Tynetec ZXT350 User guide

Type
User guide
DocNo.FM0727issueDPage1
169MHzTelecareDevices
RangeExtender
__________________________________________________________________________________________________________
 

Compatiblewith169MHzTelecareonReachathomealarms,Adventxt
wardencall,AltecResponseandTouchsafeProNursecallsystems
Integralalarmbutton&statusLEDindicator
Freestandingorwallmountingoptions
PlugtopswitchmodePSUmodule(3mlead)
Integralrechargeablestandbybattery(24hourstypical)
Dimensions:120x187x38mm(HxWxD)Weight:495grams
ProductCode:ZXT350
WhatistheRangeExtenderusedfor?
Therangeextenderisusedtoincreasetheareaofcoveragefor169MHzTelecareradiodevicesusedwithReachathomealarms,
Adventxtwardencallsystems,TouchsafeProNursecallsystemsandAltecResponselocalcarealarms.
Forexample,inthehometherangeextendercanbeplacedonabackwindowsilltoensureanalarmcallcanstillbereceived
fromtheuser’spersonalpendantiftheyneedassistancewheninthebackgarden.InshelteredhousingorNursinghomesthe
rangeextendercanbefittedtoachieveradiocoverageinblindspotsnotcoveredbythenetworkreceivers.
Pleasenote;whenusedwiththepersonalpendant,ifthelocalManagerorControlCentrecannothearthecallertheystillknow
wherethecalliscomingfrom,thepersonalpendantdoesnotpickupvoice,andtherangeextenderdoesnotextendaudio,the
extenderonlyincreasestherangeatwhichTelecareperipheralscanbeused.
WhereshouldtheRangeExtenderbelocated?
Therangeextenderisnormallyfreestandingandcanbesimplyplacedonatableorshelfinthehome,howeveritcanalsobe
permanentlywallmounted.TherangeextenderisforinternaluseonlyDONOTSITEOUTDOORS.
.
Therangeextendermustbewithin3metresofamainssupplyotherwiseamainsextensioncablewillberequired,ifanextension
isusedtakecaretoensurenoonecantriponthelead.
Pleasenote;theunitmeetstheEN300220category1classificationwhichisdesignedtoreducetheeffectsofinterference,butas
withallradiotransmissions,therangeoftheunitcanbeaffectedbyenvironmentalfactorsandbuildingfabric.Toconfirmthe
operationofeachdeviceyoushouldalwaystesttherangeextenderinlocationwiththeperipheraldevicesthatwillbeused.
RangeExtenderInstallation
Chooseasuitableindoorlocationapprox.midwaybetweenthefurthestpointyouwanttoachieveradiocoverageandthe
athomealarmunit(ornetworkreceiver/localalarmunit).
  




 

ConnecttheswitchmodePSUmodule
betweentheSUPPLYsocketand
themainssupply.
Carefullyfittheaerialby
screwingitintothebrass
aerialsocketonthetop
leftcorneroftheunit.
Range
Extender
ReachAtHome
AlarmUnit
Typically60metresTypically 60metres
SUPPLY
ZXT350 RANGE
Freq. 169 .48125MHz
Env. Group II
Made in UK
8
5
2
0
*
1
4
7
#
3
6
9
tynetec
SMPSU MODULE (3m LEAD)
MAINS SUPPLY
RANGE EXTENDER
DO NOT
UNPLUG
OR
SWITCH OFF
EXTENDER/REPEATER
Personal
Pendant
Tynetec andAidcallare businessunitsofLegrandElectricLtd
Unit10CowleyRoad,BlythRiversideBusinessPark,Blyth
Northumberland,NE245TF.Tel:01670352371Fax:01670362807
Email:[email protected]Web:www.tynetec.co.uk
DocNo.FM0727issueDPage2
RangeExtenderSetup
OnpowerupthefrontstatusLEDshouldilluminateSTEADYGREEN,ifnotdoesnotlightchecktheON/OFFswitchinsidethe
batterycoverisintheONposition.
RangeExtenderProgramming
Pleasenotetheunitcanonlybeprogrammedwithinthefirst5minutesofpowerup.
PressandholdtheRED(())buttontocyclethroughtheprogrammodeoptions,aseachoptionisreachedthefrontstatusLED
willflashRED.Releasethebuttonafterthefirstflashtoselectoption1,releaseafterthesecondflashtoselectoption2etc.
Option1:Enable/Disablethe“SurveyMode”AudibleIndication
Ifenabledtheunitwill“beep”wheneveraradiosignalisreceivedthisshouldonlybeusedduringinstallationandtesting.
PressandholdtheRED(())buttonandreleaseaftertheFIRSTREDFLASH.
Thenumberofbeepsindicatesifthe“SurveyMode”audibleindicationisenabledordisabled;
1beep=disabled(defaultsetting),2beeps=enabled
Totogglebetweenenabled/disabled;pressandholdtheRED(())buttonandreleaseaftertheFIRSTREDFLASHagain.
Option2:Enable/Disablethe“SignalReceived”VisualIndication
IfenabledtheSTEADYGREENfrontstatusLEDwillFLASHOFFwheneveraradiosignalisreceived.
PressandholdtheRED(())buttonandreleaseaftertheSECONDREDFLASH.
Thenumberofbeepsindicatesifthe“SignalReceived”visualindicationisenabledordisabled;
1beep=disabled(defaultsetting),2beeps=enabled
Totogglebetweenenabled/disabled;pressandholdtheRED(())buttonandreleaseaftertheSECONDREDFLASHagain.
Option3:Disable1169MHzor869MHzRadioReceivers
Thisoptionisnotapplicabletotherangeextender;itisusedonthetranslator/repeaterproductonly(TynetecZXT360).
Option4:Changethe169MHzTransmitterID
Innormaloperatingmodetheunit’sRED(())buttoncanbepressedtoactivateanalarmcallontheathomealarmunit.The
rangeextenderhas4differentpreprogrammedradioID’s;adifferentIDmayneedtobeselectediftwoormorerangeextenders
arewithinradiorangeofeachother.
PressandholdtheRED(())buttonandreleaseaftertheFOURTHREDFLASH.
Thenumberofbeepsindicatesthecurrent169MHzradioIDsetting;
1beep=ID920001(defaultsetting),2beeps=ID920003,3beeps=ID920005&4beeps=ID920007
Tostepthroughthesettings;pressandholdtheRED(())buttonandreleaseaftertheFOURTHREDFLASHagain.
Ifyouhavemorethan4rangeextenderswithinrangeofeachotherpleasecontactTynetec’sCustomerServicesforadvice.
Option5:Enable/DisableWardenCallMode
IftheunitisbeinginstalledonanAdventxtwardencallsystemthenthismodeshouldbeenabledtoincreasethemasktimeand
helppreventrepeatalarmsfromthesamedevice.
PressandholdtheRED(())buttonandreleaseaftertheFIFTHREDFLASH.
Thenumberofbeepsindicatesifthe“AdventxtMode”isenabledordisabled;
1beep=disabled,2beeps=enabled(30secondmasktime)
Totogglebetweenenabled/disabled;pressandholdtheRED(())buttonandreleaseaftertheFIFTHREDFLASHagain.
Option6:FactoryTestMode
Thisoptionisusedtoenteranautomatedtestingprogrammeandisnotintendedforserviceuse.
GREENBUTTON(NotUsed)
YELLOWBUTTON(NotUsed)
RED(())BUTTON
UsedtomakeanEMERGENCYalarm
call and forprogrammingtheunit
FRONTSTATUSLED
SteadyGreen=Normal
FlashingGreen=SignalReceived
FlashingRed=ProgramModeOption
FlashingAmber=MainsSupplyFailure
169MHz
Range Extender
DocNo.FM0727issueDPage3
8
5
2
0
*
1
4
7
#
3
6
9
BATTERY
PACK
OFF
DO NOT
UNPLUG
OR
SWITCH OFF 169MHz
Range Extender
169MHz
Range Extender
RangeExtenderMountingOptions
Therangeextenderissuppliedwithverticalstandfortablemountingand
aconnectorcoveriftheunitisbeingplacedflatorwallmounted.
BotharefixedwiththesingleM3x8mmscrewsuppliedinthepackingtray.
Thecardboardcartonhasawallmountingtemplateontheinnerflap.
NOTE:whentheunitiswallmountedtheaerialisontheBOTTOMFACE.
SwitchingtheRangeExtenderOff
TherangeextenderusesverylittlepowerandshouldalwaysbeleftswitchedON.
IfitisnecessarytoswitchtheunitOFFfollowtheprocedurebelow;
Turnthemainssupplyoffandwaituntiltheunitsounds5BeepsandthefrontstatusLEDFLASHESAMBER
5 Beeps…
PressandholdtheRED(())buttonuntiltheunit“Beeps”oncethenrelease…
  1Beep
TherangeextenderisnowturnedOFF.
RangeExtenderBatteryIsolationSwitch
Therangeextendercanbeswitchedoffiftheunitisgoingtobestoredornotusedforaprolongedperiod.
Removethestand(iffitted)toaccessthebatterycoverontherear.
Undothescrew,removethebatterycoverandcarefully
liftthebatterypackoutofitscompartment.
MovetheswitchtotheLEFTtoturntheunitOFF.
Refitthebatterypack,batterycoverandfixingscrew.

Note:thebatterypackwillremainconnectedonashortwire.

RangeExtenderBatteryLife
DetailedinformationonbatterymanagementforallTynetec/Aidcallproductsisavailableinaseparatedocument.
ContactCustomerServicesandrequestacopyofDocNo.FM0630.
Vertical
Stand
Connector
Cover
SwitchOf
f
DocNo.FM0727issueDPage4
UsingtheRangeExtenderwithaReachathomealarmunit
TherangeextendermustberegisteredontotheReachathomealarmunitsoanemergencycallfromtheintegralRED(())
buttonwillberecognized.Seebelowforhowtoenter“LearnMode”onReachathomealarms.
Therangeofallradiodevicescanbeaffectedbytheworkingenvironment‐alwaystakecareduringinstallationand
performseveraltestcallstoensurereliableoperation.
RegisteringtheRangeExtenderontoaReachathomealarmunit
1.PuttheReachunitintoradiodevicelearnmode…

    


2.Activatetherangeextender…

  


3.Exitradiodevicelearnmode…

    


4.CheckwiththeControlCentrethatitisconvenienttoperformatestcall,activatethependantwithinrangeoftherange
extenderandconfirmtheyreceiveapendantalarmcall.
UsingtheRangeExtenderwithWardenCall/NursecallSystemsandLocalCareAlarms
TherangeextenderdoesnotneedtoberegisteredontoAdventxtwardencallsystems,TouchsafeProNursecallsystemsorAltec
Responselocalcarealarms.
Therangeextendersimplyretransmitsany169MHzsignalitreceiveswithinitsrange;thisretransmissionwillthenbepickedup
bytheclosestnetworkreceiveronawardencall/Nursecallsystemorthelocalcarealarmunit.
ThereisnoneedtolearntheRED(())buttonontothewardencall,Nursecallorlocalcarealarmasintheseapplicationstherange
extenderitselfitdoesnotrelatetoaspecificflatnumber.
Furthermore,inwardencall,Nursecallorlocalcarealarmapplications,thetranslator/repeaterwillprobablybewallmountedout
ofsightandtheRED(())buttonwillneverbeusedbyaresidenttoinitiateanalarmcall.
TynetecandAidcalloperateapolicyofcontinuousimprovementandreservestherighttochangeproductspecificationswithoutnotice.
IfanyvariationtothedetailscontainedinthisdocumentaresuspectedpleasecontactTynetec’scustomersupportdepton01670352371.
Trigger
Radio
Device
PressandHOLDtheGREENbuttonontheReachunit.
WhenthefrontlightFLASHESFASTGREENreleasethe
buttonandtheReachwillannounceTriggerRadioDevice”.
Younowhave1minutetoactivatetherangeextender.
PresstheGREENbuttonontheReachunit.
ThefrontlightwillreturntoSTEADYGREENandtheReach
isbackinnormaloperatingmode.
PresstheRED(())buttonontherangeextenderandthe
ReachwillannouncePendant”.