Crestron SPC-550 User manual

  • Hello! I am an AI chatbot trained to assist you with the Crestron SPC-550 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Crestron SPC-550 SmartPresenter™ Cable
Crestron Electronics, Inc. Operations Guide - DOC. 5782
15 Volvo Drive SmartPresenter™ Cable: SPC-550
Rockleigh, NJ 07647 07.99
Tel: 888.CRESTRON Specifications subject to change without notice.
Fax: 201.767.7576 www.crestron.com
SmartPresenter™ Cable: SPC-550
The SPC-550 is designed for the SmartPresenter™ and used to control specific
serially-controlled devices. The entire length of the cable is approximately 15 feet
(4.572 meters) with a RJ11 (6-position, 6-pin) connector at one end and a
8-pin DIN connector at the other end.
Physical View of the SPC-550
UNMARKED PINS
ARE NOT CONNECTED
RED (TX)
GRN (RX)
VIEWED FROM SOLDER SIDE
(NOTE OFFSET OF PIN 4)
7
8 6
5 3
4
12
BLK (GND)
15 FEET
(4.572 METERS)
WHT
PIN #1
NOTE: Alteration of the SPC-550
in any manner may affect its
performance within the control
system. Crestron cannot
guarantee its behavior if altered.
A serially-controlled device can be controlled with the SmartPresenter™ only if the
appropriate Q-Code is assigned to OUTPUT 4 on the SP-1. The SP-1 recognizes the
Q-Code as an RS-232 switching device and outputs commands for that device to the
PC port (rather than the OUTPUT 4 port). Use the SPC-550 to connect the SP-1 to
the serially-controlled device (refer to illustration below). Only those devices with a
cable code “e” designation in the Crestron Q-Codes table (latest version of the
SmartPresenter Quick Guide, Doc. 5742) require the SPC-550.
Hookup Connection for Controlling a Serially-Controlled Device
SPC-550
SERIALLY-CONTROLLED
DEVICE
/