Anolis ArcSource Outdoor 4MC Pixel User manual

Type
User manual

Anolis ArcSource Outdoor 4MC Pixel is a versatile outdoor lighting solution offering a range of mounting options for various applications. It features adjustable heads for precise positioning, allowing you to direct light exactly where you need it. With its robust construction and IP66 rating, this luminaire is suitable for withstanding harsh outdoor conditions. The ArcSource Outdoor 4MC Pixel is ideal for illuminating landscapes, architectural features, and other outdoor areas, providing both functional and decorative lighting.

Anolis ArcSource Outdoor 4MC Pixel is a versatile outdoor lighting solution offering a range of mounting options for various applications. It features adjustable heads for precise positioning, allowing you to direct light exactly where you need it. With its robust construction and IP66 rating, this luminaire is suitable for withstanding harsh outdoor conditions. The ArcSource Outdoor 4MC Pixel is ideal for illuminating landscapes, architectural features, and other outdoor areas, providing both functional and decorative lighting.

INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com
VERSION 2.0 / 02_2022
1
Fixture must be installed by a qualied electrican in accordance with all national and local electrical
and construction codes and regulations. This device falls under class one and must be grounded!
STEP 1
FIXTURE'S HOUSING
Three holes of diameter 4.3mm in the base serve for mounting
on the non-ammable surface. The luminaire head can be adjusted in range of 120°. Loosen
a locking screw M5x12, tilt it to desired position and tighten
the screw.
1 2
INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com
VERSION 2.0 / 02_2022
2
STEP 2B
INSTALL WITH STANDARD BASE AND ADAPTOR
Fasten the base of luminaire into the mounting surface with
three screws.
Assemble the 31mm adaptor between the luminaire and the
base. Locking pin of the adaptor has to placed correctly into
matching part of the luminaire. Screw the luminaire, adaptor
and base together with M5x45, spring washer and standard
washer.
Unscrew M5x14 from the bottom part of base and disassemble
the base from the luminaire.
1
2 3
STEP 2A
INSTALL WITH STANDARD BASE
Fasten the base of luminaire into the mounting surface with
three screws.
1. standard washer
2. spring washer
3. screw
INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 2.0 / 02_2022
3
STEP 2C
INSTALLATION OF 100MM ADAPTOR STAND AND MOUNTING
Unscrew M5x14 from the bottom part of base and disassemble
the base from the luminaire. Screw the 100mm adaptor into luminaire by bolt on adaptor.
Fasten the base to the adaptor with original M5x14 screw and
washers.
Fasten the base of luminaire into the mounting surface with three screws.
1 2
3
1. standard washer
2. spring washer
3. screw
INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 2.0 / 02_2022
4
STEP 2D
INSTALL WITH LAND SPIKE OR FLOOR STAND
Floor
Stand
Land Spike
Insert the Land Spike into ground. Underground part of Land
Spike should be placed perpendicularly into the ground. (if
you need to use tools to insert spike in the ground, use of
some protective layer, and applying pressure in the middle is
recommended to prevent damaging of land spike)
Fasten the Floor stand into the mounting surface by four
screws and prepared mounting holes.
INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 2.0 / 02_2022
5
1.Insert the Land Spike into the ground. Underground part
of Land spike (1) should be placed perpendicularly into the
ground. (if you need to use tools to insert spike in the ground,
use of some protective layer and applying pressure in the mid-
dle is recommended to prevent damaging of land spike).
2. Screw the threaded bar (2) into the top of underground part
(1) and fasten it with the socket head M5x5 (3).
3. Slide the cover (4) on the treaded bar (2).
4. Slide the 36.5mm pipe cover (5) on the threaded bar (2).
5. Slide the cable holder (6) on the threaded bar (2).
6. Screw the nut with mount (7) on the threaded bar (2).
7. Fasten the luminaire on the mount (7) with one M5x14 screw
from the bottom of luminaire.
8. Pass cable through the cable holder (6).
1.Insert the Land Spike into the ground. Underground part
of Land spike (1) should be placed perpendicularly into the
ground. (if you need to use tools to insert spike in the ground,
use of some protective layer and applying pressure in the mid-
dle is recommended to prevent damaging of land spike).
2. Screw the threaded bar (2) into the top of underground part
(1) and fasten it with the socket head M5x5 (3).
3. Slide the cover (4) on the treaded bar (2).
4. Slide the 36.5mm pipe cover (5) on the threaded bar (2).
5. Slide the cable holder (6) on the threaded bar (2).
6. Slide the 36.5mm pipe cover (5) on the threaded bar (2).
7. Slide the ArcSources holder (8) on the threaded bar.
8. Screw the nut (9) on the treaded bar.
9. Fasten both luminaires to the holder (8) with M5x14 screws
from the bottom of each luminaire and its mount on the hol-
der.
10. Pass the cable through the cable holder (6).
Land spike 1 ASO 4 MC Pixel 100 mm Land spike 2 ASO 4 MC Pixel 100 mm
INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 2.0 / 02_2022
6
1.Underground part of Land spike (1) should be placed perpendicu-
larly into the ground. (if you need to use tools to insert spike in the
ground, use of some protective layer and applying pressure in the
middle is recommended to prevent damaging of land spike)
2. Screw the threaded bar (2) onto the underground part of spike (1)
and fasten it with the socket head M5x5 (3).
3. Slide the cover (4) on the treaded bar (2) and the socket head (3).
4. Slide the 36.5mm pipe cover (5) on the threaded bar (2).
5. Slide the cable holder (6) on the threaded bar (2).
6. Slide the 198mm pipe cover (7) on the threaded bar (2).
7. Slide the cable holder (6) on the threaded bar (2).
8. Slide the 198mm pipe cover (7) on the threaded bar (2).
9. Slide the cable holder (6) on the threaded bar (2).
10. Screw the nut with mount (8) on the threaded bar (2).
11. Fasten the luminaire on the mount (8) with one M5x14 screw from
the bottom of luminaire and its mount.
12. Pass cable through the cable holders (6).
1.Underground part of Land spike (1) should be placed perpendicu-
larly into the ground. (if you need to use tools to insert spike in the
ground, use of some protective layer and applying pressure in the
middle is recommended to prevent damaging of land spike)
2. Screw the threaded bar (2) onto the underground part of spike (1)
and fasten it with the socket head M5x5 (3).
3. Slide the cover (4) on the treaded bar (2) and the socket head (3).
4. Slide the 36.5mm pipe cover (5) on the threaded bar (2).
5. Slide the cable holder (6) on the threaded bar (2).
6. Slide the 198mm pipe cover (7) on the threaded bar (2).
7. Slide the cable holder (6) on the threaded bar (2).
8. Slide the 198mm pipe cover (7) on the threaded bar (2).
9. Slide the ArcSources holder (8) on the threaded bar (2).
10. Screw the nut (9) on the threaded bar (2).
11. Fasten both luminaires to the holder (8) with M5x14 screws from
the bottom of each luminaire and its mount.
12. Pass cables through the cable holder (6).
Land spike 1 ASO 4 MC Pixel 500 mm Land spike 2 ASO 4 MC Pixel 500 mm
INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 2.0 / 02_2022
7
1.Underground part of Land spike (1) should be placed per-
pendicularly into the ground. (if you need to use tools to insert
spike in the ground, use of some protective layer and applying
pressure in the middle is recommended to prevent damaging
of land spike)
2. Screw the threaded bar (2) onto the underground part of
spike (1) and fasten it with the socket head M5x5 (3).
3. Slide the cover (4) on the treaded bar (2) and the socket
head (3).
4. Slide the 36.5mm pipe cover (5) on the threaded bar (2).
5. Slide two cable holders (6) on the threaded bar (2).
6. Slide the 198mm pipe cover (7) on the threaded bar (2).
7. Slide the ArcSources holder (8) on the threaded bar (2).
