luminii STR-XX-GS-XX Installation guide

Type
Installation guide

The luminii STR-XX-GS-XX is a recessed track system designed for indoor, dry locations, primarily for commercial and residential lighting purposes. It is compatible with a range of lighting fixtures and accessories, allowing for flexible and customizable lighting solutions.

The system operates on a 24-volt DC power supply and utilizes a three-circuit track design for added versatility in lighting configurations. The recessed design blends seamlessly into ceilings, providing a sleek and unobtrusive appearance.

The luminii STR-XX-GS-XX is a recessed track system designed for indoor, dry locations, primarily for commercial and residential lighting purposes. It is compatible with a range of lighting fixtures and accessories, allowing for flexible and customizable lighting solutions.

The system operates on a 24-volt DC power supply and utilizes a three-circuit track design for added versatility in lighting configurations. The recessed design blends seamlessly into ceilings, providing a sleek and unobtrusive appearance.

REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 1 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
IMPORTANT SAFETY INSTRUC TIONS!
WHEN INSTALLING OR USING THIS TRACK SYSTEM, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING:
A. READ ALL INSTRUCTIONS.
B. DO NOT INSTALL THIS TRACK IN DAMP OR WET LOCATIONS.
C. DO NOT INSTALL ANY PART OF THE TRACK SYSTEM LESS THAN 5 FEET ABOVE THE FLOOR.
D. DO NOT INSTALL ANY LUMINAIRE ASSEMBLY CLOSER THAN 6 INCHES FROM ANY CURTAIN, OR SIMILAR COMBUSTIBLE MATERIAL.
E. DISCONNECT ELECTRICAL POWER BEFORE ADDING TO OR CHANGING THE CONFIGURATION OF THE TRACK.
F. DO NOT ATTEMPT TO ENERGIZE ANYTHING OTHER THAN LIGHTING TRACK LUMINAIRES ON THE TRACK. TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, DO NOT
ATTEMPT TO CONNECT POWER TOOLS, EXTENSION CORDS, APPLIANCES, AND THE LIKE TO THE TRACK.
Recessed Track System
REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 2 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
90°
90°
1.3 Slide the contact strip back into the extrusion.
1
1.1
1.1 Slide the power track out of the extrusion.
1.3 Slide the power track back into the extrusion
Field Cutting Instructions
1.2 When cutting the extrusion in field, ensure that the extrusion
is sitting perpendicular to the cutting surface.
1.4 Trim the power track with hand shears to fit the length
of the extrusion.
REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 3 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
2
3
2.1 Determine the location of where the fixture(s) will be installed. Mounting brackets should be spaced 4” from each end of the fixture(s) and also every
24” in between to evenly distribute weight.
2.2 Slide the square nuts through the
slot on the backside of the recessed
channel. Please note, make sure to
not install any end caps (powered
or blank) before these square nuts
are slotted through the back of the
extrusion.
2.4 Tighten the 10-32 x 1/4” hex head screws
through the recessed spring brackets and into
the square nuts, securing the recessed spring
brackets to the backside of the recessed track
housing.
2.3 Bring down the recessed spring brackets to
the backside of the recessed channel and
line the holes up with the square nuts from the
previous step. Please make sure the spring
brackets alternate in direction.
3.1 Slide on the Endcap 3.2 Tighten the set screw.
Luminii recommends not to exceed 24ft or 3 track joiners per power feed to minimize system voltage drop and avoid output variation across the run.
Long runs of track can be accomplished using multiple power feeds. See page 8 for details on converting a joiner to a power feed using accessory
TJ-1-72.
Mounting Bracket Installation – MB-STR
Blank Endcap Installation – EC-STR-H3-XX
4” 24”
fixed clip
spring bracket
recessed track housing
hex head screw
set screw
3 .1
3.2
REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 4 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
It is recommended to perform these steps before the track housing is installed on the ceiling.
Be sure to mount the spring brackets to the back of the housing before this section.
Installation Using Power Feed Endcap - PF-STR-XX
4
4.1 Start by removing the magnetic finish
plate on the Power Feed Endcap.
Then loosen the cover plate screws.
Remove cover plate after the screws
are loosened. Flip up the power feed
connector to get it out of the way for
now.
4.2 Slide the power feed end cap onto the
housing then tighten the two set screws
on the back of the track housing to
secure the power feed end cap to the
track housing.
4.3 Flip down and snap in the power feed
connector to the power track housing.
Perform a continuity check between the
track conductors and the power feed
connector wires to ensure the connector is
seated properly in the track.
4.4 Re-attach the cover plate and tighten its
screws to secure it to the power feed end
cap.
4.5 Once the cover plate is secure, attach the
magnetic finish plate to it.
magnetic
finish plate
cover plate
power feed connector
power feed
end cap
track housing
power feed
connector
power feed
connector
magnetic finish
plate
REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 5 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Installation Using Power Feed Endcap - PF-STR-XX (continued)
4
4.6 Cutout a slot in the ceiling according to the
dimensions given in the image above.
Please note, the length of the slot cutout
in the ceiling should be 0.1” longer than
your track length when all pieces (power
feed end caps, joiners, track housing) are
attached.
4.8 Bend the adjustable springs to a straight position, followed by pushing the Track Housing completely inside the cutout slot. The springs will release to
secure the Track Housing to the mounting surface. It is easier to insert the fixture at an angle into the drywall.
4.7 Route power feed cable through the cutout slot in the mounting surface. Connect the power
feed wires to the remote power supply. For more information, please refer to the power supply
wiring instructions.
4.7
2.89”
1.05”
1.12”
2.54”
1.16”
0.94”
0.85”
4.8
recessed track
cutout slot
recessed track
cutout slot
REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 6 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Installation of Joiners
5
Use the same installation method for the L-joiner as the straight power
feed joiner
Use the same installation method for the X-joiner as the straight
power feed joiner
Use the same installation method for the T-joiner as the straight power
feed joiner
Straight Joiner
T-Joiner
L-Joiner
X-Joiner
REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 7 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Installation of Joiners (continued)
5
power feed joiner
power track
housing
power track
housing
magnetic finish plate
power feed
connector
cover plate
5.1 Remove the magnetic finish
plate on the Power Feed
Joiner. Remove cover plate
after the screws are loosened.
Remove power feed
connector to gain access to
two set screws shown in the
next step.
5.2 Loosen the now exposed set screws, then remove the
coupling plates.
5.5 Slide the joiner end cap over the coupling plate and secure by tightening the set screw on the power track joiner.
5.4 Install the 1st track section per Step #2.6-2.8.
5.3 Now slide the coupling plates to the backside
of the track housing, then secure it to the
housing by tightening the set screws
coupling
plate
coupling
plate
coupling plate
power track
joiner
set screw
set screw
REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 8 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Installation of Joiners (continued)
5
5.6 Install the next power track through the cut out slot and slide it to the previously installed power joiner and secure it using the set screw on the power
joiner end cap.
5.7 Snap in the power feed connector to either end of the power track
housing. Perform a continuity check between the track conductors to
ensure the connector is seated properly in the track. If you have power
feeds on each end, skip this step to provide electrical isolation.
5.9 Once the cover plate is secure, attach the magnetic finish
plate to it.
5.8 Re-attach the cover plate and tighten its screws to secure it to the
power feed joiner.
power feed connector
cover plate
power feed connector
magnetic
finish plate
REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 9 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Converting a Joiner to a Power Feed
6
6.1 Open joiner and discard the electrical jumper.
6.3 Insert TJ-1-72 into the bushing just installed.
6.2 Replace the hole plug with the provided bushing.
6.4 Repeat steps 3.2 - 3.9 from the “Installation of Joiners” Section
to attach the converted joiner to the track housing. Once the
converted power feed joiner is installed to both sides of the track
housing, snap in TJ-1-72 into the desired section of track that you
want powered.
For long continuous runs and closed patterns (i.e. rectangle), power feeds may need to be added to the Joiners. The following steps describe how to
convert a standard Joiner to a Power Feed Joiner using TJ-1-72.
Discard
electrical
jumper
provided
bushing
provided
bushing
TJ-1-72
REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 10 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Module and Cover Installation
7
power feed end cap
track housing
power feed joiner
directional
module
ambient
module
track cover
track
housing
CORRECT INCORREC T
directional
module
directional
module
7.1
7.1
7.1 Carefully align then snap the ambient or directional module fixture into the surface/
recessed track housing. When doing this installation, it is easier to install each fixture at
an angle like in the image above. Be careful to ensure that the module has full connection
to the track and isn’t sitting at an odd angle (see picture to the left).
7.3 To remove the directional or ambient modules from the track
housing, use the provided plastic tool to pry out the modules
from the ends. It is easier to remove one end at a time as in the
image shown.
Note: Total wattage of installed modules must not exceed 96W, 4A
Maximum per power feed.
7.2 Track covers may be cut to length
in the field and installed between
modules to create a closed
aesthetic look.
track cover
ambient
module
track cover
directional
module
7. 2
7. 2
Plastic Tool
REV0.9 July 11, 2022 4:23 PM
Stenos Track System - Installation Instructions
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read complete instruction prior to installation and keep for future reference!
Models STR-XX-GS-XX
1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR DRY LOCATIONS ONLY
5. RECESSED TRACK IS TYPE IC (CEILING & WALL) INHERENTLY
PROTECTED Page 11 of 11
7777 N. Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Module and Cover Installation (continued)
7vertical position
tilted position
7.4 The directional modules can be aimed+/-30° by loosening the rotation lockingscrews and setting to the
desired angle. Retighten the rotation locking screws before inserting the directional module into the track
housing to lock in the desired angle.
7.6 The power track contains three copper conductors: The center
conductor is a common positive (+), while the outer conductors are
separate negatives (-).
7.7 The ambient and directional modules have asymmetric electrical contact
pins that allow for 2-channel installations depending upon the module
orientation when inserted into the track housing. This 2-channel feature
of the power track allows for the creation of two separately controllable
lighting zones. For example, all ambient modules can be controlled on
channel #1 and all directional modules can be controlled on channel #2.
7.8 If only 1 channel control is desired, the separate negative (-) power feed
wires can be tied together when wiring the remote power supply.
7.5 Optional lens accessories
simply snap into fixture head of
the Stenos Directional Module.
lens accessory
channel 1, negative (-)
channel 2, negative (-)
positive (+)
module connected to channel 1 module connected to channel 2
6.6
7. 6
positive (+)
negative (-)
rotate 180°, if connecting
to other circuit
rotation
locking
screw
Caution: Do Not Overtighten
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

luminii STR-XX-GS-XX Installation guide

Type
Installation guide

The luminii STR-XX-GS-XX is a recessed track system designed for indoor, dry locations, primarily for commercial and residential lighting purposes. It is compatible with a range of lighting fixtures and accessories, allowing for flexible and customizable lighting solutions.

The system operates on a 24-volt DC power supply and utilizes a three-circuit track design for added versatility in lighting configurations. The recessed design blends seamlessly into ceilings, providing a sleek and unobtrusive appearance.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI