1 Installing the outdoor unit ...........................2
1.1 Check the delivery ..........................................2
1.2 Assembling the stand .......................................2
1.3 Preparing the outdoor unit ..................................2
1.4 Assembling the outdoor unit on the stand . . . . . . . . . . . . . . . . . . .3
1.5 Assembling the front cover ..................................3
1.6 Assembling the cover and cover plate .......................4
1.7 Assembling the defrost sensor...............................5
1 Installing the outdoor unit
It is essential that the outdoor unit is installed by two people.
1.1 Check the delivery
The outdoor unit is delivered as three items:
the outdoor unit, on a wooden pallet
a box containing the stand, adjustable feet and all the necessary screws
a box containing covers
The following tools are required for assembly and installation:
Wrench, or equivalent, 10 mm
Wrench, or equivalent, 13 mm
Screwdriver, or equivalent, torx TX25
Cross head screwdriver
Drill bit Ø 3 mm
Milling cutter Ø 6 mm, or equivalent
Drill
Check that the following screws have been supplied:
8 x M6x10, hex screw
4 x M6x10, hex screw
5 x M6x15, torx TX25
2 x panel screws, crosshead
1.2 Assembling the stand
1. Screw the two horizontal struts together (1) using the two ends (2) as illustrated below. Use 8 x M6x10 screws. The bent
edges of the horizontal struts must be facing upwards and inwards.
Figure 1: Assembling the stand.
2. Screw the adjustable feet (3) into the holes under the ends.
1.3 Preparing the outdoor unit
While the outdoor section remains on the pallet it should be prepared for placing on the stand. Carry out the following:
3. There are three M6x20 screws on the lower edge of the outdoor unit. Unscrew them so that 2-3 mm of the thread
remains. Use a torx TX25 screwdriver, or equivalent.
4. Raise the outdoor unit. NOTE! Do not lift the side plates.
5. Remove the side plates. They are held in place by clamps and so are removed by pulling outwards.
6. Remove all four screwed lifting eyes. Use a 13 mm wrench, or equivalent.
1
1
2
3
3
2
Slit
Slit
Bent edge
3
VMBMF102
1.4 Assembling the outdoor unit on the stand
7. Lift the outdoor unit into the place on the stand.
Figure 2: Lift the outdoor unit onto the stand.
8. Screw the outdoor unit onto the stand. Use 4 x M6x20 screws. It may be necessary to push and pull the stand slightly in
order to get the screw holes to align.
9. Reinstall the side panels.
1.5 Assembling the front cover
10. Hook the lower edge of the front cover onto at least one of the three screws in the bottom edge of the stand.
11. Secure the upper edge of the front panel temporarily in the centre hole. Use 1 x M6x15 torx TX25.
12. Align all the three screws in the lower edge.
13. Screw the three screws in the lower edge fully. Use a torx TX25 screwdriver, or equivalent.
4
VMBMF102
14. Secure the upper edge of the front cover.
There are two ways to secure the upper edge of the front panel:
Alternative 1: Expand the two outermost holes 2 to 3 mm towards the outer edge using a
Ø 6 mm milling cutter, or equiva-
lent, see figure 3. Use all 5 x M6x15 torx TX25.
Figure 3: Secure the cover.
Alternative 2: Use only the three screws screwed into the outdoor unit, see figure 4. Use only 3 x M6x15 torx TX25.
Figure 4: Secure the cover.
1.6 Assembling the cover and cover plate
15. Hook the cover at the front edge on the front cover.
Figure 5: Hook the front cover into place.
5
VMBMF102
16. Secure the cover using a screw on each side. Use 2 x cross head screws.
If the cover does not align with the side cover plates it may be necessary to drill new Ø 3 mm holes:
Mark for the new holes
Lift off the cover
Drill the holes
Install and screw the cover into place
Figure 6: Screw the front cover into place.
17. Hook the cover onto the stand.
Figure 7: Hook the cover into place.
1.7 Assembling the defroster sensor
18. Hook the defroster sensor onto the reverse of the outdoor unit.
The outdoor unit is now mounted and can be adjusted on the site where it should be set up.