  • Hello! I am an AI chatbot trained to assist you with the Danfoss EKA 183A Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
520H1010 2
520H1010 2
Installation Guide
EKA 183A with Adaptor for ERC21x Controllers
Programming guide
DKRCC.EI.RL0.I2.02 / 520H10102 | 1© Danfoss | DCS (az) | 2015.05 Installation guide | EKA 183A
Components:
ERC 21x Controller EKA 183A Adaptor with cable assembly
Ordering Number: 080G9740
Pack Contents: EKA 183A, Adaptor with cable assembly
PC settings:
Refer to the specic documentation (DKRCC.PD.R1.06.02) for further details.
Instruction for connecting to controller:
Step 1 Step 2
Connect EKA 183A to Adaptor Connect Adaptor cable with the controller
2 |DKRCC.EI.RL0.I2.02 / 520H10102 © Danfoss | DCS (az) | 2015.05Installation guide | EKA 183A
Programming the controller:
EKA 183A is used to copy settings to an ERC21X controller.
It can also be used to copy settings from one ERC controller to another ERC controller of the same type, eg. the same
software version.
Programming steps:
EKA 183A is inserted into the controller.
The controller is connected to the electricity mains.
Steps Illustration Observations and actions
1- ashes
(checking)
YELLOW
The LED will ash YELLOW when the programming is
inserted into the controller. Here it is checked whether the
data can be transferred
2 - light up constant
(await press)
YELLOW
Shortly afterwards, the LED constant light up YELLOW and
the data transfer can start
3 - to write to the
controller or
to write to the
programming key
GREEN
RED
~ 1 sec
~ 4 sec
- Pressing the button on the top of EKA (1 sec) will transfer
data from the programming key to the controller
(GREEN LED ashes)
- Pressing the button on the top of EKA (4 sec) will transfer
data from the controller to the programming key
(RED LED ashes)
4 - light up constant
(transfer nished)
CONSTANT
GREEN
The transfer has nished when the LED light up constant
green
Flashing red-green-red-green-red-green....... = fault.
If there is a fault indication, please check code no.,
SW version and Error code.
Refer to Technical brochure (DKRCC.PD.R1.06.02) for
more details
Note: refer to the specific documentation (DKRCC.PD.R1.06.02) for further details
Data Transfer:
Two methods (Mode A or Mode B) can be selected for transferring data. Modes may vary based on product and
connected device as in below table.
The default mode is set as ”Mode B, which can be used for ERC 21X series only.Refer to specic documentation
(DKRCC.PD.R1.06.02) for step by step process to change the Mode for ERC 10X and ERC 11X Series.
Product Type
Mode Setting for Programming Key
Plugged in Doking Station Connected to ERC product directly
ERC 10X Series Mode A Not applicable
ERC 11X Series Mode A Not applicable
ERC 21X Series Not applicable Mode B
/