Alto-Shaam 10.18 User manual

Category
Ovens
Type
User manual
ES ELECTRIC
S ERI ES
610
1010
714
1018
1220
2020
VH ES-5
VH ES-10
C o m b i n a t i o n
O v e n / S t e a m e r
#MN-28677 08/08
W164 N9221 Water Street P.O. Box 450 Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3800 800.558.8744 USA/CANADA FAX: 262.251.7067 800.329.8744 U.S.A. ONLY
WWW
.ALTO-SHAAM.COM
PRINTED IN U.S.A.
I N STALLATION
General Information
Delivery / Unpacking . . . . . . . . . . . . . . . . . .1.
Safety Procedures and Precautions . . . . . . . . .2.
Specifications
Options . . . . . . . . . . . . . . . . . . . . . . . . . . .3.
610es . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.
610esi . . . . . . . . . . . . . . . . . . . . . . . . . . .5.
610esiN . . . . . . . . . . . . . . . . . . . . . . . . . .6.
1010es . . . . . . . . . . . . . . . . . . . . . . . . . . .7.
1010esi . . . . . . . . . . . . . . . . . . . . . . . . . .8.
1010esiN . . . . . . . . . . . . . . . . . . . . . . . . .9.
714es . . . . . . . . . . . . . . . . . . . . . . . . . . .10.
714esi . . . . . . . . . . . . . . . . . . . . . . . . . .11.
1018es . . . . . . . . . . . . . . . . . . . . . . . . . .12.
1018esi . . . . . . . . . . . . . . . . . . . . . . . . .13.
1220es . . . . . . . . . . . . . . . . . . . . . . . . . .14.
2020es . . . . . . . . . . . . . . . . . . . . . . . . . .15.
Installation Requirements
Installation Codes & Standards . . . . . . . . . . .16.
Ventilation General Requirements . . . . . . . . .17.
Positioning on Site . . . . . . . . . . . . . . . . . . .17.
Minimum Clearance Requirements . . . . . . . .17.
Positioning Requirements . . . . . . . . . . . . . .18.
Electrical Requirements . . . . . . . . . . . . . . . .19.
Drip Tray Installation . . . . . . . . . . . . . . . . .20.
Mobile Equipment Restraint . . . . . . . . . . . . .20.
Water Quality Requirements . . . . . . . . . . . . .21.
Water Connection . . . . . . . . . . . . . . . . . . .22.
Water Filtration System . . . . . . . . . . . . . . . .23.
Water Drainage . . . . . . . . . . . . . . . . . . . . .24.
Installation Checklist . . . . . . . . . . . . . . . . .25.
Error Codes
Control Reset . . . . . . . . . . . . . . . . . . . . . .26.
Service Mode and Error Codes . . . . . . . . . . .26.
Emergency Operation . . . . . . . . . . . . . . . . .29.
Ventless Hood Option
Condensate Drain . . . . . . . . . . . . . . . . . . . .30.
Opening Mechanism . . . . . . . . . . . . . . . . . .30.
Operation . . . . . . . . . . . . . . . . . . . . . . . . .31.
Interlock Switches . . . . . . . . . . . . . . . . . . .31.
Reset Switch . . . . . . . . . . . . . . . . . . . . . . .31.
Cleaning and Maintenance . . . . . . . . . . . . . .32.
Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.
Equipment Limited Warranty . . . . . . . . . . .33.
Transportation Damage and Claims . . . . . .34.
D E L I V E R Y
This Alto-Shaam appliance has been
thoroughly tested and inspected to insure only the
highest quality unit is provided. Upon receipt,
check for any possible shipping damage and report
it at once to the delivering carrier. See
Transportation Damage and Claims section
located in this manual.
This appliance, complete with unattached
items and accessories, may have been delivered in
one or more packages. Check to ensure that all
standard items and options have been received
with each model as ordered.
Save all the information and instructions
packed with the appliance. Complete and return
the warranty card to the factory as soon as
possible to assure prompt service in the event of a
warranty parts and labor claim.
This manual must be read and understood by
all people using or installing the equipment
model. Contact the Alto-Shaam service
department if you have any questions concerning
installation, operation, or maintenance.
NOTE: All claims for warranty must include the
full model number and serial number of
the unit.
U N P A C K I N G
1. Carefully remove the
appliance from the
carton or crate.
NOTE: Do not discard the
carton and other
packaging material
until you have
inspected the unit
for hidden damage
and tested it for
proper operation.
2. Read all instructions in this manual carefully
before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the
appliance and is to be provided to the owner or
manager of the business or to the person
responsible for training operators. Additional
manuals are available from the Alto-Shaam
service department.
3. Remove all protective plastic film, packaging
materials, and accessories from the appliance
before connecting electrical power. Store any
accessories in a convenient place for future use.
®
®
®
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 1
LES INFORMATIONS CONTENUES DANS CE
MANUEL SONT IMPORTANTES POUR
L'INSTALLATION L'UTILISATION ET
L'ENTRETIEND DE CE FOUR. S'IL VOUS
PLAIT LISEZ-LE TRES ATTENTIVEMENT ET
CONSERVEZ-LE.
LA NON-APPLICATION DE CES CONSIGNES
ANNULE TOUTES GARANTIES.
THE INFORMATION CONTAINED IN THIS
MANUAL IS IMPORTANT FOR THE PROPER
INSTALLATION OF THIS OVEN. PLEASE
READ CAREFULLY AND RETAIN FOR
FUTURE REFERENCE.
IMPROPER CONNECTION OF THIS
APPLIANCE WILL NULLIFY ALL
WARRANTIES.
C A U T I O N
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
1. This appliance is intended to cook, hold or
process foods for the purpose of human
consumption. No other use for this appliance is
authorized or recommended.
2. This appliance is intended for use in commercial
establishments where all operators are familiar
with the purpose, limitations, and associated
hazards of this appliance. Operating
instructions and warnings must be read and
understood by all operators and users.
