewsonX-Barngertight.
4. AttachX-Bartojunctionbox.
JunctionBox
X-Bar
DecorativeNut
LanternBase
LanternMounting
Screw
X-Bar
BracketMounting
Screw
Note:Werecommendhavinganassistanthelphold
thelanternassemblyduringthewiringprocess.
2
598-1338-03
WIRING
One Motion Light
Two Motion Lights
Recommended Grounding Method
Useagreenground“pigtail”(notprovided)and
twistoneendtogetherwiththebarexturewire
andtheboxgroundwire.Securewithawirecon-
nector.Securetheotherendofthe“pigtail”with
theGNDscrewontheX-bar.
CAUTION: DO NOT connect the RED wire
unless you want to control other lights from
the motion sensor (see Optional Wiring).
Black to black
White to white
Note:Allwiringshouldberuninaccordancewiththe
NationalElectricalCodethroughconduitoranother
acceptablemeans.Contact a qualified electrician
if there is any question as to the suitability of
the system.
WARNING: Turn power off at circuit breaker
or fuse.
Ifyouhavemetaljunctionbox,youmaynotneedthe
green“pigtail”.Ifyouareunsureaboutthegrounding
method,consultyourlocalbuildingcode.
Connectthexturewirestothewiresinthejunction
box.Twistthewirestogetherandsecurewithwire
connectors.
Black
White
Greenor
Bare
Light
Fixture
Black
White
Greenor
Bare
Light
Fixture
Light
Fixture
3
598-1338-03
Black
White
Greenor
Bare
Light
Fixture
Light
Fixture
(Standard)
Master Slave
Black
White
Greenor
Bare
Light
Fixture
Light
Fixture
Red
Red
OPTIONAL WIRING
Thisxtureisprovidedwithasensorratedfor360Watts.Sincethextureisonlyrated180Watts,180Watts
ofadditionallightingmaybecontrolledbythissensor.
Whendeterminingwhataxtureisratedfor,donotsimplylookattheratingonthelampinthexture.Look
atthemarkingwhichspeciesthemaximumlampwattageforwhichthextureissuitable.
Onceyouhaveselectedthexturestobeconnectedanddeterminedtheirmaximumratings,addtheserat-
ingsup.Forinstance,ifyouhave3xturesrated180Watts,100Watts,and75Wattsrespectively,youhave
atotalloadof355Watts.
Wiring Diagram 1 – When wiring to control a standard light fixture:Stripthemotionsensor’sredwire
andconnecttothestandardlight’sblackwire.Connectallwhitewirestogether.Totalxtureratingsmustnot
exceed360Watts(3.0A).
Wiring Diagram 2 When wiring to control another motion sensing light fixture (Master / Slave): Strip
theredwireinbothlightxtures.Connecttheredwireofthecontrolling(master)xturetotheredandblack
wiresofthecontrolled(slave)xture.Connectallwhitewirestogether.Totalxtureratingsmustnotexceed
360Watts(3.0A).
Wiring Diagram 3 When wiring so either motion light turns on the both motion lights (Master / Master):
Striptheredwireinbothlightxtures.Connecttheredwireofonexturetotheredwireofthesecondxture.
Note:Inmostinstallations,anadditionalwire(samegageasexistinghousewire)willhavetobeinstalledin
thehousetoconnectthetwoxturesasmaster/master.Connectallwhitewirestogetherandallblackwires
together.Totalxtureratingsmustnotexceed360Watts(3.0A).
Wiring Diagram 1 Wiring Diagram 2
Wiring Diagram 3
Master
Black
White
Red
Green
or Bare
Master
Light
Fixture
Light
Fixture
4
598-1338-03
FINAL ASSEMBLY
1. Pushthewiresintothejunctionbox.Makesure
noneofthewiresgetpinched.
2.
Slidethextureassemblyontothemountingscrews.
Tightendecorativenutsremovedinstep1ofInstal-
lationsectionsecurelyagainstxturebase.
JunctionBox
MountingScrew
DecorativeNut
3. Caulkaroundxturebasewithsiliconeweather
sealant.
4. InstallthethreeLEDLamps(LightsofAmerica
Model No. 2025LEDE12 included). Note:This
xture’sE12candelabrabaseuseseitherLED
Lamps(1.5Wmaximumeach) or tungsten in-
candescentType“B”bulbs(60Wattmaximum
each).
5. Insertthreadedrodofnialthroughtopcover.Slide
starwasherontorodandthreadthenutontothe
rod.Tightensecurely.
6. Place top cover onto xture and attach using
thetwodecorativenuts(included).Handtighten
only.
TopCover
DecorativeNut
3LightBulbs
(60Watt
Maximumeach)
Fixture
Assembly
Finial
StarWasher
Nut
5
598-1338-03
TESTING AND ADJUSTMENTS
1. Turn on the circuit breaker and light switch.
Note:Sensorhasa1
1
/
2
minute warm up period
beforeitwilldetectmotion.Whenrstturnedon
wait1
1
/
2
minutes.
2. Set:
ON-TIMEswitchtoTEST
SENSITIVITYdialtoMidway
3.
Walkthroughthecoverageareanotingwhereyou
arewhenthelightsturnon.InTESTmode,light
willstayonfor5secondsaftersensingmotionand
thenturnoff.
4. AdjusttheSENSITIVITYtoincreaseordecrease
therangeasneeded.Toomuchsensitivitymay
causefalsetriggeringduetoheatsourcesinthe
coveragearea(seeAdjustment of Coverage Area
or Troubleshootingsection).
5. SettheamountofON-TIMEyouwantthelightto
stayonaftermotionisdetected(5or10minutes)
or...
SettheON-TIMEtotheDUSK-to-DAWNsetting
ifyouwantthelighttostayonallnight,every
night.Thephotocellwillturnthelightoffduring
theday.
Maximum Range Maximum
Coverage Angle*
(Top View)
TEST 5
10
DUSK
MINUTES TO DAWN
+
SEN
30ft.
(9.1m)
6ft.
(1.8m)
180°
Photocell
Least Sensitive Most Sensitive
The sensor is less sensitive to motion directly
towards it and more sensitive to motion across
coveragearea.
Sensor
Motion Motion
6
598-1338-03
Note: Whenrstturnedonwaitabout1
1
/
2
minutes
forthecircuitrytocalibrate.
*resetstoSecuritymodeatdawn.
OPERATION
Mode: On-Time Works: Day Night
Test
5Seconds x x
Security
5or10Minutes x
Automatic
Override
Dusk-to-Dawn x
Manual
Override
UntilDawn* x
MANUAL MODE
AUTO
TEST
ON-TIME Switch at 5 or 10
minutes
...backon.
1SecondOFF
then...
ManualOverridemodecanonly
be activated at night when the
ON-TIMEswitchissetto the5
or10minuteposition.
Flipthelightswitchoffforonesec-
ondthenbackontochangefrom
SECURITY mode to MANUAL
OVERRIDEmode.
To return to SECURITY mode,
either:
•turnthelightoffforoneminute
thenturniton,or...
•daylightwillautomaticallyreset
thelighttoSECURITYmode.
MODE SWITCHING SUMMARY
Flip light switch off
for one second then
back on*
*Ifyougetconfusedwhileswitchingmodes,turn
thepoweroffforoneminute,thenbackon.Afterthe
calibrationtimethecontrolwillbeintheSECURITY
mode.
MANUAL OVERRIDE MODE
ADJUSTMENT OF COVERAGE AREA
Thesensoronthislightxturedetects“motion”bythe
movementofheatacrossthecoveragearea.However,
followingareexamplesofobjectsthatalsoproduce
heatandcancausethesensortotrigger:
•PoolsofWater •AirConditioners
•DryerVents •Animals
•HeatingVents •AutomobileTrafc
Ifyoususpectthataheatsourceofthistypeistrig-
geringthesensor,reducethesensitivity.
SPECIFICATIONS
Range ...........................Upto30ft.(9.1m)[varies
withsurroundingtempera-
ture].
SensingAngle .............. 180°
ElectricalLoad ..............Up to 180WattMaximum
Tungsten Incandescent
or 5 Watt Maximum LED
(Lights of America model
2025LEDE12).
BulbType ......................E12 Candelabra Base,
Type“B”,60WattMaximum
Tungsten Incandescent or
LEDmodel2025LEDE12
1.5Watt.
SensorCapacity ...........360Watt(3.0A)Maximum
TungstenIncandescent
PowerRequirements .... 120VAC,60Hz
OperatingModes ..........TEST, SECURITY, AUTO-
MATIC OVERRIDE and
MANUALOVERRIDE
ON-Timer ......................5or10minutes
TestTimer .....................5Seconds
Automatic
OverrideTimer ..............Dusk-to-Dawn
Manual
OverrideTimer ..............UntilDawn
SECURITY
MODE
7
598-1338-03
TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE SOLUTION
Lights will not come
on.
1. Lightswitchisturnedoff.
2. Lampislooseorburnedout.
3. Fuseisblownorcircuitbreakeristurned
off.
4. Daylightturn-offisineffect.
5. Incorrect circuit wiring, if this is a new
installation.
1. Turnlightswitchon.
2. Checklampandreplaceifburnedout.
3. Replacefuseorturncircuitbreakeron.
4. Recheckafterdark.
5. Verifywiringiscorrect.
Lights come on in
daylight.
1. Lightcontrolmaybeinstalledinarelatively
darklocation.
2. LightcontrolisinTEST.
1. Thextureisoperatingnormallyunderthese
conditions.
2. Setcontrolswitchto5or10minutesorDusk-to-
Dawn.
Lightscomeonforno
apparentreason.
Lightcontrolmaybesensingsmallanimalsor
automobiletrafc.
Reducesensitivity.
Lightsstayoncontinu-
ously.
1. Thesensormaybepickingupaheatsource
like an air vent, dryer vent, or brightly
painted,heat-reectivesurface.
2. SensorisinAutomaticOverrideorManual
Overridemode.
1. Reducesensitivity.
2. Setcontrolswitchto5or10minutes.
Lights ash on and
off.
1. Heat being reected from other objects
maybeaffectingthesensor.
2. SensorisintheTestmode.
1. Reducesensitivity.
2. WhileinTESTmode,lightonlystaysonfor5
seconds.
Lightdoesnotstayon
inManualmode.
Nearbylarge,light-coloredobjectsreecting
lightmaytriggertheshut-offfeature.
Donotpointotherlightsatthesensor.
8
598-1338-03
TWO YEAR LIMITED WARRANTY
Productwillbefreeofdefectduetoworkmanshipforaperiodoftwo(2)years.Ifproductfailswithinthe
statedlife,returndefectiveproducttoretailerofLightsofAmerica.
Warrantytermsandconditionsofretailerapply.
Warrantyandguaranteevoidifproductismisused.
Ifreplacementproductisnotavailableatretailstore,pleasereturnproductintheoriginalpackage,along
withacopyofthedatedsalesreceipt,descriptionoftheproblem,andyournameandreturnaddressto
themanufacturerattheaddresslistedbelow:
LightsofAmerica
611ReyesDrive
Walnut,CA91789
Attn:ConsumerAffairsDept.
Distributedby:
611ReyesDrive
Walnut,California91789
Tel:(800)321-8100/(909)594-7883
Fax:(909)594-6758
Website:www.lightsofamerica.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Heath Zenith 9600LED series User manual

Category
Motion detectors
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI