  • Hello! I am an AI chatbot trained to assist you with the GE RGBS400DMWW Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
BURNER OUTPUT RATINGS: BTU/HR
Propane (LP) Gas 10” W.C.P.
BURNER
BTU
RATE
ORIFICE
SIZE (mm) COLOR MARKING
RF 12,000 0.039” (0.99) Blue/Magenta 99L
LF 9,500 0.035” (0.89) Blue/Brown 89L
RR 5,000 0.026” (0.66) Red/Yellow 66L
LR 9,500 0.035” (0.89) Blue/Brown 89L
OVEN 16,000 0.048” (1.21) Pink 0.048
To adjust your range for use with propane (LP) gas, follow
these instructions:
1. Disconnect all electrical power, at the main circuit breaker or
fuse box.
6KXWRႇWKHJDVVXSSO\WRWKHUDQJHE\FORVLQJWKHPDQXDO
VKXWRႇYDOYH
CONVERTING THE PRESSURE REGULATOR
CONVERTING THE COOKTOP BURNERS
$5HPRYHWKHWRSJUDWHVEXUQHUFDSVDQGEXUQHUKHDGV
%8VLQJDPPRU´QXWGULYHUUHPRYHWKHWRSEXUQHU
RUL¿FHV7KHVHPD\EHDFFHVVHGWKURXJKWKHEXUQHU
opening in the base.
&5HPRYHWKHSURSDQH/3RUL¿FHVIURPWKHER[SURYLGHG
7KHSURSDQH/3RUL¿FHVKDYHWKHOHWWHU³/´RQWKHWRS
To aid in identifying the proper location for the propane (LP)
RUL¿FHVGXULQJFRQYHUVLRQIURP1DWXUDO*DVWR3URSDQH
/3*DVFRORUFRGHVKDYHEHHQDGGHGWRWKHVLGHRUWRSRI
WKHRUL¿FH6HHWKHFKDUWEHORZ(DFKRUL¿FHPD\DOVRVKRZ
DVHULHVRIHQJUDYHGPDUNV,,,,,,ORFDWHGRQWKHWRS
The pressure regulator is located on the rear of the range.
6RPHPRGHOVZLOOKDYHDPHWDOVKLHOGSURWHFWLQJWKHUHJXODWRU
WKDWPXVWEHUHPRYHGIRUFRQYHUVLRQDQGUHLQVWDOOHGZKHQ
FRQYHUVLRQLVFRPSOHWH7KHSUHVVXUHUHJXODWRULVORFDWHGLQWKH
ORZHUOHIWKDQGVLGHRIWKHUDQJHDVYLHZHGIURPWKHIURQWOHIW
1. Use an adjustable wrench to unscrew the hex-nut cap from
the pressure regulator.
 &RPSOHWHO\UHPRYHWKHSURWHFWLYHSODVWLFFDSRႇWKH
threaded metal cap.
 7XUQWKHPHWDOFDSVRWKHW\SHRIJDVEHLQJFRQYHUWHGWRLV
GLVSOD\HGDQGUHSODFHWKHSURWHFWLYHSODVWLFFRYHU
4. Screw the hex-nut cap back into the regulator.
(Do not over tighten)
TOOLS REQUIRED:
• Adjustable wrench
• 1/2” Open-end wrench
3KLOOLSVKHDGVFUHZGULYHU
)ODWEODGHGVFUHZGULYHU
(blade approximately
3/32” across)
1XWGULYHUV´´
or 7mm
Pressure Regulator *DV9DOYH
PROPANE (LP) CONVERSION INSTRUCTIONS
PROPANE
NAT
Rotate cap counter-
clockwise to loosen
Cap assembly
WARNING
Explosion Hazard
Death or serious injury can result from failure to follow
these instructions.
6HUYLFHE\DTXDOLILHGVHUYLFHWHFKQLFLDQRQO\
6KXWRIIJDVVXSSO\DQGGLVFRQQHFWSRZHUEHIRUHVHUYLFLQJ
5HFRQQHFWDOOJURXQGLQJGHYLFHVDIWHUVHUYLFH
Replace all parts and panels before operating.
NOTICE:
,I\RXDUHXVLQJSURSDQH/3ERWWOHGJDVDOO
adjustments described in the following steps must be
made before you make any burner adjustments.
NOTICE:
6DYHWKHVHRUL¿FHVIRUIXWXUHFRQYHUVLRQEDFNWRQDWXUDOJDV
WARNING
'RQRWRSHUDWHWKHFRRNWRSRURYHQ
burners of this range when using propane (LP) (bottled) gas
EHIRUHFRQYHUWLQJWKHSUHVVXUHUHJXODWRUDQGEXUQHURUL¿FHV
for propane (LP) gas use. Failure to do so could cause high
ÀDPHVDQGWR[LFIXPHVZKLFKFDQUHVXOWLQVHULRXVLQMXU\
7KHSUHVVXUHUHJXODWRUDQGWKHEXUQHURUL¿FHVDUHVHWIRU
natural gas. To use propane (LP) gas, the regulator and burner
RUL¿FHVPXVWEHFRQYHUWHG
',QVWDOOWKHSURSDQH/3RUL¿FHVLQWKHLUSUHFLVHORFDWLRQV
7RSUHYHQWOHDNDJHPDNHVXUHWKHRUL¿FHVSXGVDUHVHFXUHO\
screwed into the gas supply tubes.
(,QVWDOOWKHROGRUL¿FHVSXGVLQWRWKHPHWDOER[RUEUDFNHW
along with these instructions, and replace onto the back of the
UDQJHIRUSRVVLEOHIXWXUHFRQYHUVLRQ
95
III
Denotes 0.95mm Orifice size opening
Denotes LP (Propane)
Burner
cap
Burner construction
Burner
head
Base
Orifice
located
through this
opening
LR
RR
LF RF
Blue/Magenta
Propane
Blue/Brown
Propane
Blue/Brown
Propane
Red/Yellow
Propane
PROPANE (LP) CONVERSION INSTRUCTIONS
31-11148 04-18 GEA
JGBS10, JGBS30, RGBS300, RGBS400 and JGBS60
7KHSURSDQHRUL¿FHVIRUWKHFRRNWRSEXUQHUVDUHVKLSSHGRQ
the back of the range in the location shown.
3URSDQH&RQYHUVLRQ.LW
CONVERTING THE OVEN BURNERS
ADDITIONAL INFORMATION
OVEN BURNER ORIFICE
 5HPRYHRYHQGRRUEURLOGUDZHURYHQERWWRPDQGEXUQHU
7KHRYHQEXUQHURUL¿FHLVORFDWHGEHKLQGWKHGUDZHU2Q
VRPHPRGHOVDPHWDOVKLHOGPXVWEHUHPRYHG
 7RFRQYHUWWRSURSDQH/3UHSODFHRYHQRUL¿FHZLWKWKH
one supplied in kit with range.
NOTICE:
7KLVSURGXFWFDQQRWEHFRQYHUWHGWRSURSDQH/3E\
DGMXVWLQJWKHRYHQRUL¿FHV7KHRUL¿FHVPXVWEHUHSODFHG
for propane (LP).
NOTICE:
2QFHWKHFRQYHUVLRQLVFRPSOHWHDQGFRQ¿UPHG¿OORXWWKH
propane (LP) sticker and include your name, organization
DQGGDWHFRQYHUVLRQZDVPDGH$SSO\WKHVWLFNHUWRWKH
range near the regulator to alert others in the future that
WKLVDSSOLDQFHKDVEHHQFRQYHUWHGWRSURSDQH/3,I
FRQYHUWLQJEDFNWRQDWXUDOJDVIURPSURSDQH/3SOHDVH
UHPRYHWKHVWLFNHUVRRWKHUVNQRZWKHDSSOLDQFHLVVHWWR
use natural gas.
NOTICE:
6DYHWKHVHRUL¿FHVIRUIXWXUHFRQYHUVLRQEDFNWRQDWXUDOJDV
BURNER OUTPUT RATINGS: BTU/HR
NG (Natural) Gas 5” W.C.P.
BURNER
BTU
RATE
ORIFICE
SIZE (mm) COLOR MARKING
RF 13,000 0.064" (1.62) Black/Red 162N
LF 9,500 0.053" (1.36) *UHHQ 136N
RR 5,000 0.040" (1.01) White/Purple 101N
LR 9,500 0.053" (1.36) *UHHQ 136N
OVEN 18,000 0.076” (1.93) None .076
198
III
Denotes 1.98mm Orifice size opening
Denotes Natural Gas
N
ADJUSTING AIR SHUTTER SETTINGS
FOR OVEN BURNERS
 :LWKD3KLOOLSVKHDGVFUHZGULYHUORRVHQWKHVFUHZV
securing the air shutter on the bake burner. Adjust the air
shutter to fully open.
2. Turn on the gas.
3. Turn on the electricity.
 5HLQVWDOOWKHRYHQGRRU
5. Turn on the bake burner.
2YHQEXUQHUÀDPHPXVWEHREVHUYHGZLWKWKHGRRUFORVHG
WRSURSHUO\FKHFNÀDPHFKDUDFWHULVWLFV
 $V\RXZDWFKWKHÀDPHZLWKWKHRYHQGRRUFORVHGFKHFN
WKHIROORZLQJWKURXJKWKHRYHQGRRUZLQGRZRUWKURXJKWKH
broil drawer opening.
D,IWKHÀDPHVDUH\HOORZRSHQWKHDLUVKXWWHUPRUH
E,IWKHÀDPHVEORZDZD\RUÀXWWHUIURPWKHEXUQHUFORVH
the air shutter slightly.
 &KHFNLQJWKHÀDPHVL]H
,WVKRXOGEHDSSUR[LPDWHO\´WR
3/4” long for the bake burner.
7KHFRPEXVWLRQTXDOLW\RIWKH
EXUQHUÀDPHVQHHGVWREH
GHWHUPLQHGYLVXDOO\
127(,IEXUQHUÀDPHVORRNOLNH$IXUWKHUDLUVKXWWHU
adjustment to the bake buner is required. Normal
EXUQHUÀDPHVVKRXOGORRNOLNH%RU&GHSHQGLQJRQ
the type of gas you use. With propane (LP) gas, some
\HOORZWLSSLQJRQWKHRXWHUFRQHVLVQRUPDO
)RUHLJQSDUWLFOHVLQWKHJDVOLQHPD\FDXVHDQRUDQJHÀDPHDW
¿UVWEXWWKLVZLOOVRRQGLVDSSHDU
8.
When all adjustments are made and the results are
satisfactory:
a. Retighten the air shutter screws.
E5HSODFHWKHRYHQERWWRP
SPECIAL NOTE:
To convert the oven back to natural gas, reverse the
instructions given in making propane (LP) adjustments.
Screw
Air shutter
WARNING
,I\RXDWWHPSWWRPHDVXUHWKHLQQHUFRQH
RIWKHÀDPHSOHDVHXVHFDXWLRQEXUQVFRXOGUHVXOW
WARNING
The following adjustments must be made
EHIRUHWXUQLQJRQWKHJDVWRWKHRYHQEXUQHU)DLOXUHWR
GRVRFRXOGUHVXOWLQVHULRXVLQMXU\GXHWRKLJKÀDPHVDQG
toxic fumes.
2YHQEXUQHU
air shutter
2YHQ
orifice
PROPANE (LP) CONVERSION INSTRUCTIONS
31-11148 04-18 GEA
JGBS10, JGBS30, RGBS300, RGBS400 and JGBS60
(A) Yellow flames:
Further Adjustment
Required
(B) Yellow tips on
outer cones:
Normal for Propane (LP) Gas
(C) Soft blue flames:
Normal for Natural Gas
/