3. Any troubleshooting guides, component views,
and parts lists included in this manual are for
general reference only and are intended for use
by qualified technical personnel.
4. This manual should be considered a permanent
part of this appliance. This manual and all
supplied instructions, diagrams, schematics,
parts lists, notices, and labels must remain with
the appliance if the item is sold or moved to
another location.
N O T E : Used to notify personnel of
installation, operation, or
maintenance information that is
important but not hazard related.
C A U T I O N
Used to indicate the presence of a hazard that can
or will cause minor personal injury, property
damage, or a potential unsafe practice if the
warning included with this symbol is ignored.
C A U T I O N
Used to indicate the presence of a
hazard that can or will cause minor or
moderate personal injury or property
damage if the warning included with
this symbol is ignored.
D A N G E R
Used to indicate the presence of a
hazard that WILL cause severe
personal injury, death, or substantial
property damage if the warning
included with this symbol is ignored.
W A R N I N G
Used to indicate the presence of a
hazard that CAN cause personal injury,
possible death, or major property
damage if the warning included with
this symbol is ignored.
SAFETY PROCEDURES
AND PRECAUTIONS
Knowledge of proper procedures is essential to the
safe operation of electrically and/or gas energized
equipment. In accordance with generally accepted
product safety labeling guidelines for potential
hazards, the following signal words and symbols
may be used throughout this manual.
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 2
C A U T I O N
WHEN WELDING ANY STAINLESS
STEEL COMPONENTS ON THIS
APPLIANCE, THE ELECTRONIC
CONTROL BOARDS MUST BE
ISOLATED FROM THE APPLIANCE.
N O T E
For equipment delivered for use
in any location regulated by the
following directive:
DO NOT DISPOSE OF ELECTIRCAL
OR ELECTRONIC EQUIPMENT WITH
OTHER MUNICIPAL WASTE.
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 3
®
COMBITHERM
COMMON SPECIFICATIONS
CombiGuard Triple-Guard Water Filtration System
(INCLUDES 1 CARTRIDGE) FI-23014
CombiGuard Replacement Filter F
I-26356
Fry Basket, 12" X 20" (325mm x 530mm) BS-26730
Grilling Grate,
12" X 20" (325mm x 530mm) SH-26731
Oven Cleaner CE-24750
SPECIALLY FORMULATED FOR COMBITHERM OVENS
TWELVE (12) CONTAINERS/CASE, 1 QUART (C. 1 LITER) EACH
Scale Free CE-27889
(
CITRUS BASED, NON-CORROSIVE DELIMING PRODUCT)
CASE = FOUR 4-LB BOTTLES; 4-LB BOTTLE MAKES 10 GALLONS
Service Start-Up Check SPECIFY AS REQUIRED
AVAILABLE THROUGH AN ALTO-SHAAM FASTEAM CENTER
Computer Software Options 5005676
Not available on S-Control Models.
REFER TO HACCP SPECIFICATION SHEET #9015
FOR APPLICABLE PART NUMBERS
HACCP Documentation
HACCP Documentation with Kitchen Management
Wireless HACCP Documentation with
Kitchen Management
IEEE 802.11b STANDARDS
Six (6) Chicken Roasting Rack
(PAN NOT INCLUDED) SH-23000
Fry Basket BS-26730
Grilling Grate SH-26731
Ten (10) Chicken Roasting Rack
SH-22634
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 4
®
COMBITHERM
6•10E
S
SPECIFICATIONS
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Six (6)
GN 1/1: 530 x 325 x 65mm Six (6)
HALF-SIZE SHEET PANS:* 18" x 13" x 1" Six (6)
ON WIRE SHELVES ONLY
72 lb (33 kg) MAXIMUM
VOLUME MAXIMUM
: 45 QUARTS (57 LITERS)
W E I G H T
NET 360 lb (163 kg)
SHIP 484 lb (220 kg)
CRATE 40" X 48" X 40" EST.
DIMENSIONS: (1016 x 1219 x 1016mm)
E L E C T RI C A L
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW
at 208 1* 50/60 2 Wire plus ground 40.5 8.4
at 240 AWG 6 47.0 11.2
at 208 3 50/60 3 Wire plus ground 23.5/ph 8.4
at 240 AWG 8 27.0/ph 11.2
at 380 3 50/60 4 Wire plus ground 13.0/ph 8.4
at 415 AWG 12 16.0/ph 11.2
at 440 3* 50/60 3 Wire plus ground 20.0/ph 15.4
at 480 AWG 8 22.0/ph 18.4
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
208-240
380-415
440-480
31-3/8" (796mm)
34-1/16" (864mm)
17-15/16"
(456mm)
7
-9/16"
(191mm)
WATER
D
RAIN
33-1/8" (840mm)
4-15/16"
(125mm)
Steam Vent (Top)
60-9/16" (1538mm)
Water Drain
(Side Back)
T
reated Water
I
ntake (Bottom)
Untreated Water
I
ntake (Bottom)
Electrical Connection
(
Bottom)
30" (761mm)
4-3/4" (120mm)
2
-3/16" (56mm)
(290mm)
6-3/8" (161mm)
41-15/16" (1064mm)
43-7/8" (1114mm)
2
" (50mm)
49-1/8" (1247mm)
15-7/8"
(403mm)
14-3/16"
(360mm)
35-3/16" (893mm)
27-11/16"
(702mm)
7-9/16"
(192mm)
Decalcification
P
ort
11-7/16"
D I M E N SI O N S : H x W x D
EXTERIOR:
35-3/16" x 43-7/8" x 34-1/16" (893mm x 1114mm x 864mm)
EXTERIOR WITH RETRACTABLE DOOR:
35-3/16" x 47-7/8" x 34-1/16" (893mm x 1216mm x 864mm)
INTERIOR:
17-3/4" x 23-1/2" x 21-1/16" (450mm x 597mm x 535mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R EM E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q U I R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R EQ U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements (untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 5
6•10ESi SPECIFICATIONS
®
COMBITHERM
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Six (6) Four (4)
GN 1/1: 530 x 325 x 65mm Six (6) Four (4)
HALF-SIZE SHEET PANS:* 18" x 13" x 1" Six (6) Five (5)
ON WIRE SHELVES ONLY
72 lb (33 kg) MAXIMUM
VOLUME MAXIMUM
: 45 QUARTS (57 LITERS)
W E I G H T
NET 343 lb (156 kg)
SHIP 467 lb (212 kg)
CRATE 40" X 48" X 40" EST.
DIMENSIONS: (1016 x 1219 x 1016mm)
E L E C T RI C A L 6 1 0 E S i 6 1 0 E S i / s k
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
at 208 1* 50/60 2 Wire plus ground 41.0 8.5 43.3 9.0
at 240 AWG 6 47.0 11.2 48.0 11.7
at 208 3 50/60 3 Wire plus ground 23.3/ph 8.4 25.0/ph 9.0
at 240 AWG 8 27.0/ph 11.2 28.2/ph 11.7
at 380 3 50/60 4 Wire plus ground 13.0/ph 8.5 14.0/ph 9.0
at 415 AWG 12 15.6/ph 11.2 16.3/ph 11.7
at 440 3* 50/60 3 Wire plus ground 20.0/ph 15.4 21.0/ph 15.9
at 480 AWG 8 22.0/ph 18.4 23.0/ph 18.9
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
208-240
380-415
440-480
31-3/8" (796mm)
3
4-1/16" (864mm)
17-15/16"
(456mm)
7-9/16"
(191mm)
WATER
DRAIN
33-1/8" (840mm)
4-15/16"
(125mm)
Steam Vent (Top)
60-9/16" (1538mm)
Water Drain
(Side Back)
Treated Water
Intake (Bottom)
Untreated Water
I
ntake (Bottom)
Electrical Connection
(
Bottom)
30" (761mm)
4-3/4" (120mm)
2-3/16" (56mm)
11-7/16"
(290mm)
6-3/8" (161mm)
41-15/16" (1064mm)
43-7/8" (1114mm)
2" (50mm)
49-1/8" (1247mm)
15-7/8"
(403mm)
14-3/16"
(360mm)
35-3/16" (893mm)
27-11/16"
(702mm)
7-9/16"
(192mm)
L
ow Pressure
Valve (Top)
D I M E N SI O N S : H x W x D
EXTERIOR:
35-3/16" x 43-7/8" x 34-1/16" (893mm x 1114mm x 864mm)
EXTERIOR WITH RETRACTABLE DOOR:
35-3/16" x 47-7/8" x 34-1/16" (893mm x 1216mm x 864mm)
INTERIOR:
17-3/4" x 23-1/2" x 21-1/16" (450mm x 597mm x 535mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R EM E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q U I R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R EQ U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 6
®
COMBITHERM
6•10ESiN SPECIFICATIONS
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Six (6) Four (4)
GN 1/1: 530 x 325 x 65mm Six (6) Four (4)
HALF-SIZE PANS: 10" x 12" x 2-1/2" Twelve (12) Eleven (11)
GN 1/2: 265 x 325 x 65mm Twelve (12) Eleven (11)
HALF-SIZE SHEET PANS:* 18" x 13" x 1" Six (6) Five (5)
ON WIRE SHELVES ONLY
72 lb (33 kg) MAXIMUM
VOLUME MAXIMUM
: 45 QUARTS (57 LITERS)
W E I G H T
NET 348 lb (158 kg)
SHIP 472 lb (214 kg)
CRATE 40" X 37" X 40" EST.
DIMENSIONS: (1016 x 940 x 1016mm)
E L E C T RI C A L 6 1 0 E S i N 6 1 0E S i N / s k
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
at 208 1* 50/60 2 Wire plus ground 41.0 8.5 43.3 9.0
at 240 AWG 6 47.0 11.2 48.0 11.7
at 208 3 50/60 3 Wire plus ground 23.3/ph 8.4 25.0/ph 9.0
at 240 AWG 8 27.0/ph 11.2 28.2/ph 11.7
at 380 3 50/60 4 Wire plus ground 13.0/ph 8.5 14.0/ph 9.0
at 415 AWG 12 15.6/ph 11.2 16.3/ph 11.7
at 440 3* 50/60 3 Wire plus ground 20.0/ph 15.4 21.0/ph 15.9
at 480 AWG 8 22.0/ph 18.4 23.0/ph 18.9
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
208-240
380-415
440-480
D I M E N SI O N S : H x W x D
EXTERIOR:
35-3/16" x 35-13/16" x 35-9/16" (893mm x 909mm x 903mm)
EXTERIOR WITH RETRACTABLE DOOR:
35-3/16" x 39-13/16" x 35-9/16" (893mm x 1011mm x 903mm)
INTERIOR:
17-3/4" x 13-1/4" x 26-1/4" (450mm x 387mm x 665mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R EM E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q U I R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R EQ U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 7
®
COMBITHERM
10•10E
S
SPECIFICATIONS
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Ten (10)
GN 1/1: 530 x 325 x 65mm Ten (10)
HALF-SIZE SHEET PANS:* 18" x 13" x 1" Ten (10)
ON WIRE SHELVES ONLY
120 lb (54 kg) MAXIMUM
VOLUME MAXIMUM
: 75 QUARTS (95 LITERS)
W E I G H T
NET 404 lb (183 kg)
SHIP 528 lb (239 kg)
CRATE 49" X 47" X 37" EST.
