Sterling Plumbing Finesse™ Peak™ Installation guide

Type
Installation guide

This manual is also suitable for

Installation and Care Guide
Pivot Shower Door
Français, page “Français-1”
Español, página “Español-1”
1331204-2-B
Tools and Materials
Before You Begin
WARNING: Risk of serious injury. Damage before installation can result in glass shattering.
Inspect the glass and all parts for damage before installation.
WARNING: Risk of serious injury. Improper installation can result in glass shattering. Follow all
installation instructions.
WARNING: Risk of serious injury. Do not cut tempered glass. Tempered glass will shatter if cut.
WARNING: Risk of serious injury. Shower door and side panels can shatter. Regularly inspect the
glass and all parts for damage, missing, or loose parts.
WARNING: Risk of serious injury. Always wear safety glasses while cutting and drilling.
WARNING: Risk of personal injury. Do not cut the tempered glass. If the glass is cut, the glass
will shatter and may cause personal injury.
WARNING: Risk of personal injury or product damage. Unframed tempered glass should not
contact hard surfaces or it may shatter. Do not touch the edge of the tempered glass panel with the
tools or any hard objects. Do not set the unframed tempered glass directly on the floor.
IMPORTANT! This door is designed to accommodate walls that are less than 3/8 (10 mm) out of plumb.
Verify the area the door will be attached to is within 3/8 (10 mm) or better of plumb. The door may not
function properly if the wall is more than 3/8 (10 mm) out of plumb.
IMPORTANT! Leave this manual for the end user. Read these instructions before installing or using this
product.
Your new Sterling door can be installed with the door opening to either the right or left. Install the
door with the pivot side away from the showerhead for best results.
Before starting the installation, lay out and identify all of the parts. Inspect for damage.
During the installation, protect the floor of the shower with a drop cloth to avoid damage.
The shower base should be installed and prepared at this time, including finished wall materials.
Closely follow the instructions pertaining to the sealant application on the door. Sealing areas other
than those shown may cause leaking.
Two people should perform this installation.
32-Teeth
Per Inch Blade
100% Silicone
SealantMiter Box
5/16" Masonry
Bit for TileMasking Tape Tin Snips
5/16"
9/64"
1331204-2-B 2 Sterling
Parts Identification
Wall Jamb
Strike
Jamb
Bulb Seal
Latch
Panel Assembly
Bottom Seal
Threshold
Pivot Pin
Bushing
Sleeve
Pivot Jamb
1319191
Hardware Pack
Wall Jamb
Sterling 3 1331204-2-B
1. Determine the Door Configuration
IMPORTANT! Install the pivot jamb of the door on the side opposite the showerhead.
IMPORTANT! Left side pivot configuration is shown in installation steps unless otherwise indicated.
Determine whether the door will be installed in a right pivot or left pivot configuration.
Pivot Jamb
Left Pivot
Top View
Right Pivot
Showerhead
Showerhead
Pivot Jamb
1331204-2-B 4 Sterling
2. Measure and Cut the Threshold
Cover the drain with tape to prevent the loss of small parts.
Use a drop cloth to protect the shower surface.
Measure distance A between the shower walls and mark it on the threshold.
Measure 1/16 (2 mm) or the width of a saw blade from A and make a second mark on the
threshold as shown.
Cut the threshold at the second mark and file any rough edges.
A
1/16"
(2 mm)
A
A
Threshold
"A" Mark
Cut here.
A
Tape Measure
Sterling 5 1331204-2-B
3. Position the Threshold
If needed, file the ends of the threshold to fit against the shower wall. Use a coin to match and
transfer the corner radius.
Position the threshold 1/4 (6 mm) from the outside edge of the shower ledge along its entire
length. Mark the location.
Tape the threshold in place.
1/4"
(6 mm)
1331204-2-B 6 Sterling
4. Position the Wall Jambs
IMPORTANT! The wall jambs must fit tightly against the threshold and the wall.
Position the wall jambs on the threshold, flush against the threshold lip and the wall, with the
round holes facing the inside of the shower.
Plumb the wall jambs.
Tape the wall jambs securely in place and mark the jambs’ location.
Wall Jamb
Sterling 7 1331204-2-B
5. Mark the Wall Jamb Screw Holes
Mark the wall at the four slotted holes on each wall jamb and remove the wall jambs.
1331204-2-B 8 Sterling
6. Install the Wall Anchors
Drill a 5/16 hole at each marked location. Use a masonry bit for tile walls.
Install the provided wall anchors.
Repeat for the opposite wall.
Thoroughly clean the shower base, floor, threshold, and wall.
1
2
3
Sterling 9 1331204-2-B
7. Install the Wall Jambs
IMPORTANT! The round holes on the wall jambs must face the inside of the shower.
Replace the wall jamb. Align the wall jamb to the marks made previously.
Secure with the four provided #8-18 x 1-1/2 screws.
Repeat for the second wall jamb.
#8-18 x1-1/2" Screw
1331204-2-B 10 Sterling
8. Install the Latches
Using the supplied hex wrench, install two latches into the strike jamb with the provided #6-20 x
1/2 screws.
Strike Jamb
Strike Jamb Latch
#6-20 x 1/2"
Sterling 11 1331204-2-B
9. Install the Strike Jamb
IMPORTANT! Left pivot configuration shown in installation steps unless otherwise indicated.
IMPORTANT! Do not install screws until instructed.
Slide the bulb seal strip completely into the T-slot of the strike jamb.
Starting at the bottom, fit the strike jamb into the wall jamb. The strike jamb should be completely
seated on the threshold and within the wall jamb.
Strike
Jamb
Strike Jamb
Bulb Seal Strip
1331204-2-B 12 Sterling
10. Place the Setting Block
Place the setting block on the threshold, flush against the strike jamb.
Setting Block
Sterling 13 1331204-2-B
11. Assemble the Hinge Bracket
IMPORTANT! Install the bushing sleeve and pivot pin according to your door configuration: left pivot or
right pivot. See illustration.
NOTE: The door hinge panel bracket may be lubricated with soapy water to ease installation of the
bushing sleeve.
Press the pivot pin into the bottom of the hinge bracket. See illustration to verify that the pivot pin
has been installed correctly according to your door configuration.
Slightly spread the bushing sleeve and slide over the pivot pin and onto the circular portion of the
door hinge panel bracket.
Slide the bushing sleeve to the top of the door hinge panel bracket. Make sure that the bushing
sleeve does not cover the pivot pin once installed.
Bushing
Sleeve
Pivot Pin
Right Pivot InstallLeft Pivot Install
Bushing
Sleeve
Pivot Pin
Pivot Pin
Pivot Pin
1331204-2-B 14 Sterling
12. Assemble the Pivot Jamb
IMPORTANT! Left pivot configuration shown.
NOTE: The bushing sleeve may be lubricated with soapy water to ease installation of the pivot jamb.
Slide the pivot jamb onto the hinge bracket.
NOTE: The bottom of the pivot jamb should be flush with the pivot pin. There should be a gap between
the bottom of the pivot jamb and the bottom of the hinge bracket.
Pivot Jamb
Sterling 15 1331204-2-B
13. Install the Pivot Jamb
IMPORTANT! Do not install screws until instructed.
With help, begin at the top and fit the pivot jamb and panel assembly completely within the
pivot-side wall jamb.
With the pivot jamb installed, ensure that the strike end of the glass panel rests on the setting
block.
Setting
Block
1331204-2-B 16 Sterling
14. Adjust the Jambs
Make sure that the pivot jamb is fully seated within the pivot side wall jamb, and that the end of
the door panel rests on the setting block.
Move the strike jamb outward until the edge of the door panel is not more than 1/4 (6 mm) from
the strike jamb surface.
Maximum adjustment is reached when the indicator line on the strike jamb is visible.
If the maximum adjustment has been reached and the edge of the door panel is more than 1/4 (6
mm) from the strike jamb surface, move the door panel and pivot jamb outward.
Maximum adjustment of the pivot jamb is reached when the indicator line on the pivot jamb is
visible.
Ensure that both the pivot jamb and strike jamb are plumb and level, and resting on the threshold.
Indicator
Line
Indicator
Line
Pivot Jamb
Strike Jamb
1/4"
(6 mm)
Sterling 17 1331204-2-B
15. Secure the Jambs
From the inside of the shower, drill 9/64 pilot holes into the pivot jamb at the locations of the holes
in the wall jamb.
Secure the pivot jamb with the provided #8-18 x 3/8 screws through the holes.
Remove the setting block.
Verify that the door closes as desired. Adjust the strike jamb if necessary.
From the inside of the shower, drill 9/64 pilot holes into the strike jamb at the locations of the
holes in the wall jamb.
Secure the strike jamb with the provided #8-18 x 3/8 screws through the holes.
1331204-2-B 18 Sterling
16. Install the Handles
NOTE: The handle shown may differ from the one included in your shower door.
Assemble the handle using the supplied hex wrench. Do not overtighten!
NOTE: The exposed screwheads face the inside of the shower.
Sterling 19 1331204-2-B
17. Install the Bottom Seal
IMPORTANT! If the seal is misshapen when taken out of the packaging, immerse it in warm water until
it regains its proper shape.
Measure the glass panel from hinge bracket to strike jamb.
Cut the bottom seal to this length.
Starting at the hinge bracket, install the cut length of the bottom seal to the bottom edge of the
inside of the glass panel. The seal should not interfere with the bulb seal.
Cut 1-1/4 from the excess bottom seal and install to the bottom edge of the inside of the hinge
bracket.
1-1/4"
(32 mm)
1331204-2-B 20 Sterling
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Sterling Plumbing Finesse™ Peak™ Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI