Paxton Net2 Evaluation Kit User guide

Type
User guide
Ins-30108 Net2 Evaluation Kit
20/11/2009
Quickstart guide
The evaluation kit contains the hardware required to show the layout of an operating Net2 system.
The unit is based on a Paxton power supply housing arranged as it would be in a live installation.
A hands free interface is located beneath the Net2 classic ACU.
To power the unit, remove the lid holding screw and plug the mains cable into the power supply connection. The
cable may be tied to the base if required. Close and secure the lid.
Power on the unit by means of the front switch and the power LED should illuminate. The ACU should display 5v,
12v and a ashing OK LED.
Connect your PC to the Network port and set up the ethernet connection as per the instructions on page 2.
P series reader
On/Off
Switch
Power LED
Exit button
A full range of application notes and tutorials are available to guide you through the set-up and operation of the
Net2 system. - Just click on the Documentation icon on the Net2 welcome screen for the complete list.
Documentation
AC Mains
Connection
Technical Support
Technical help is available: Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
01273 811011
Entry conrmation button
Door contact switch
Door lock LED indicator
Network
connection for a PC
Features
Hands free interface
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Paxton
Connecting to a TCP/IP interface
Install the Net2 software on the PC. Connect the unit to the PC via a Network cable.
Run the Net2 Server Conguration Utility (Start/Programs/Net2) and select TCP/IP nodes.
Click on “Detect” the MAC address of the Ethernet interface will appear in the table. You should then go to the “IP
address conguration” tab and assign the IP address.
You can set up a new IP for the interface but if this is not in the same range as the PC, the device will no longer
respond until you connect to the device with a PC that is in the same IP range.
Some rewall/virus software or other wireless hardware can block the IP detection process. Disable these and try
to detect the interface again. Please contact Technical Support if you require further advice.
*The MAC address can be found on a label in the case and starts 00-xx-xx-xx
Software conguration
Run the Net2 software.
Check that the ACU has been detected by looking in the Doors screen. The rmware in the ACU’s will be
automatically updated to the same revision as the PC. Do not make any changes to the software during this phase.
Reader 1: Settings for Reader 1 and Keypad 1 on the ACU.
Reader 2: Settings for Reader 2 and Keypad 2 on the ACU.
Alarm: Contains settings for the different types of alarm.
Codes: Valid codes can be viewed, added and removed.
(Can only be viewed when a keypad is active).
Events: Shows the events for the control unit selected.
Door name: Name the ACU.
Door open time: Set the door open time.
Unlock the Door during: Permanently unlocks the door while
this timezone is active. - Should be set to ‘At No Time’ for
normal user operation.
Name: Each reader can be named individually if required.
Reader type: Set the reader type, if applicable.
Keypad type: Set the keypad type, if applicable.
Token data format: Select the data type being used on the
system. (New formats can be created).
Reader operating mode: Set the operating mode.
Timed operating modes: A different operating mode can be
congured within a time window.
Reader action: Set the action required when access is granted.
The following screen shows the setup for an ACU. This unit only requires Reader 1 to be congured to operate.
10,000
10,000
250
64
2,000
999,999 secs
50
1
2
2
2
200
50
9 hours
2,454
http://paxton.info/720
Number of PIN’s
Access Levels
Time Zones
Individual time periods per zone
Maximum door open time
Doors per ACU
Reader ports per ACU
Readers per port
Keypads per port
ACU per data line
Data lines per PC
Data retention after total power loss
Events stored in ACU with no server connection
Minimum Requirements
Hardware
Software
Specications
Number of Cards
PC Installation
Number of Codes
Switchable 120 Ohm resistors
Reset to DHCP mode
To reset the unit, power up with
this button held down until the
‘heartbeat’ LED stops ashing. The
interface will now be fully reset and
will operate in DHCP mode.
0V12V
Green
White/Green
1
Screen or spare cores from
network cable
White/O rang e
3
Orange
4
K
R 1
red
a
e da
p
y
e 1
R l
e
ay 2 R le ay 1
Keypad 2 Reader 2
stupnI
P
ew
o r
C
A
nidocelba
c
5T g
kro
w
teN
Net2 classic
2
R
ed 12V dc
Red LED
Amber LED
Green LED
Data/D0
Clock/D1
Media Detect
0V out
Load
Data
Clock
R
c
d
V
2
1
d
e
R
D
E
L
d
e
D
E
L
r
e
b
m
A
D
E
L
n
e
e
r
G
0
D
/
a
t
a
D
1
D
/
k
c
o
l
C
t
c
e
t
e
D
a
i
d
e
M
t
u
o
V
0
d
a
o
L
a
t
a
D
k
c
o
l
C
+12V
0V
T
F
:
n
oit
ua
C
r
o
y
l
n
o
s
r
e
d
a
erc
.
dV2
1 . F t
ce
r
r
o
c
ro
noit
c
e
nn
oc
f
o
f
e
rs
r
e
d
a
e
r
V
5
d
l
o
r
e
ot
s
n
oit
c
u
rt
sn
i
PLACE SERIAL
NUMBER
LABEL HERE
http://paxton.info/107
123456
1
2
3
4 5
6
Switch Right - Resistors active
Statement of Conformity
The declaration of conformity is available on request. Contact details are provided at: http://paxton.info/596
Paxton Access Ltd hereby declares that this product is in conformity with all the essential requirements of Directive
1999/5/EC. This equipment is intended for use in all EU and EFTA countries and all other countries worldwide.
LED key
1 - 120 ohm resistors (Active when LED on)
2 - Net2 RS485 data line activity
3 - Power on
4 - Ethernet data
5 - Ethernet line connection
6 - Heartbeat (connection to Net2 server)
Appendix A - TCP/IP converter
DO NOT HARD WIRE IN RESISTORS
Appendix B - Hands free interface
12V dc
Red LED
Amber LED
Green LED
Data/D0
Clock/D1
Media Detect
Entry
0V
Access Power
Entry Confirm (opt)
12V dc
Red LED
Amber LED
Green LED
Data/D0
Clock/D1
Media Detect
Entry
0V
t
i
n
U
l
o
r
t
n
o
C
r
e
d
a
e
R
V
0
yr
t
nE/
t
i
xE
DEL
n
e
e
r
G
cd V2
1
Hands Free Interface
Green
White/Green
1
Screen or spare cores from
network cable
White/O rang e
3
Orange
4
K
R
1r
e
da
e
d
a
p
y
e
1
R le ay 2 R le ay 1
Keypad 2 Reader 2
stupnI P ewo r
C
A
n
i
d
o
c
e
l
b
a
c5
T
g
k
r
o
w
t
e
N
Net2 classic
2
R
ed 12V dc
Red LED
Amber LED
Green LED
Data/D0
Clock/D1
Media Detect
0V out
Load
Data
Clock
R
c
d
V
2
1
d
e
R
D
E
L
d
e
D
E
L
r
e
b
m
A
D
E
L
n
e
e
r
G
0
D
/
a
t
a
D
1
D
/
k
c
o
l
C
t
c
e
t
e
D
a
i
d
e
M
t
u
o
V
0
d
a
o
L
a
t
a
D
k
c
o
l
C
+12V
0V
T
F
:
n
oi
t
uaC
r
o
y
ln
o
s
r
e
d
a
e
r
c
.
d
V
2
1
.
F t
c
er
ro
c
ro
n
o
it
c
e
n
n
o
c
f
o
f
e
rs
r
e
d
a
e
r
V
5
d
l
o
r
e
o
t
s
n
o
i
t
c
u
r
t
s
n
i
PLACE SERIAL
NUMBER
LABEL HERE
http://paxton.info/107
123456
Entry conrmation button
Door contact
switch
Door lock LED
indicator
Using an entry conrmation button
Where two door readers may pick up the same hands free token, a push to make button can be used to
conrm an entry request for the specic door. Where tted, the button LED will ash for 5 seconds after the
hands free token has been recognised and must be pressed to unlock the door.
To enable the use of an entry conrmation button do the following steps:
1. Power down the interface board
2. Power up the interface board
3. Press and hold the entry conrmation button for a minumum of 3 seconds within 60 seconds of power up.
To disable the use of the button, repeat the above process.
Enrolling hand free keyfobs and keycards
Switch SW2 is used to select the xed channels used by the two keycard buttons. Select either switch 1 or 2
to set which keycard button the interface will respond to.
The unit must be power cycled if the switch position is changed, to activate the new setting.
Hands free keyfobs
These tokens should be assigned to users as per standard keyfobs. They will then operate with normal P series
readers or via the hand free interface when in range.
Hands free keycards
These should rst be assigned as per the hands free keyfob.
To enable the buttons, the keycard must rst be presented to the P series reader and then used in hands free
mode. The keycard stores the details of this interface and can then activate the door using a button.
It can also be used in normal hands free mode and also in local passive mode with other standard readers.
  • Page 1 1