DIMENSIONS: (1245 x 1194 x 940mm)
E L E C T RI C A L
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW
at 208 1* 50/60 2 Wire plus ground 67.0 13.9
at 240 AWG 3 77.0 18.4
at 208 3 50/60 3 Wire plus ground 38.5/ph 13.8
at 240 AWG 6 44.0/ph 18.3
at 380 3 50/60 4 Wire plus ground 21.5/ph 14.2
at 415 AWG 10 25.6/ph 18.4
at 440 3* 50/60 3 Wire plus ground 20.0/ph 15.4
at 480 AWG 8 22.0/ph 18.4
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
208-240
380-415
440-480
33-1/16" (840mm) 4-15/16"
(125mm)
41-1/2" (1053mm)
33-15/16" (861mm)
7-9/16" (192mm)
60-9/16" (1538mm)
Water Drain
(Back Side)
30" (761mm)
4-3/4" (120mm)
3-3/16" (80mm)
11-7/16"
(290mm)
14-3/16"
(360mm)
15-7/8"
(403mm)
2" (50mm)
46-7/8" (1190mm)
4
3-7/8" (1114mm)
31-3/8" (796mm)
34-1/16" (865mm)
17-15/16"
(456mm)
7-9/16"
(191mm)
Water Drain
6-1/4" (158mm)
41-15/16" (1064mm)
Steam Vent (Top)
Decalcification
Port
Electrical Connection (Bottom)
T
reated Water
Intake (Bottom)
Untreated Water
Intake (Bottom)
D I M E N SI O N S : H x W x D
EXTERIOR:
41-1/2" x 43-7/8" x 34-1/16" (1053mm x 1114mm x 865mm)
EXTERIOR WITH RETRACTABLE DOOR:
41-1/2" x 47-7/8" x 34-1/16" (1053mm x 1216mm x 865mm)
INTERIOR:
27" x 23-1/2" x 21-1/16" (685mm x 597mm x 535mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R EM E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q U I R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R EQ U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 8
®
COMBITHERM
10•10ESi SPECIFICATIONS
33-1/16" (840mm) 4-15/16"
(125mm)
41-1/2" (1053mm)
33-15/16" (861mm)
7-9/16" (192mm)
60-9/16" (1538mm)
Water Drain
(Back Side)
30" (761mm)
4-3/4" (120mm)
2-3/16" (56mm)
11-7/16"
(290mm)
14-3/16"
(360mm)
15-7/8"
(403mm)
Electrical Connection (Bottom)
2" (50mm)
46-7/8" (1190mm)
4
3-7/8" (1114mm)
3
1-3/8" (796mm)
34-1/16" (865mm)
17-15/16"
(
456mm)
7-9/16"
(
191mm)
Water Drain
6-1/4" (158mm)
4
1-15/16" (1064mm)
T
reated Water
Intake (Bottom)
U
ntreated Water
Intake (Bottom)
Steam Vent (Top)
Low Pressure
Valve (Top)
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Ten (10) Eight (8)
GN 1/1: 530 x 325 x 65mm Ten (10) Eight (8)
HALF-SIZE SHEET PANS:* 18" x 13" x 1" Ten (10) Nine (9)
ON WIRE SHELVES ONLY
120 lb (54 kg) MAXIMUM
VOLUME MAXIMUM
: 75 QUARTS (95 LITERS)
W E I G H T
NET 377 lb (171 kg)
SHIP 501 lb (227 kg)
CRATE 49" X 47" X 37" EST.
DIMENSIONS: (1245 x 1194 x 940mm)
E L E C T RI C A L 1 0 1 0 E S i 1 0 1 0 E S i / s k
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
at 208 1* 50/60 2 Wire plus ground 67.0 13.9 69.2 14.4
at 240 AWG 3 77.0 18.4 79.0 18.9
at 208 3 50/60 3 Wire plus ground 38.6/ph 13.9 40.0/ph 14.4
at 240 AWG 6 44.3/ph 18.4 45.5/ph 18.9
at 380 3 50/60 4 Wire plus ground 21.1/ph 13.9 22.0/ph 14.4
at 415 AWG 10 25.6/ph 18.4 26.3/ph 18.9
at 440 3* 50/60 3 Wire plus ground 20.0/ph 15.4 21.0/ph 15.9
at 480 AWG 8 22.0/ph 18.4 23.0/ph 18.9
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
208-240
380-415
440-480
D I M E N SI O N S : H x W x D
EXTERIOR:
41-1/2" x 43-7/8" x 34-1/16" (1053mm x 1114mm x 865mm)
EXTERIOR WITH RETRACTABLE DOOR:
41-1/2" x 47-7/8" x 34-1/16" (1053mm x 1216mm x 865mm)
INTERIOR:
27" x 23-1/2" x 21-1/16" (685mm x 597mm x 535mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R EM E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q UI R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 9
®
COMBITHERM
10•10E
S
i
N
SPECIFICATIONS
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Ten (10) Eight (8)
GN 1/1: 530 x 325 x 65mm Ten (10) Eight (8)
HALF-SIZE SHEET PANS:* 18" x 13" x 1" Ten (10) Nine (9)
ON WIRE SHELVES ONLY
120 lb (54 kg) MAXIMUM
VOLUME MAXIMUM
: 75 QUARTS (95 LITERS)
W E I G H T
NET 385 lb EST. (175 kg) EST.
SHIP 500 lb EST. (227 kg) EST.
CRATE 49" X 44" X 40" EST.
DIMENSIONS: (1245 x 1118 x 1016mm)
E L E C T RI C A L 1 0 1 0 E S i N 1 0 1 0 E S i N / s k
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
at 208 1* 50/60 2 Wire plus ground 67.0 13.9 69.2 14.4
at 240 AWG 3 77.0 18.4 79.0 18.9
at 208 3 50/60 3 Wire plus ground 38.6/ph 13.9 40.0/ph 14.4
at 240 AWG 6 44.3/ph 18.4 45.5/ph 18.9
at 380 3 50/60 4 Wire plus ground 21.1/ph 13.9 22.0/ph 14.4
at 415 AWG 10 25.6/ph 18.4 26.3/ph 18.9
at 440 3* 50/60 3 Wire plus ground 20.0/ph 15.4 21.0/ph 15.9
at 480 AWG 8 22.0/ph 18.4 23.0/ph 18.9
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
208-240
380-415
440-480
19-1/2"
(495mm)
12-5/16"
(312mm)
9-9/16"
(242mm)
35-7/8" (910mm)
3
3-7/8" (860mm)
3
3" (837mm)
2" (50mm)
35-11/16" (905mm)
25"
(635mm)
19-9/16"
(
496mm)
7
-9/16"
(191mm)
5
" (126mm)
Water Drain
(Side Back)
S
team
Vent
(Top)
2
1-15/16"
(557mm)
41-1/16" (1043mm)
4-3/4" (120mm)
2
-3/16" (55mm)
E
lectrical Connection
(Bottom)
54-1/8" (1375mm)
7-9/16" (192mm)
33-7/8"
(859mm)
41-3/8" (1050mm)
Treated Water
Intake (Bottom)
Untreated Water Intake
(Bottom)
WATER
DRAIN
6-3/8" (161mm)
L
ow Pressure
Valve
D I M E N SI O N S : H x W x D
EXTERIOR:
41-3/8" x 35-7/8" x 35-11/16" (1050mm x 910mm x 905mm)
EXTERIOR WITH RETRACTABLE DOOR:
41-3/8" x 39-7/8" x 35-11/16" (1050mm x 1012mm x 905mm)
INTERIOR:
27" x 13-1/4" x 26-1/4" (685mm x 387mm x 665mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R EM E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q U I R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R EQ U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 10
®
COMBITHERM
7•14ES SPECIFICATIONS
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Fourteen (14)
GN 1/1: 530 x 325 x 65mm Fourteen (14)
GN 2/1: 650 x 530 x 65mm Seven (7)
FULL-SIZE SHEET PANS:* 18" x 26" x 1" Seven (7)
ON WIRE SHELVES ONLY
168 lb (76 kg) MAXIMUM
VOLUME MAXIMUM
: 105 QUARTS (133 LITERS)
W E I G H T
NET 416 lb (189 kg)
SHIP 540 lb (245 kg)
CRATE 52" X 50" X 46" EST.
DIMENSIONS: (1321 x 1270 x 1168mm)
E L E C T R I C A L
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW
at 208 1* 50/60 2 Wire plus ground 67.0 13.9
at 240 AWG 3 77.0 18.4
at 208 3 50/60 3 Wire plus ground 38.5/ph 13.8
at 240 AWG 6 44.0/ph 18.3
at 380 3 50/60 4 Wire plus ground 21.5/ph 14.2
at 415 AWG 10 25.6/ph 18.4
at 440 3* 50/60 3 Wire plus ground 20.0/ph 15.4
at 480 AWG 8 22.0/ph 18.4
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
208-240
380-415
440-480
TOP VIEW
FRONT VIEW SIDE VIEW
Helvetica
Light Condensed
8 pt
Decalcification
P
ort
12-3/4"
(323mm)
15-1/2"
(393mm)
22-3/8" (568mm)
4-11/16" (120mm)
2
-5/16" (58mm)
D I M E N SI O N S : H x W x D
EXTERIOR:
34-1/4" x 43-7/8" x 42-13/16" (869mm x 1114mm x 1087mm)
EXTERIOR WITH RETRACTABLE DOOR:
34-1/4" x 47-7/8" x 42-13/16" (869mm x 1216mm x 1087mm)
INTERIOR:
20-5/16" x 23-1/2" x 28-7/16" (515mm x 596mm x 722mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R EM E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q UI R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R EQ U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 11
®
COMBITHERM
7•14E
S
i SPECIFICATIONS
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Fourteen (14) Twelve (12)
GN 1/1: 530 x 325 x 65mm Fourteen (14) Twelve (12)
GN 2/1: 650 x 530 x 65mm Seven (7) Five (5)
FULL-SIZE SHEET PANS:* 18" x 26" x 1" Seven (7) Six (6)
ON WIRE SHELVES ONLY
168 lb (76 kg) MAXIMUM
VOLUME MAXIMUM
: 105 QUARTS (133 LITERS)
W E I G H T
NET 436 lb (198 kg)
SHIP 560 lb (254 kg)
CRATE 42" X 50" X 46" EST.
DIMENSIONS: (1067 x 1270 x 1168mm)
E L E C T RI C A L 7 1 4 E S i 7 1 4 E S i / s k
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
at 208 1* 50/60 2 Wire plus ground 67.0 13.9 69.2 14.4
at 240 AWG 3 77.0 18.4 79.0 18.9
at 208 3 50/60 3 Wire plus ground 38.6/ph 13.9 40.0/ph 14.4
at 240 AWG 6 44.3/ph 18.4 45.5/ph 18.9
at 380 3 50/60 4 Wire plus ground 21.1/ph 13.9 22.0/ph 14.4
at 415 AWG 10 25.6/ph 18.4 26.3/ph 18.9
at 440 3* 50/60 3 Wire plus ground 20.0/ph 15.4 21.0/ph 15.9
at 480 AWG 8 22.0/ph 18.4 23.0/ph 18.9
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
208-240
380-415
440-480
TOP VIEW
FRONT VIEW SIDE VIEW
Helvetica
Light Condensed
8 pt
Low Pressure Valve
12-3/4"
(323mm)
15-1/2"
(393mm)
22-3/8" (568mm)
4-11/16" (120mm)
2
-5/16" (58mm)
D I M E N SI O N S : H x W x D
EXTERIOR:
34-1/4" x 43-7/8" x 42-13/16" (869mm x 1114mm x 1087mm)
EXTERIOR WITH RETRACTABLE DOOR:
34-1/4" x 47-7/8" x 42-13/16" (869mm x 1216mm x 1087mm)
INTERIOR:
20-5/16" x 23-1/2" x 28-7/16" (515mm x 596mm x 722mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R EM E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q U I R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R EQ U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 12
®
COMBITHERM
10•18ES SPECIFICATIONS
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Twenty (20)
GN 1/1: 530 x 325 x 65mm Twenty (20)
GN 2/1: 650 x 530 x 65mm Ten (10)
FULL-SIZE SHEET PANS:* 18" x 26" x 1" Ten (10)
ON WIRE SHELVES ONLY
240 lb (109 kg) MAXIMUM
VOLUME MAXIMUM
: 150 QUARTS (190 LITERS)
W E I G H T
NET 522 lb (237 kg)
SHIP 646 lb (293 kg)
CRATE 46" X 51" X 46" EST.
DIMENSIONS: (1168 x 1295 x 1168mm)
E L E C T R I C A L
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW
at 208 3 50/60 3 Wire plus ground 61.3/ph 22.0
at 240 AWG 2 70.0/ph 29.2
at 380 3 50/60 4 Wire plus ground 33.5/ph 22.0
at 415 AWG 6 40.7/ph 29.2
at 440 3* 50/60 3 Wire plus ground 36.0/ph 27.2
at 480 AWG 6 43.5/ph 36.1
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
380-415
440-480
Decalcification
Port
30"
(760mm)
22-3/8"
(568mm)
15-1/2"
(393mm)
12-3/4"
(323mm)
E
lectrical Connection
(Bottom)
2" (50mm)
4
6-7/8" (1190mm)
43-7/8"
(
1114mm)
41-15/16"
(
1064mm)
4
0-1/8"
(
1019mm)
25-5/8"
(
650mm)
8
-11/16"
(219mm)
6-1/4" (158mm)
W
ater Drain
(
Bottom)
4
2-13/16"
(1087mm)
3
3-1/8"
(
840mm)
4
-15/16"
(
125mm)
S
team
V
ents
(Top)
W
ater Drain
(
Side Back)
69-3/8" (1761mm)
7-9/16" (192mm)
40-7/16" (1026mm)
32-7/8"
(834mm)
T
reated Water
I
ntake (Bottom)
Untreated Water
I
ntake (Bottom)
4
-11/16" (120mm)
2-5/16" (58mm)
D I M E N SI O N S : H x W x D
EXTERIOR:
40-7/16" x 43-7/8" x 42-13/16" (1026mm x 1114mm x 1087mm)
EXTERIOR WITH RETRACTABLE DOOR:
40-7/16" x 47-7/8" x 42-13/16" (1026mm x 1216mm x 1087mm)
INTERIOR:
30-3/4" x 23-1/2" x 28-7/16" (781mm x 596mm x 722mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R E M E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q UI R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 13
10•18ESi SPECIFICATIONS
®
COMBITHERM
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Twenty (20) Eighteen (18)
GN 1/1: 530 x 325 x 65mm Twenty (20) Eighteen (18)
GN 2/1: 650 x 530 x 65mm Ten (10) Eight (8)
FULL-SIZE SHEET PANS:* 18" x 26" x 1" Ten (10) Nine (9)
ON WIRE SHELVES ONLY
240 lb (109 kg) MAXIMUM
VOLUME MAXIMUM
: 150 QUARTS (190 LITERS)
W E I G H T
NET 520 lb (236 kg)
SHIP 640 lb (290 kg)
CRATE 46" X 51" X 46" EST.
DIMENSIONS: (1168 x 1295 x 1168mm)
E L E C T RI C A L 1 0 1 8 E S i 1 0 1 8 E S i / s k
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW AMPS kW
at 208 3 50/60 3 Wire plus ground 61.1/ph 22.0 62.5/ph 22.5
at 240 AWG 2 70.3/ph 29.2 71.5/ph 29.7
at 380 3 50/60 4 Wire plus ground 33.5/ph 22.0 34.2/ph 22.5
at 415 AWG 8 40.7/ph 29.2 41.4/ph 29.7
at 440 3* 50/60 3 Wire plus ground 35.7/ph 27.2 36.4/ph 27.7
at 480 AWG 8 43.5/ph 36.1 44.0/ph 36.6
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
380-415
440-480
30"
(760mm)
4-11/16" (120mm)
2-5/16" (58mm)
22-3/8"
(568mm)
15-1/2"
(393mm)
12-3/4"
(323mm)
Electrical Connection
(
Bottom)
2" (50mm)
46-7/8" (1190mm)
4
3-7/8"
(1114mm)
41-15/16"
(1064mm)
40-1/8"
(
1019mm)
25-5/8"
(650mm)
8-11/16"
(219mm)
6-1/4" (158mm)
Water Drain
(
Bottom)
42-13/16"
(1087mm)
33-1/8"
(840mm)
4-15/16"
(125mm)
Steam
Vents
(Top)
Water Drain
(Side Back)
69-3/8" (1761mm)
7-9/16" (192mm)
40-7/16" (1026mm)
32-7/8"
(834mm)
Treated Water
I
ntake (Bottom)
Untreated Water
Intake (Bottom)
L
ow Pressure
Valve (Top)
D I M E N SI O N S : H x W x D
EXTERIOR:
40-7/16" x 43-7/8" x 42-13/16" (1026mm x 1114mm x 1087mm)
EXTERIOR WITH RETRACTABLE DOOR:
40-7/16" x 47-7/8" x 42-13/16" (1026mm x 1216mm x 1087mm)
INTERIOR:
30-3/4" x 23-1/2" x 28-7/16" (781mm x 596mm x 722mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R EM E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q U I R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
COUNTER
-TOP INSTALLATIONS MUST MAINTAIN 4" (102mm) MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R EQ U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 14
12•20ES SPECIFICATIONS
®
COMBITHERM
46-3/4"
(1186mm)
44-3/4"
(1136mm)
40-15/16"
(1039mm)
1-13/16"
(46mm)
48"
(1218mm)
45-5/16"
(1151mm)
33-1/2"
(851mm)
2-1/16" (52mm)
Water Drain
(
Bottom)
51-15/16"
(1319mm)
2" (50mm)
76-15/16" (1954mm)
8-15/16"
(226mm)
7-11/16" (195mm)
46-1/2"
(1155mm)
54-3/8" (1381mm)
13-1/16" (331mm)
15-13/16" (401mm)
22-11/16"
(576mm)
11-7/8"
(302mm)
W
ater Drain
(Side Back)
Steam
V
ents
(Top)
4-1/4"
(
106mm)
T
reated Water
Intake (Bottom)
Untreated Water
Intake
(
Bottom)
E
lectrical
Connection (Bottom)
6-11/16"
(169mm)
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Twenty-four (24)
GN 1/1: 530 x 325 x 65mm Twenty-four (24)
GN 2/1: 650 x 530 x 65mm Twelve (12)
FULL-SIZE SHEET PANS:* 18" x 26" x 1" Twelve (12)
ON WIRE SHELVES ONLY
288 lb (131 kg) MAXIMUM
VOLUME MAXIMUM
: 180 QUARTS (228 LITERS)
W E I G H T
NET 747 lb (339 kg)
SHIP 1070 lb (485 kg)
CRATE 61" X 58" X 53"
DIMENSIONS: (1549 x 1473 x 1346mm)
E L E C T R I C A L
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW
at 208 3 50/60 3 Wire plus ground 75.6/ph 27.2
at 240 AWG 2 87.0/ph 36.1
at 380 3 50/60 4 Wire plus ground 41.4/ph 27.2
at 415 AWG 6 50.0/ph 35.7
at 440 3* 50/60 3 Wire plus ground 36.0/ph 27.2
at 480 AWG 6 43.5/ph 36.1
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
380-415
440-480
D I M E N SI O N S : H x W x D
EXTERIOR:
54-3/8" x 46-3/4" x 48" (1381mm x 1186mm x 1218mm)
EXTERIOR WITH RETRACTABLE DOOR:
54-3/8" x 50-3/4" x 48" (1381mm x 1288mm x 1218mm)
INTERIOR:
38-11/16" x 26-1/4" x 32-11/16" (983mm x 667mm x 830mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R E M E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q UI R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
WAT E R R EQ U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements
(untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 15
20•20ES SPECIFICATIONS
®
COMBITHERM
40-15/16"
(1039mm)
1-13/16"
(46mm)
46-3/4"
(1186mm)
44-3/4"
(1136mm)
4-3/4"
(120mm)
2" (50mm)
51-15/16" (1319mm)
W
ater Drain
(Side Back)
Steam
Vents
(Top)
76-15/16" (1954mm)
8-15/16" (226mm)
67-3/8" (1710mm)
76-1/4" (1936mm)
12-15/16"
(326mm)
24-7/8"
(629mm)
27-5/8"
(699mm)
5
" (127mm)
11-7/8"
(302mm)
Treated Water
Intake (Bottom)
Intake (Bottom)
Electrical
Connection (Bottom)
Untreated Water
45-5/16"
(
1151mm)
48"
(1218mm)
Water Drain
(Bottom)
7-11/16" (195mm)
2-1/16" (52mm)
33-1/2"
(851mm)
C A PA C I T Y
FULL-SIZE PANS: 20" x 12" x 2-1/2" Forty (40)
GN 1/1: 530 x 325 x 65mm Forty (40)
GN 2/1: 650 x 530 x 65mm Twenty (20)
FULL-SIZE SHEET PANS:* 18" x 26" x 1" Twenty (20)
ON WIRE SHELVES ONLY
480 lb (218 kg) MAXIMUM
VOLUME MAXIMUM
: 300 QUARTS (380 LITERS)
W E I G H T
NET 958 lb EST. (435 kg) EST.
SHIP 1340 lb (608 kg)
CRATE 83" X 54" X 53"
DIMENSIONS: (2108 x 1372 x 1346mm)
E L E C T RI C A L
VOLTAGE PHASE CYCLE/HZ AWG AMPS kW
at 208 3 50/60 3 Wire plus ground 151.2/ph 54.4
at 240 AWG 4 173.4/ph 72.2
at 380 3 50/60 4 Wire plus ground 83.0/ph 54.4
at 415 AWG 2 101.0/ph 72.2
at 440 3* 50/60 3 Wire plus ground 71.5/ph 54.4
at 480 AWG 2 87.0/ph 72.2
* ELECTRICAL SERVICE CHARGE APPLIES
208-240
380-415
440-480
D I M E N SI O N S : H x W x D
EXTERIOR:
76-1/4" x 46-3/4" x 48" (1936mm x 1186mm x 1218mm)
EXTERIOR WITH RETRACTABLE DOOR:
76-1/4" x 50-3/4" x 48" (1936mm x 1288mm x 1218mm)
INTERIOR:
60-1/4" x 26-1/4" x 32-11/16" (1530mm x 667mm x 830mm)
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I ON R E Q U I R E M E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R AN C E R E Q UI R E M E N T S
LEFT : 6" (152mm) PLUS SERVICE ACCESS: 18" (457mm) RECOMMENDED
20" (508mm) F RO M H EAT P R OD U C IN G E QU I P M E N T
RIGH T
: 4" (102mm) TOP: 20" (508mm) FOR AIR MOVEMENT
BACK
: 4" (102mm) BOTT O M: 5-1/8" (130mm) FOR LEGS
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET: 3/4" NPT*
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q UA L I T Y M I N I M U M S TA N D AR D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant Inlet Water Requirements (untreated water)
Free Chlorine Less than 0.1 ppm (mg/L)
Hardness Less than 3 gpg (52 ppm)
Chloride Less than 30 ppm (mg/L)
pH 7.0 to 8.5
Alkalinity Less than 50 ppm (mg/L)
Silica Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds) Less than 60 ppm
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 16
®
COMBITHERM
®
LOCATION SITE & INSTALLATION REQUIREMENTS
THE OVEN MUST REMAIN ON
THE PALLET WHILE BEING
MOVED TO THE INSTALLATION
SITE BY FORK LIFT OR
PALLET LIFT TRUCK.
N O T E : Note dimensions required for doorways
and aisles for access of the oven and
pallet to the installation site. Transport
the oven in an upright and level position
only. Do not tilt the oven.
®
I N S TA L L AT I O N C O D E S & S TA N D A R D S
The following codes and standards are required for installation of this oven:
AIR SUPPLY, ELECTRICAL CONNECTIONS, WATER CONNECTIONS, AND
WASTE WATER DISCHARGE.
N
O
T
E
Where automatically operated appliances are vented through a ventilating hood or exhaust
system equipped with a damper or with a power means of exhaust, provisions shall be made
to allow the equipment to operate only when the damper is open to a position to properly
vent the appliance and when the power means of exhaust is in operation.
IN ACCORDANCE WITH NFPA 54 COMMONWEALTH OF MASSACHUSETTS ONLY.
D A N G E R
IMPROPER INSTALLATION,
A
LTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
D A N G E R
AVERTISSEMENT : UNE INSTALLATION,
UN AJUSTEMENT, UNE ALTÉRATION,
U
N SERVICE OU UN ENTRETIEN NON
C
ONFORME AUX NORMES PEUT CAUSER
DES DOMMAGES À LA PROPRIÉTÉ, DES
BLESSURES OU LA MORT.
LIRE ATTENTIVEMENT LES DIRECTIVES
D’OPÉRATION ET D’ENTRETIEN AVANT
DE FAIRE L’INSTALLATION, OU
L’ENTRETIEN DE CET ÉQUIPEMENT.
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 17
®
COMBITHERM
®
VENTILATION REQUIREMENTS
A steam ventilation hood is mandatory for the
operation of the oven. The ventilation hood must
be installed in accordance with local building
c
odes for the steam exhaust and must protrude
12-inches to 20-inches (300 to 500mm) over the
front side of the oven. A grease filter must be
located in the protruding area of the hood. Grease
filters should be thoroughly cleaned on a regular
basis following manufacturer's instruction.
Ventilation hoods must ensure an adequate
amount of incoming air during operation and
must be operated whenever the combination
oven/steamer is used in order to avoid the
accumulation of condensation in the hood area.
POSITIONING ON SITE
Lift the oven from the pallet with a fork lift or
pallet lift truck positioned at the front of the oven.
For damage protection, the use of two wooden
boards, placed between the bottom of the oven
and the lifting forks, is strongly recommended. To
avoid damage, position the lift forks to the left of
the condenser and right of the right leg as
indicated in the diagram at right.
Stand the oven in a level position. Use the
adjustable feet to overcome an uneven floor and
ensure that the unit is level.
It is strongly recommended that table top models
be mounted on a factory supplied stand or a stand
that is stable, open, level, and non-combustible.
Recommended height is 23-inches (584mm).
Adjust the height of floor models for smooth
access of the trolley or cart. When positioning the
oven, observe the minimum space allocation
requirements shown.
To insure proper operation, the installation of this
oven must be completed by qualified technicians
in accordance with the instructions provided in
this manual. Failure to follow the instructions
provided may result in damage to the oven,
building, or cause personal injury to personnel.
LOCATION SITE & INSTALLATION REQUIREMENTS
NOTE: To avoid equipment damage, observe
attention label on oven for area to avoid
with lifting fork.
MINIMUM CLEARANCE REQUIREMENTS
LEFT SIDE 6" (152mm) MINIMUM
18" (457mm) SERVICE ACCESS RECOMMENDED
20" (508mm) FROM HEAT PRODUCING EQUIPMENT
RIGHT SIDE 4" (102mm)
BACK 4" (102mm) FOR PLUMBING
TOP 20" (508mm) FOR AIR MOVEMENT
NOTE: Additional clearance is needed for service
access. A minimum distance of 18-inches is
strongly recommended. If adequate service
clearance is not provided, it will be necessary to
disconnect the gas, water, and drain to move the
oven with a fork lift for service access. Charges in
connection with inadequate service access is not
covered under warranty.
C A U T I O N
TO PREVENT PERSONAL INJURY,
U
SE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
ELECTRIC COMBITHERM INSTALLATION MANUAL #MN-28677
PG. 18
®
COMBITHERM
®
LOCATION SITE & INSTALLATION REQUIREMENTS
POSITIONING REQUIREMENTS
In order to ensure proper ventilation, a
minimum distance of at least 6-inches (152mm)
must be kept from the control panels side (left)
of the oven and any adjoining surfaces.
NOTE: Additional clearance is needed for
service access. A minimum distance of 18-inches
is strongly recommended. If adequate service
clearance is not provided, it will be necessary to
disconnect the gas, water, and drain to move the
oven with a fork lift for service access. Charges
in connection with inadequate service access is
not covered under warranty.
Allow a minimum of 4-inches (102mm) from the
right side of the oven to allow the door to open
to at least a 90° angle. Fully opened, the door
will extend up to a 225° angle If the oven is
furnished with the retractable door option,
allow a minimum clearance of
6-1/2 inches (165mm).
Allow a minimum clearance of 4-inches
(102mm) from the back of the oven for
plumbing connections.
Allow a 20-inch (500mm) clearance at the top of
the oven for free air movement and for the
steam vent(s) located at the top.
Do not install the oven adjacent to heat
producing equipment such as fryers, broilers,
etc. Heat from such appliances may cause
damage to the controls of the Combitherm.
Minimum clearance recommended:
20-inches (500mm)
Place the Combitherm oven on a stable,
non-combustible level horizontal surface. For
countertop models, the oven
stand must be
level. In
addition, the
overall height of the oven should be positioned so
the operating controls and shelves may be
conveniently reached from the front. Level the
oven front-to-back and side-to-side by means of
the adjustable legs.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Alto-Shaam 10.18 User manual

Category
Ovens
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI