  • Hello! I'm a chat assistant and I've analyzed the Luminii Kilo Recessed and Kilo Recessed Corners Installation Instructions. This document provides details on installing the Kilo KR- and KRC- models, including electrical connections, proper cutouts, and joining sections. I'm ready to help answer any questions you might have about the installation process or the product's capabilities described in the document.
  • What is the required power for Kilo Recessed lights?
    Can Kilo Recessed lights be installed in a closet?
    What type of locations are Kilo Recessed lights suitable for?
    Do i need access above the ceiling?
REV2.9 April 20, 2021 3:19 PM
Kilo Recessed & Kilo Recessed Corners - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATIONS WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models KR-, & KRC-
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE WITH COMPATIBLE CLASS 2 OR CLASS P POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DAMP LOCATIONS
5. SUITABLE FOR INSTALLATION WITHIN THE CLOSET
STORAGE SPACE
6. ACCESS ABOVE CEILING REQUIRED
7. TYPE IC (CEILING & WALL)
8. INHERENTLY PROTECTED Page 1 of 4
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
1
2
3
A
2.1
3.1
3.1
B
2.04”
2.87” 2.87”2.93” 2.93”
1.50”
4.00”
Option A: If the Kilo Recessed LED lead wires
will be connected to 24VDC power
wires in a remote junction box.
Option B: If the Kilo Recessed LED lead wires
will be connected to 24VDC power
wires inside provided junction box on
top of Kilo Recessed.
kilo recessed cut-out
set screws
joiner
measure to determine cut-out length
Details
kilo recessed
corner cut-out
(if applicable)
kilo recessed
straight section
kilo recessed
corner section
1.5” CUT
0.30”
0.38”
2.1 Determine the location of the installation. Measure the fixture(s) length (excluding the flanges on the ends of the endcap), and then cut a 1.5” wide
cut-out all along the desired location.
3.2 Determine the location of the installation. Measure the fixture(s) length (excluding the flanges on the ends of fixtures), and then cut a 1.5” wide
cut-out all along the desired location.
3.1 If joining sections together as asystem
align the joiners to thecorresponding
section end. Followedby inserting then
tightening the setscrews to secure.
REV2.9 April 20, 2021 3:19 PM
Kilo Recessed & Kilo Recessed Corners - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATIONS WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models KR-, & KRC-
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE WITH COMPATIBLE CLASS 2 OR CLASS P POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DAMP LOCATIONS
5. SUITABLE FOR INSTALLATION WITHIN THE CLOSET
STORAGE SPACE
6. ACCESS ABOVE CEILING REQUIRED
7. TYPE IC (CEILING & WALL)
8. INHERENTLY PROTECTED Page 2 of 4
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
ssuurrffaaccee
rotate rotate
lead wires
spring clip
spring clip
kilo recessed
kilo recessed
4
5
5.1
5.1
Option A: Run the fixture(s) lead wire to the remote power supply. Refer to page 3 for wiring.
Option B: Connect the 24VDC power wires to the Kilo Recessed LED wires inside the nearest junction box Refer to step 7 for wiring. Once wires are secure,
attach the junction box to the back of Kilo Recessed with the provided screws, make sure all wires & connection are inside junction box.
5.1 Rotate the fixture spring clips into the top position, to allow fixture to slide through the cutout slot. Followed by carefully releasing spring clips and
push the fixture completely into the slot. If necessary make any surface or paint imperfection prior to installation.
4.1
kilo recessed
kilo recessed
junction box junction box
Option A Option B
REV2.9 April 20, 2021 3:19 PM
Kilo Recessed & Kilo Recessed Corners - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATIONS WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models KR-, & KRC-
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE WITH COMPATIBLE CLASS 2 OR CLASS P POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DAMP LOCATIONS
5. SUITABLE FOR INSTALLATION WITHIN THE CLOSET
STORAGE SPACE
6. ACCESS ABOVE CEILING REQUIRED
7. TYPE IC (CEILING & WALL)
8. INHERENTLY PROTECTED Page 3 of 4
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
6
7 8
Multiple run option
power from remote
power supply
junction
box conduit
(not shown for clarity) junction box
add pigtails & run
to next fixture
wires from remote
power supply
wires
from fixture
surface Kilo
Recessed
7.1
7. 2 8.1
8.1
6.1 To connect multiple runs, connect fixture wires to the power supply wires in addition to adding pigtails. Run the pigtail wires to the next fixture to power.
7.1 If necessary, plaster and finish any imperfection on the surface of
the cutout.
7.2 Carefully snap diffuser lens into the extrusion then remove
theprotective film from the front of the diffuser lens.
8.1 Ensure power is off to power supply! Then proceed to connect the
Kilo Recessed lead wires to power supply. Connect +24VDC red
wire from Kilo Recessed to power supply +24VDC red wire with
appropriate wire nut. Connect -24VDC black wire from Kilo Recessed
to power supply -24 VDC black wire with appropriate wire nut.
protective film
Kilo Recessed
class 11
power
supply
120 VAC 24 VDC to fixture(s)
+24VDC (RD) +24VDC (RED)
-24VDC (BLK) -24VDC (BLK)
REV2.9 April 20, 2021 3:19 PM
Kilo Recessed & Kilo Recessed Corners - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATIONS WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models KR-, & KRC-
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE WITH COMPATIBLE CLASS 2 OR CLASS P POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DAMP LOCATIONS
5. SUITABLE FOR INSTALLATION WITHIN THE CLOSET
STORAGE SPACE
6. ACCESS ABOVE CEILING REQUIRED
7. TYPE IC (CEILING & WALL)
8. INHERENTLY PROTECTED Page 4 of 4
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Multiple powerfeed layouts
power supply
low voltage wires
fixture 1
power supplies at the
end of the run
power supplies in the
middle of the run
consecutive layout,
NOT RECOMMENDED
fixture 1
fixture 1
fixture 2
fixture 2
fixture 2
low voltage wires
low voltage wireslow voltage wires
power supply
power supplypower supply
/