31001

V-ZUG 31001, 31011 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the V-ZUG 31001 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the application height of the appliance?
    What accessories are included with the installation?
    What are the electrical connection requirements?
    What is the minimum air gap required beneath the appliance for ventilation?
    What are the cut-out dimensions for the appliance?
    Can an oven be installed directly beneath the appliance?
    How should the appliance be installed?
Installation instructions
Induction glass ceramic hob
Frameless, for flush installation
J31001.123-1
13.8.14
1
These installation instructions apply to the models: 31001 (GK26TIMS.2F)
Identification plate
The identification plate is located next to the connection plate.
A Affix the second identification plate (supplied) in an accessible position behind the front
of the fitted cabinet beneath the appliance.
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.
Validity
General notes
If fitting in flammable material, the guidelines and standards for low voltage installations and for the fire protection must be
strictly observed.
This appliance is considered to be suitable for use in countries having a warm damp equable climate (WDaE). It may also be
used in other countries. If used in warm damp equable climated countries, the appliance is to be supplied through a residual
current device (RCD) having a rated residual operating current not exceeding 30 mA.
Installation accessories included
Designation Article
no.
Cementing-in
instructions
J004.133
Sealing strip set H6.2142
Accessories
Designation Article no.
Steel angle set
Installation dimension 40
H6.3771
Ventilation protection plate set
For niche width 550 mm
For niche width 600 mm
H6.1082
H6.1083
Instant adhesive for the installation of the steel angle
Permabond F246, incl. activator, 50 ml tube. From Silitech AG, 3008 Berne.
B11.502
Cement set
Complete with cleaning agent, primer type 1105, cartridge with silicon adhesive, black with nozzle.
Suitable for all absorbent worktop materials (wood and natural stones such as marble or granite).
86.3928.85
Special primer, type 107
Suitable for non-absorbent worktop materials (not suitable for polyethylene, polypropylene or Teflon).
45.2771.76
Connection plate
Identification plate
Installation instructions
Induction glass ceramic hob
Frameless, for flush installation
J31001.123-1
13.8.14
2
A Refer to the identification plate for specifications for the required mains voltage, current type and fuses.
A Application height of the appliance: up to max. 2000 m above sea level
A The appliance is equipped with a mains cable that should be connected to a distribution box by the customer.
Error message U400
Indications
The worktop must be flat.
In order to guarantee good ventilation, a space of at least 17.5 mm height is necessary beneath the appliance.
An oven with a height of 762 mm can be installed directly beneath a worktop with a depth of 30 mm. Exception: M-SL[P].
It is to possible install an oven in the short mounting forms 55-600, 60-600, 55-381, 60-381 or 60-450 beneath the appliance if you
use a ventilation grille set (oven accessories).
A cabinet unit with a width of at least 275 mm is recommended for the base unit.
Electrical connections
Electrical connections must made by trained electricians in accordance with the guidelines and standards for low voltage
installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should
always be checked.
Incorrect connection:
A pole conductor was connected to the connecting terminal for neutral conductors.
Quickly disconnect the appliance from the mains!
Installation
600/550/275
Installation pipe
Distribution box
Clamp
230 V~
PE/
N
L1
blue
1/black
brown
2/black
green/yellow
Installation instructions
Induction glass ceramic hob
Frameless, for flush installation
J31001.123-1
13.8.14
3
Installing
1. Create an accurate installation cut-out.
The mounting surface can be recessed by installing wood or stone bars or produced using the steel angle set (see «Accessories»).
2. Prepare the cut-out and the appliance according to the information in the accompanying cementing-in instructions.
3. Carefully cement the appliance in place and allow the silicon cement joints to dry for at least 24 hours.
4. Where necessary establish the mains supply connection before inserting the appliance.
Cool air supply if installed over a drawer or cabinet
In order to guarantee good ventilation, a space of at least 17.5 mm height is necessary beneath the appliance.
Access to the appliance from below must be guaranteed over the entire cut-out surface. For servicing, the induction
generator with the mounting plate can be removed from below. The covers to prevent accidental contact with live parts
must be removable by unscrewing from underneath.
(
3
7
3
)
(4
9
0
)
R5
R0–5
Detail Z
Steel angle bonded or screw mounted
(for adhesive see «Accessories»)
8.
5
±
0.
5
8.
5
±
0.
5
8
.5
8
.5
0
-
1
0
-
0
.
5
min. 20
Drawer/cabinet
5050
3
8
4
5
0
1
z
3
9
0
±
1
min
. 4
1
.
5
5
0
7
±
1
m
in
. 4
1
.
5
6
0
0
(30)
=
=
6
0
0
/
5
5
0
Fan
min. 15
50(17.5)
min. 5
min. 67.5
(30)
600/500
Hobs with dial controls require protective intermediate base.
Drawer or cabinet
Air gap over entire width of
cabinet element min. 25 cm²
Necessary space below
work surface for ventilation
Installation instructions
Induction glass ceramic hob
Frameless, for flush installation
J31001.123-1
13.8.14
4
Installing the protective plate with a 3 mm ventilation gap at the front (see Accessories)
A protective plate is necessary for the adequate ventilation of the hob.
The distance between the underside of the appliance and the protective plate must be at least 17.7 mm.
A protective plate cannot be installed with induction hobs that have dial controls.
ø4
393
According
to template
Air gap over entire
cabinet width min. 17 cm
2
Well-fitting seal
over cabinet width
Caution:
Do not put mains cable
near protective plate
50
(17.5)
min. 15
56
m
a
x.
0
.
5
5..10
min. 67.5
55.5
(30)
min. 3
(2.5)
Drawer
Fan
/