6
68-3438-50 Rev. A
01 20
© 2020 Extron Electronics — All rights reserved. www.extron.com All trademarks mentioned are the property of their respective owners.
Worldwide Headquarters: Extron USA West, 1025 E. Ball Road, Anaheim, CA 92805, 800.633.9876
DTP2 CrossPoint 82 • Setup Guide (Continued)
Command ASCII Command Response Additional Description
Video Mute
Mute output video
X@*1B VmtX@*1]
Mute the video on output X@.
Mute video on all outputs
1B Vmt1]
Mute the video on all outputs.
Mute video and sync
2B Vmt2]
Mute the video and sync on all outputs.
Unmute video and sync
0B Vmt0]
Unmute the video on all outputs.
View output mute status
B VmtX4@
1
•X4@
2
•X4@
3
] View mute status X4@ for outputs 1, 2, and loop (3).
Audio Configuration
Set audio input format
EIX!*X5*AFMT} AfmtIX!*X5*]
Set the audio format of input X! to X5*.
View audio input format
EIX!AFMT} X5*]
View the audio format of input X!.
Front Panel Lockout (Executive Modes)
Enable lock mode 1
1X Exe1]
Lock all front panel controls.
Enable lock mode 2
2X Exe2]
Lock the front panel except for input selection, logo
conguration, and volume adjustment.
Enable lock mode 3
3X Exe3]
Lock the front panel except for input selection and logos.
Enable lock mode 4
4X Exe4]
Lock the front panel except for volume adjustment.
Disable executive modes
0X Exe0]
Allow all front panel adjustments and selections.
IP Settings
Set switcher IP address
EX8&CI} Ipi
•
X8&]
Specify a new switcher IP address.
Set switcher DHCP mode
EX( DH} IdhX1)] Enable or disable DHCP (0 = default).
Set subnet mask
EX8*CS} Ips
•
X8*]
Specify a new subnet mask.
Set gateway IP address
EX8(CG} Ipg
•
X8(]
Specify a new gateway IP address.
Reboot network
E2BOOT} Boot2]
Restart network connection after IP or DHCP changes.
NOTE: IP settings do not take effect until the E2BOOT} command is executed.
Twisted Pair Protocol
Set input TP type
EIX!*X6&HDBT} HdbtIX!*X6&]
Set the DTP2/XTP type for input X! to X6&.
View input TP type
EIX!HDBT}
X6&] View the current DTP2/XTP type for input X!.
Set output TP type
EO 2*X6&HDBT} HdbtO 2*X6&]
Set the TP type for input X! to X6&.
View output TP type
EO 2 HDBT}
X6&] View the DTP2/XTP/HDBT setting X6& on output 2.
DTP Remote Power Parameters
Set input remote power
EIX!*X6^RPWR} RpwrIX!*X6^]
Set remote power on input X! to X6^.
View input remote power
EIX!RPWR}
X6^] View remote power setting on input X!.
Set output 2 remote power
EO 2*X6^RPWR} RpwrO 2*X6^]
Set remote power on output 2 to X6^.
View output 2 remote power
EOX@RPWR}
X6^]
View remote power setting on output .
KEY:
X! = Input selection Inputs 1 through 8. For the Twisted Pair Protocol commands, X! = Inputs 7 and 8 only.
X@ = Output selection 1 = Output 1 (HDMI/DVI), 2 = Output 2 (DTP2/XTP/HDBT)
X1) = Enable or disable 0 = Off or disabled, 1 = on or enabled
X4@ = Video mute status 0 = Unmuted, 1 = muted
X5* = Audio input type 0 = None (input muted), 1 = Analog aux line (5-pole captive screw), 2 = LPCM-2Ch, 3 = Multi-Ch,
4 = LPCM-2Ch Auto (AUX) (default), 5 = Multi-Ch Auto (AUX)
X6^ = DTP remote power 0 = Off (No remote power, default), 1 = DTP 12 VDC, 2 = DTP 48 VDC
X6& = TP format 0 = DTP2 format (default), 1 = XTP, 2 = HDBaseT format (supported on output only)
X8& = IP address Format nnn.nnn.nnn.nnn, 192.168.254.254 = default
X8* = Subnet mask Format nnn.nnn.nnn.nnn, 255.255.255.0 = default
X8( = Gateway address Format nnn.nnn.nnn.nnn, 0.0.0.0 = default
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the
Extron Safety and Regulatory Compliance Guide on the Extron website.