8. Slide the 198mm pipe cover (7) on the threaded bar (2).
9. Slide the cable holder (6) on the threaded bar (2).
10. Screw the nut with mount (9) on the threaded bar (2).
11. Fasten three luminaires to their holders (8,9) with M5x14
screws from the bottom of each luminaire and its mount.
12. Pass cables through the cable holders (6).
Land spike 3 ASO 4 MC Pixel 500 mm
INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 2.0 / 02_2022
8
STEP 3
CONNECTION
T-connector
Male connector
Female connector
Connect luminaires to each other and to power supply via
T-connectors and cables.
Recommended power supplies:
ArcPixel Rack Unit, ArcPixel Power.
Connection of ArcSource Outdoor 4MC Pixel is provided by
50cm long cable with male connector. (variety of cable adap-
tors is available)
Before ASO 4MC Pixel are connected to power source, you
have to connect the Active Terminator on the last luminaire in
the row. That is necessary for correct identication of every
single ASO 4MC Pixel and this has to be done for setup of eve-
ry ASO 4MC Pixel row. You can change the Active Terminator
box for Passive Terminator box, when the set up is nished.
Passive Terminator
Active Terminator
INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 2.0 / 02_2022
9
Half Top Hat and Top Hat
STEP 4
INSTALLATION ACCESSORIES
Top HatHalf Top Hat
Unscrew the Allen head screw M5x12 from the ArcSource
Outdoor 4MC Pixel housing and its base. Screw the half top hat to luminaire body as is shown at the
picture above.
The accessories must be tighted between two washer. Co-
rrect position of the spring washer is in touch with bolt head.
1 2
INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 2.0 / 02_2022
10
Twin Wall Cover (Flat / Round)
Flat Round
Unscrew four M3x6 screws from Twin Wall Cover and remove
the cover from the luminaires base holder.
1 2
3 4
Prepare openings for cables in the mounting surface, minimal
diameter of 21mm, and if necessary also two mounting holes
according to disposition above.
Fasten the luminaires (without their bases) to the holder with
two M5x12 screws via two outer mounting holes. Fasten the holder with luminaires to the mounting surface via
two inner holes and fasteners suitable to mounting surface.
INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 2.0 / 02_2022
11
Twin Wall Cover (Flat / Round)
5 6
Slide the cover on the luminaires holder mounted on the sur-
face. Fasten the cover to the holder by four M3x6 screws.
Pipe Clamp diameter 19
Unscrew M5x14 from the bottom of luminaire and remove its
base. Fasten the Pipe Clamp to the luminaire with M5x14 as illustra-
ted.
Place the Pipe Clamp on a construction rod of 19mm in dia-
meter. Fasten the Pipe Clamp to the construction rod by MX screw
until it is tightened well and holds luminaire rmly.
1 2
3 4
INSTALLATION INSTRUCTIONS
ARCSOURCE OUTDOOR 4MC PIXEL
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 2.0 / 02_2022
12
Optical Demo Set
1
2
Put the Optical Foil on the luminaire's optic.
Press the springs of the Holder together, place the Holder on
top of the Optical Foil and secure it on the luminaire by relea-
sing the springs.
Holder with spring clips and Optical foil
ArcSource Outdoor 4MC Pixel with Optical Demo Set in-
stalled. Holder secures the Optical Foil on the luminaire rmly.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Anolis ArcSource Outdoor 4MC Pixel User manual

Type
User manual

Anolis ArcSource Outdoor 4MC Pixel is a versatile outdoor lighting solution offering a range of mounting options for various applications. It features adjustable heads for precise positioning, allowing you to direct light exactly where you need it. With its robust construction and IP66 rating, this luminaire is suitable for withstanding harsh outdoor conditions. The ArcSource Outdoor 4MC Pixel is ideal for illuminating landscapes, architectural features, and other outdoor areas, providing both functional and decorative lighting.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI