Aruba 580EX Series Hazardous Location Outdoor Access Points Installation guide

Type
Installation guide

This manual is also suitable for

Aruba 580EX Series Hazardous Location
Outdoor Access Points
Installation Guide
Rev 01 | March 2022 1
The Aruba 580EX Series hazardous location outdoor access points (AP-585EX and AP-587EX) support the IEEE
802.11ax standard, delivering high performance with the MIMO (Multiple-Input, Multiple-Output) and OFDMA
(Orthogonal Frequency Division Multiple Access) technologies, while also supporting 802.11a/b/g/n/ac wireless
services.
Package Contents
580EX Series access point
Cable gland (Type: 20A2F) x 2
USB Type-C console cable x 1
Ground lug kit x 1
Tools Required
Phillips screwdriver (#2 for M4x6 screw)
Flat blade screwdriver (for Ethernet and AC port cap)
The weatherproof caps for Ethernet, AC and Console interfaces are connected to the access point, not loose in
the package.
Mounting kits for use with the 580EX Series access points are sold separately. Contact your Aruba sales
representative for details.
Inform your supplier if there are any incorrect, missing, or damaged parts. If possible, retain the carton,
including the original packing materials. Use these materials to repack and return the unit to the supplier if
needed.
2Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide
Hardware Overview
Figure 1 AP-585EX Front View
Figure 2 AP-585EX Rear View
E1/SFP+ E2/PSE E0/PoE+ Grounding Point
AC Power Port
USB Console Port,
Reset Button and
LED
Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide 3
Figure 3 AP-587EX Front View
Figure 4 AP-587EX Rear View
LED
The 580EX Series access point is equipped with one LED that indicates the system status of the access point.
E1/SFP+ E2/PSE E0/PoE+ Grounding Point
AC Power Port
USB Console Port,
Reset Button and
LED
4Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide
Table 1 580EX Series LED Meanings during Boot Up
1. Mostly off (off 6 seconds, then one blink flash)
2. Equally off/on (off 1 second, then red 1 second)
Table 2 580EX Series LED Meanings during Operation
Ethernet Ports
The 580EX Series access point is equipped with three Ethernet ports:
E0 PoE+ port: 100/1000/2500/5000Base-T auto-sensing MDI/MDI-X wired network port (RJ45). The E0 port
supports PoE-in, allowing the AP to draw power from an 802.3at/802.3bt PoE power source.
E1 SFP+ port: 10GBASE-R SFP+ port.
E2 PSE port: 100/1000Base-T auto-sensing MDI/MDI-X wired network port (RJ45). The AP supports 802.3af
PoE-Out when PoE powered, and supports up to 802.3at when powered by AC.
PoE input rating is 57V max|0.3A. 0.3A is per pair of wires in Ethernet cable. Ethernet cable has 4 pair of wires in
total.
AC Power Port
The 580EX Series access point is equipped with an AC power port. The 580EX Series access point does not ship
with any AC power cables. Aruba offers an AC power connector kit (sold separately) for customers to assemble
their own AC power cable.
Grounding Point
Always remember to protect the access point by installing the grounding line first before connecting to a
network and applying power. Additionally, if removing or taking down the AP, the grounding line should be the
last item disconnected.
LED Color/State Meaning
System LED Off No power to AP
Red Initial power-up
Flashing - Green AP booting, not ready
On - Green AP ready. GbE (or better) or SFP+ connected. The LED turns off
after 1200 seconds
Green - Yellow, 6 seconds
period AP ready. 100Mb connected. The LED turns off after 1200
seconds
Green - Flashing1AP in deep sleep
Red - Flashing2AP in thermal shutdown
LED Color/State Meaning
System LED Solid Red General fault - Immediate attention required
One red blink every 3
seconds Radio 0 fault (5 GHz)
Two quick red blinks 0.5
seconds apart cycled every
3 seconds
Radio 1 fault (2.4GHz)
To enable 802.3at support on E2, Intelligent Power and Temperature Monitoring (IPTM) must be enabled on
the AP to properly monitor and maintain safe operations of the AP under higher power draw requirements. If
IPTM is disabled, the maximum PoE support on E2 is 802.3af.
Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide 5
USB Type-C Console Port
Use the included USB Type-C console cable to connect the access point to a laptop or a serial terminal for direct
management.
Reset Button
The reset button can be used to reset the access point to factory default settings or turn off/on the LED display.
There are two ways to reset the access point to factory default settings:
Reset the AP during normal operation
Press and hold down the reset button using a small, narrow object such as a paper clip for more than 10
seconds during normal operation.
Reset the AP while powering up
1. Press and hold down the reset button using a small, narrow object such as a paper clip while the access point
is not powered on via PoE.
2. Connect the power supply (PoE) to the access point while the reset button is being held down.
3. Release the reset button on the access point after 15 seconds.
To turn off/on the LED display, press and release the reset button using a small, narrow object, such as a
paperclip for less than 10 seconds during normal operation of the access point.
Before You Begin
Refer to the sections below before beginning the installation process.
Pre-Installation Checklist
Before installing your access point, be sure that you have the following:
Cat5E or better shielded cable with network access
A compatible PoE injector with power cord
One of the following network services:
Aruba Discovery Protocol (ADP)
DNS server with an “A” record
DHCP Server with vendor specific options
!
FCC Statement: Improper termination of access points installed in the United States configured to non-US
model controllers will be in violation of the FCC grant of equipment authorization. Any such willful or
intentional violation may result in a requirement by the FCC for immediate termination of operation and may
be subject to forfeiture (47 CFR 1.80).
Aruba, in compliance with governmental requirements, has designed the 580EX Series access points so that
only authorized network administrators can change configuration settings. For more information about AP
configuration, refer to the AP Software Quick Start Guide.
!
Access points are radio transmission devices and as such are subject to governmental regulation. Network
administrators responsible for the configuration and operation of access points must comply with local
broadcast regulations. Specifically, access points must use channel assignments appropriate to the location in
which the access point will be used.
6Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide
Outdoor Planning and Deployment Considerations
Prior to deploying an outdoor wireless network, the environment must be evaluated to plan for a successful
WLAN deployment. Successfully evaluating the environment enables the proper selection of access points and
antennas and assists in the determination of their placement for optimal RF coverage. This process is considered
WLAN or RF planning and Aruba’s system engineers can assist in the outdoor planning process.
Identifying Specific Installation Locations
Use the access point placement map generated by the Aruba RF Plan software application to determine the
proper installation location(s). Each location should be as close as possible to the center of the intended
coverage area and should be free from obstructions or obvious sources of interference. These RF absorbers/
reflectors/interference sources will impact RF propagation and should be accounted for during the planning
phase and adjusted for in the RF plan.
Identifying Known RF Absorbers/Reflectors/Interference Sources
Identifying known RF absorbers, reflectors, and interference sources while in the field during the installation
phase is critical. Make sure that these sources are taken into consideration when you attach an access point to its
fixed location.
RF absorbers include:
Cement/concrete—Old concrete has high levels of water dissipation, which dries out the concrete, allowing
for potential RF propagation. New concrete has high levels of water concentration in the concrete, blocking
RF signals.
Natural Items—Fish tanks, water fountains, ponds, and trees
Brick
RF reflectors include:
Metal Objects—Metal pans between floors, rebar, fire doors, air conditioning/heating ducts, mesh windows,
blinds, chain link fences (depending on aperture size), refrigerators, racks, shelves, and filing cabinets.
Do not place an access point between two air conditioning/heating ducts. Make sure that access points are
placed below ducts to avoid RF disturbances.
RF interference sources include:
Other Wi-Fi networks
Microwave ovens
Bluetooth devices
Access Point Installation
The rules for the 5600-5650 MHz band vary by region.
!
Use of this equipment in near proximity, either horizontally or vertically, with other equipment should be
avoided because it could result in improper operation. If such use is necessary, this equipment and the other
equipment should be observed to verify that they are operating normally.
Service to all Aruba products should be performed by trained service personnel only.
Metal cover of enclosure is intended for installation in restricted access location.
Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide 7
Using Mount Kits
The 580EX Series access point can be installed on a wall or attached to a pole by using mount kits:
Grounding the Access Point
Grounding the access point must be completed before powering up the device. The ground wire should be #8
AWG.
1. Strip the insulating jacket off of one end of the ground wire and place the bare conductor into the ground lug
(included in the package), then crimp the connection by pressing firmly with the crimping pliers.
2. Fasten the ground lug to the grounding point on the access point with the screw included in the package.
Connecting the Ethernet Cable
To connect the Ethernet cable to the access point, perform the following steps using the cable glands that ship
with your access point.
Table 3 Applicable Mount Kits for 580EX Series Access Point
Part Number Description Supported Model
R9H97A AP-OUT-MNT-V1A Aruba Outdoor AP Pole/
Wall Long Mount Kit. AP-585EX: Wall or Pole
JW054A AP-270-MNT-H1 Aruba Outdoor AP
Hanging or Tilt Install Mount Kit. AP-587EX: Wall or Pole
AP-585EX: Flat or Sloped Ceiling
JW055A AP-270-MNT-H2 Aruba Outdoor AP Access
Flush Wall or Ceiling Mount. AP-587EX: Wall
AP-585EX: Flat Ceiling
R6W11A AP-270-MNT-H3 Aruba Outdoor AP
Hanging or Dual-Tilt Install Mount Kit. AP-587EX: Wall or Pole
AP-585EX: Flat or Sloped Ceiling
The 580EX Series access point does not ship with any mount kits. These mount kits are available as accessories
and must be ordered separately.
For installation instructions on mount kits, please refer to their respective installation guides found on the
Aruba support site https://asp.arubanetworks.com.
!
This 580EX Series access point is intended for installation in a RESTRICTED ACCESS LOCATION attached to a
pole or installed on a wall. Installers should disconnect power before working with or near the access point.
!
To prevent dropping and damage to the 580EX Series access point or to appendages of the handlers, extra
care should be taken when handling the access point.
!
Failure to use the included cable glands can lead to connectivity and PoE issues.
The cable is not included and must be purchased separately. Purchase a suitable UV-resistant, outdoor rated,
CAT 5E or better shielded cable for use with the access point.
8Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide
Figure 5 Ethernet Cable and 20A2F Cable Gland Assembly
1. Remove the dust cap from the Ethernet port
2. Slide the sealing nut, seal A, seal B, gland body and O-ring over the cable.
3. Insert the RJ45 connector to the Ethernet port.
4. Place the O-ring on the gland body, and ensure it is in place.
5. Thread the gland body into the Ethernet port and tighten to a torque of 70.5 in/lbs (8 Nm).
6. Push the seal B and seal A into the gland body and tighten the sealing nut onto the gland body to a torque of
53 in/lbs (6 Nm).
Figure 6 Ethernet Cable and 20A2F Cable Gland Installed to AP
Connecting the Fiber-optic Cable
Aruba provides a CKIT-EX-OD-SFP SFP gland kit (sold separately) to connect the fiber-optic cable to the AP. Refer
to the 580EX Series ordering guide on the Aruba website https://www.arubanetworks.com. The CKIT-EX-OD-SFP
SFP gland kit includes a SFP extension tube and a 20A2F gland, as shown in Figure 7.
Ethernet Cable
O-ring
Gland Body
Seal B
Seal A Sealing Nut
The fiber-optic cable is not included in the package and must be purchased separately. Purchase a suitable 6-
12 mm diameter, UV-resistant, outdoor rated cable for use with the access point.
Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide 9
Figure 7 Fiber-optic Cable and CKIT-EX-OD-SFP SFP Gland Kit
To connect the fiber-optic cable to the access point, perform the following steps.
1. Remove the dust cap from the E1 SFP+ port.
2. Insert the transceiver module into the SFP+ port, and ensure it is in place.
3. Slide the sealing nut, seal A, seal B, gland body, O-ring and SFP extension tube over the fiber-optic cable.
4. Insert the connector of the fiber-optic cable into the transceiver module, and ensure the connector is firmly
in place.
5. Screw the SFP extension tube into the E1 SFP+ port and tighten to a torque of 88 in/lbs (10 Nm).
6. Place the O-ring on the gland body, and ensure it is in place.
7. Thread the gland body into the SFP extension tube and tighten to a torque of 70.5 in/lbs (8 Nm).
8. Push the seal B and seal A into the gland body and tighten the sealing nut onto the gland body to a torque of
53in/lbs (6 Nm).
Fiber-optic Cable
O-ring Gland Body
Seal B
Seal A Sealing Nut
SFP Extension Tube
For more details on the 20A2F cable gland such as conditions of use, installation instructions and technical
data, please refer to CMP website:
https://www.cmp-products.com/Installation%20Instructions/CMP%20A2F.pdf
10 Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide
Figure 8 Fiber-optic Cable and CKIT-EX-OD-SFP SFP Gland Kit Installed to AP
Connecting the AC Power Cable
Best Practice for Outdoor Connection to AC Mains
In all circumstances and with any outdoor infrastructure the recommended practice is to connect to AC mains in
an outdoor grade weather protected junction box. This needs to be implemented by a qualified resource in a
manner that is consistent with the electrical code in force in the jurisdiction of deployment. In many countries
this will require a licensed electrician to perform this operation. In Japan, this would be performed by a Certified
Electrician by Ministry of Economy, Trade and Industry.
The use of plugs with infrastructure equipment is suitable only for temporary installs where nuisance tripping of
GFI plugs is considered tolerable. if a plug is desired for attachment to the cable assemblies then the installer is
expected to follow all directions provided with the plug end in a fashion consistent with local electrical code.
The 580EX Series access point does not ship with any AC power cables. Aruba offers an AP-AC-MLX-EX outdoor
Molex AC connector kit (sold separately) for customers to assemble their own AC power cable and connect the
AC power cable to the AP. For installation instructions, refer to the AP-AC-MLX-EX AC Connector Kit Installation
Guide shipped with the AP-AC-MLX-EX kit.
Software
For instructions on choosing operating modes and initial software configuration, refer to the AP Software Quick
Start Guide.
Verifying Post-Installation Connectivity
The integrated LEDs on the access point can be used to verify that the access point is receiving power and
initializing successfully (see Table 1 and Table 2). Refer to the AP Software Quick Start Guide for further details
!
!
Aruba access points are classified as radio transmission devices, and are subject to government regulations of
the host country. The network administrator(s) is/are responsible for ensuring that configuration and operation
of this equipment is in compliance with their country’s regulations. For a complete list of approved channels in
your country, refer to the Aruba Downloadable Regulatory Table at https://www.arubanetworks.com/techdocs/DRT/
Default.htm
Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide 11
on verifying post-installation network connectivity.
Electrical and Environmental Specifications
Electrical
Ethernet
E0 PoE+ port: 100/1000/2500/5000Base-T auto-sensing MDI/MDI-X wired network port (RJ45). The E0 port
supports PoE-in, allowing the AP to draw power from an 802.3at/802.3bt PoE power source.
E1 SFP+ port: 10GBASE-R SFP+ port.
E2 PSE port: 100/1000Base-T auto-sensing MDI/MDI-X wired network port (RJ45). The AP supports 802.3af
PoE-Out when PoE powered, and supports up to 802.3at when powered by AC.
Power over Ethernet (PoE): 57V max, 0.3A
Power
AC input: 100-240V, 50-60Hz, 1.4A
Environmental
Operating
Temperature: -40ºC to 65ºC (-40ºF to 149ºF)
Storage
Temperature: -40ºC to 70ºC (-40ºF to 158ºF)
Humidity: 5% to 93% non-condensing
For additional specifications on this product, please refer to the data sheet at www.arubanetworks.com.
Regulatory Model Number
For the purpose of regulatory compliance certifications and identification, this product has been assigned a
unique regulatory model number (RMN). The regulatory model number can be found on the product nameplate
label, along with all required approval markings and information. When requesting compliance information for
this product, always refer to this regulatory model number. The regulatory model number RMN is not the
marketing name or model number of the product.
The following regulatory model numbers apply to the 580EX Series:
AP-585EX RMN: APEX0585
AP-587EX RMN: APEX0587
Safety and Regulatory Compliance
If the 580EX Series access point is deployed supporting Fiber, PSE, and high user loads in extremely hot
temperatures or in hot environments with large solar loading environments, it is strongly recommended to
enable Intelligent Power and Temperature Monitoring (IPTM) to ensure continuous uninterrupted operations,
allowing the AP to disable specific and user-definable features to ensure continuity and prevent a thermal
shutdown of the AP.
!
RF Radiation Exposure Statement: This equipment complies with RF radiation exposure limits. This
equipment should be installed and operated with a minimum distance of 9.84 inches (25cm) between the
radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter.
12 Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide
United States
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the manufacturer’s instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio or TV technician for help.
Improper termination of access points installed in the United States configured to a non-US model controller is a
violation of the FCC grant of equipment authorization. Any such willful or intentional violation may result in a
requirement by the FCC for immediate termination of operation and may be subject to forfeiture (47 CFR 1.80).
Innovation, Science and Economic Development Canada
This Class B digital apparatus meets all of the requirements of the Canadian Interference-Causing Equipment
Regulations.
In accordance with Innovation, Science and Economic Development Canada regulations, this radio transmitter
and receiver may only be used with an antenna, the maximum type and gain of which must be approved by
Innovation, Science and Economic Development Canada. To reduce potential radio interference, the type of
antenna and its gain shall be chosen so that the equivalent isotropic radiated power (EIRP) does not exceed the
values necessary for effective communication.
This device complies with Innovation, Science and Economic Development Canada's license-exempt RSS
regulations. Operation of this device is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that may cause undesired
operation.
When operated in 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to reduce the
potential for harmful interference with co-channel Mobile Satellite Systems.
Innovation, Sciences et Développement économique Canada
Cet appareil contient un ou plusieurs transmetteurs/récepteurs exempts de licence conformes aux RSS exempts
de licence d’Innovation, Sciences et Développement économique Canada. L’utilisation de ce périphérique est
soumise aux deux conditions suivantes: (1) Cet appareil ne doit pas produire d’interférences. (2) Cet appareil doit
accepter toutes les interférences, y compris les interférences pouvant engendrer un fonctionnement indésirable
!
Déclaration de la concernant l’exposition aux rayonnements à fréquence radioélectrique (FR): Cet
appareil est conforme aux limites d’exposition aux rayonnements FR établies par la FCC. Il doit être installé et
utilisé à une distance minimale de 25 cm (9,84 pouces) entre le radiateur et votre corps, qu’il opère sur la
bande 2,4 GHz ou 5 GHz. Cet émetteur ne doit pas être installé ou utilisé à proximité immédiate d’une autre
antenne ni d’un autre transmetteur.
!
The device could automatically discontinue transmission in case of absence of information to transmit, or
operational failure. Note that this is not intended to prohibit transmission of control or signaling information
or the use of repetitive codes where required by the technology.
!
Changes or modifications to this unit not expressly approved by the party responsible for compliance could
void the user’s authority to operate this equipment.
!
Toute modification effectuée sur cet équipement sans l'autorisation expresse de la partie responsable de la
conformité est susceptible d'annuler son droit d'utilisation.
Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide 13
de l’appareil.
En cas d'utilisation dans la plage de fréquences de 5,15 à 5,25 GHz, cet appareil doit uniquement être utilisé en
intérieur afin de réduire les risques d'interférence avec les systèmes satellites mobiles partageant le même
canal.
European Union Regulatory Conformance
The Declaration of Conformity made under Radio Equipment Directive 2014/53/EU is available for viewing at:
www.hpe.com/eu/certificates. Select the document that corresponds to your device’s model number as it is
indicated on the product label.
Wireless Channel Restrictions
5150-5350MHz band is limited to indoor only in the following countries; Austria (AT), Belgium (BE), Bulgaria (BG),
Croatia (HR), Cyprus (CY), Czech Republic (CZ), Denmark (DK), Estonia (EE), Finland (FI), France (FR), Germany (DE),
Greece (GR), Hungary (HU), Iceland (IS), Ireland (IE), Italy (IT), Latvia (LV), Liechtenstein (LI), Lithuania (LT),
Luxembourg (LU), Malta (MT), Netherlands (NL), Norway (NO), Poland (PL), Portugal (PT), Romania (RO), Slovakia
(SK), Slovenia (SL), Spain (ES), Sweden (SE), Switzerland (CH), Turkey (TR), United Kingdom (UK(NI)).
Medical
1. Equipment not suitable for use in the presence of flammable mixtures.
2. Connect to only IEC 60950-1 or IEC 60601-1 certified products and power sources. The end user is
responsible for the resulting medical system complies with the requirements of IEC 60601-1.
3. Wipe with a dry cloth, no additional maintenance required.
4. No serviceable parts, the unit must be sent back to the manufacturer for repair.
5. No modifications are allowed without Aruba approval.
Taiwan
第十二條
經型式認證合格之低功率射頻電機,非經許可,公司,商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能
第十四條
低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用
前項合法通信,指依電信法規定作業之無線電通信。 低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干
擾。
1. 應避免影響附近雷達系統之操作。
2. 高增益指向性天線只得應用於固定式點對點系統。
3. 電波功率密度 MPE 標準值:1 mW/cm2,送測產品實測值: 0.9638 mW/cm2,建議使用時設備天線至少距離人體 25cm。
Brazil
Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência
em sistemas devidamente autorizados.
Radio Frequency Range MHz Max EIRP
BLE/Zigbee 2402-2480 10 dBm
Wi-Fi
2412-2472 20 dBm
5150-5250 23 dBm
5250-5350 23 dBm
5470-5725 30 dBm
5725-5850 14 dBm
!
Lower power radio LAN product operating in 2.4 GHz and 5 GHz bands. Please refer to the ArubaOS User Guide/
Instant User Guide for details on restrictions.
14 Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide
Japan
México
La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o
dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debeaceptar cualquier interferencia,
incluyendo la que pueda causar su operación no deseada.
Este equipo ha sido diseñado para operar con las antenas que enseguida se enlistan:
https://www.arubanetworks.com/assets/og/OG_AP-580Series.pdf y para una ganancia máxima de antena de 14
dBi.
El uso con este equipo de antenas no incluidas en esta lista o que tengan una ganancia mayor que 14 dBi
quedan prohibidas. La impedancia requerida de la antena es de 50 ohms.
Нормативные требования Евразийского Экономического Союза
HPE Russia: ООО "Хьюлетт Паккард Энтерпрайз" Российская Федерация, 125171, г.
Москва, Ленинградское шоссе, 16А, стр.3, Телефон: +7 499 403 4248 Факс: +7 499 403
4677
'HPE Kazakhstan': TOO «Хьюлетт-Паккард (К)», Республика Казахстан, 050040, г.
Алматы, Бостандыкский район, проспект Аль-Фараби, 77/7, Телефон/факс: + 7 727
355 35 50
Kazakhstan
ЖШС "Хьюлетт Паккард Энтерпрайз" Ресей Федерациясы, 125171, Мәскеу, Ленинград тас жолы, 16A блок
3, Телефон: +7 499 403 4248 Факс: +7 499 403 4677
ЖШС «Хьюлетт-Паккард (К)», Қазақстан Республикасы, 050040, Алматы к., Бостандык ауданы, Әл-Фараби
даңғ ылы, 77/7, Телефон/факс: +7 (727) 355 35 50
Ukraine
Hereby, Hewlett Packard Enterprise Company declares that the radio equipment type [The Regulatory Model
Number [RMN] for this device can be found in the Regulatory Model Number section of this document] is in
compliance with Ukrainian Technical Regulation on Radio Equipment, approved by resolution of the CABINET OF
MINISTERS OF UKRAINE dated May 24, 2017, No. 355. The full text of the UA declaration of conformity is
available at the following internet address: https://certificates.ext.hpe.com/public/certificates.html
ХЮЛЕТТ ПАКАРД ЕНТЕРПРАЗ, 6280 АМЕРИКА ЦЕНТР Д-Р, САН-ХОСЕ, КАЛІФОРНІЯ 95002, США
Special Requirement for Safe Use
WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
The connections on this equipment are not intended to be connected or disconnected when an explosive
atmosphere is present.
Only EX-certified personnel are allowed for on-site installation and electrical connections of equipment.
Manual switch TPS3851H18EDRBR is protected by at least an IP66 enclosure, it is not allowed to operate the
switch in a hazardous area.
Required protection shall be applied to avoid the high risk of mechanical damage occurred by the final
installation.
The equipment must be installed and used in an area of at least pollution degree 2, as defined in IEC 60664-1.
Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide 15
Only ATEX/IECEx certified cable glands as specified in the instructions are to be installed and used on the
enclosure, and IEC/EN 60079-14 shall be observed when installing. Suitable type of protection cable gland to
be selected with spec: M20x1.5 with minimum IP66 rating. Unused cable entry ports to be blocked by Ex
plugs with minimum IP66 rating.
Earthing system shall be finished in accordance with user manual before use.
Damaged Protective Vents have to be replaced immediately.
Type-C USB port is not to be used in hazardous area.
Standard Compliance
EN IEC 60079-0:2018
EN IEC 60079-7:2015/A1:2018
IEC 60079-0:2017 Edition 7.0
IEC 60079-7:2015+A1:2017 Edition 5.1
CSA C22.2 No.213-17
UL 121201 Ninth Edition
ATEX Certificate Number and Marking
TÜV 21 ATEX 8711 X
IECEx Certificate Number and Marking
IECEx TUR 21.0041X
Ex ec IIC T4 Gc
cCSAus Ex Marking
Class I, Division 2, Groups A, B, C and D T4
The equipment is intended to use in outdoor and environmentally challenging locations such as oil rigs, mining
facilities, and industrial plants, networks need to be protected from extreme temperatures, flammable gases
or vapors, and dust concentrations.
The equipment to be used in Zone 2 or CID2 hazardous area only with gas group IIC or Groups A, B,C and D.
16 Aruba 580EX Series Hazardous Location Outdoor Access Points | Installation Guide
Contact Aruba
Copyright
© Copyright 2022 Hewlett Packard Enterprise Development LP
Open Source Code
This product includes code licensed under the GNU General PublicLicense, the GNU Lesser General Public License, and/or
certain other open source licenses.
A complete machine-readable copy of the source code corresponding to such code is available upon request. This offer is valid
to anyone in receipt of this information and shall expire three years following the date of the final distribution of this product
version by Hewlett Packard Enterprise Company.
To obtain such source code, send a check or money order in the amount of US $10.00 to:
Hewlett Packard Enterprise Company
Attn: General Counsel
6280 America Center Drive
San Jose, CA 94089
USA
Warranty
This hardware product is protected by an Aruba warranty. For more details, visit www.hpe.com/us/en/support.html
Main Site https://www.arubanetworks.com
Support Site https://asp.arubanetworks.com
Airheads Social Forums and Knowledge Base https://community.arubanetworks.com/
North America Telephone 1-800-943-4526
1-408-754-1200
International Telephone https://www.arubanetworks.com/support-services/contact-support/
Software Licensing Site https://www.hpe.com/networking/support
End-of-Life Information https://www.arubanetworks.com/support-services/end-of-life/
Security Incident Response Team (SIRT) https://www.arubanetworks.com/support-service/security-bulletins/
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Aruba 580EX Series Hazardous Location Outdoor Access Points Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI