La Marzocco GS/3 Installation Manualline

  • Hello! I've reviewed the installation guide for the La Marzocco gs3 and gs3 MP espresso machines. This document contains important information regarding dimensions, water connection, drainage requirements, and recommended water quality. I'm ready to answer your questions about the installation process and specifications of this machine.
  • What is the recommended water flow rate?
    What should be the dynamic water pressure?
    What is the maximum drain distance?
    What is the recommended slope for drain?
height 355mm (382mm for MP)
width 400mm
depth 530mm
specifications for plumb-in
disregard if using the internal water reservoir
water flow rate 8 litres per minute
dynamic water pressure † 45PSI
min.pipe size diameter* 3/4 “*
water connection* 3/4 ”male comp
water quality water kits are provided
with your machine
See water specifications
max. dist* 1.5m
drain slope* ‡ 30mm per metre
counter hole diameter 65mm
* suggested | † regulate as needed | ‡ this machine must be installed in accordance with the applicable federal, state and
local plumbing codes
shipping weight 46kg
operating weight 34.5kg
voltage/phase 220-240V single phase
standard watts 2100
waterdimensions
drainage
weights
power
gs3 installation guideline
HOME
La Marzocco recommends that your
filtration system produces water
with the following properties:
1. centre line of the machine
2. position of the power cord
3. suggested diameter of counter hole: 65mm
4. position of the drain tube
5. position of the water inlet hose
6. width of legs per model
machine leg location
specifications for plumb-in.
disregard if using the internal
water reservoir.
1. 3/8” cold water supply
2. water filter required if plumbed
(not provided)
see water specifications below.
3. 3/8” BSPP cold water supply
line suggested max. dist. from
water supply 203mm
4. 3/4” flexible drainline
(min. 3cm per metre slope)
5. sink drain above p-trap
6. 220-240V, 10amp electrical supply
to grinder
7. 220 - 240V, electrical supply to
espresso machine (10 Amp plug included)
T.D.S
Total Hardness
Total Iron
Free Chlorine
Total Chlorine
90 -150ppm
70-100ppm
0-0.02ppm
0-0.05ppm
0-0.1ppm
pH
Alkalinity
Chloride
Line Pressure
Flow Rate
6.5 - 8
40-80ppm
0-50ppm
45-80PSI
8 litres per minute
top view
front view
water specifications
for any queries please contact the tech team at [email protected]
1
5
2
4
353mm
384mm
226mm
155mm
71mm
295mm
264mm
20mm 180mm 297mm
40.6mm
3
6
1
2
3
4
5
6
7
/