ELTA FANS AVIO Series Installation guide

Category
Household fans
Type
Installation guide

This manual is also suitable for

ELTA FANS AVIO Series is an axial fan best suited for small to medium sized rooms and for use cases such as extracting air from bathrooms or kitchens. It can be used for air discharge directly to the outside or in the presence of short linear ducts (less than 1.5m). It is suitable for in-line installation, both vertical and horizontal. The fan has been constructed with a high quality, impact and UV resistant ABS material, and can be operated continuously or intermittently. It has double insulation, removing the need for an earth connection. The AVIO Series has a high efficiency aerodynamic fan with winglet blades to optimise quietness and efficiency.

ELTA FANS AVIO Series is an axial fan best suited for small to medium sized rooms and for use cases such as extracting air from bathrooms or kitchens. It can be used for air discharge directly to the outside or in the presence of short linear ducts (less than 1.5m). It is suitable for in-line installation, both vertical and horizontal. The fan has been constructed with a high quality, impact and UV resistant ABS material, and can be operated continuously or intermittently. It has double insulation, removing the need for an earth connection. The AVIO Series has a high efficiency aerodynamic fan with winglet blades to optimise quietness and efficiency.

1
G
Installation manual
AVIO - Axial fan
Fig. 1
PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE
Read this manual carefully before using the product and keep
it in a safe place for reference.
This product was constructed up to standard and in compliance
with regulations relating to electrical equipment and must be
installed by technically qualified personnel.
The manufacturer assumes no responsibility for damage to persons
or property resulting from failure to observe the regulations
contained in this booklet.
•Thedeviceshouldnotbeusedforapplicationsotherthanthosespeciedinthismanual.
•Afterremovingtheproductfromitspackaging,verifyitscondition.Incaseofdoubt,
contactaqualiedtechnician.Donotleavepackagingwithinthereachofsmallchildren
or people with disabilities.
•Donottouchtheappliancewithwetordamphands/feet.
•Thisappliancecanbeusedbychildrenagedfrom8yearsandaboveandpersonswith
reducedphysical,sensoryormentalcapabilitiesorlackofexperienceandknowledge
if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.
•Do not use the product in the presence of ammable vapours, such as alcohol,
insecticides,gasoline,etc...
•Ifanyabnormalitiesinoperationaredetected,disconnectthedevicefromthemains
supplyandcontactaqualiedtechnicianimmediately.Useoriginalsparepartsonlyfor
repairs.
•Theelectricalsystemtowhichthedeviceisconnectedmustcomplywithregulations.
•Beforeconnectingtheproducttothepowersupplyorthepoweroutlet,ensurethat:
- the data plate (voltage and frequency) correspond to those of the electrical mains
-theelectricalpowersupply/socketisadequateformaximumdevicepower.Ifnot,
contactaqualiedtechnician.
•The device should not be used as an activator for water heaters, stoves, etc., nor
shoulditdischargeintohotair/fumeventductsderivingfromanytypeofcombustion
unit.Itmustexpelairoutsideviaitsownspecialduct.
•Operatingtemperature:0°Cupto+50°C.
•Thedeviceisdesignedtoextractcleanaironly,i.e.withoutgrease,soot,chemicalor
corrosiveagents,orammableorexplosivemixtures.
•Donotleavethedeviceexposedtoatmosphericagents(rain,sun,snow,etc.).
•Donotimmersethedeviceoritspartsinwaterorotherliquids.
•Turnoffthemainswitchwheneveramalfunctionisdetectedorwhencleaning.
•For installation an omnipolar switch should be incorporated in the xed wiring, in
accordancewiththewiringregulations,toprovideafulldisconnectionunderovervoltage
categoryIIIconditions(contactopeningdistanceequaltoorgreaterthan3mm).
•Ifthesupplycordisdamaged,itmustbereplacedbythemanufacturer,itsservice
2
STANDARD
ThefanisoperatedusingaseparateON/OFFswitchorviaalightswitch(Fig.8A).
WITH TIMER (over-run)
Thefanisprovidedwithatimercircuitwhichisadjustablefromaprox.1minuteto25
minutesviatrimmer(Fig.9B).
Operation:connectedaccordingtothediagraminFig.8B,afterthelightisswitchedon,
thefanactivateswithadelayofmax1.5seconds.Afterthelightisswitchedoff,thefan
continues to function for a pre-set period of time.
VERSIONS
agentorsimilarlyqualiedpersonsinordertoavoidahazard.
•Donotobstructthefanorexhaustgrilletoensureoptimumairpassage.
•Ensureadequateairreturnintotheroomincompliancewithexistingregulationsin
order to ensure proper device operation.
•Iftheenvironmentinwhichtheproductisinstalledalsohousesafuel-operatingdevice
(waterheater,methanestoveetc.,thatisnota“sealedchamber”type),itisessentialto
ensureadequateairintake,toensuregoodcombustionandproperequipmentoperation.
•Installtheproductsothattheimpeller is notaccessiblefromtheairoutletsideas
veried by contact with the Test Finger (test probe “B” of the norm EN61032) in
compliance with the current safety regulations.
•Material:Highquality,impactandUV-resistantABScolourRAL9010.
•High efficiency aerodynamic fan with “winglet” blades to optimise quietness and
efficiency.
•Singlephaseinductionmotorwithintegralthermalprotection.
•Motormountedonhighqualitysleevebearings.
•Thefanisdoubleinsulated:noearthconnectionisrequired.
•Suitableforcontinuousorintermittentoperation.
•IPX4degreeofprotection.
•Powersupply220Vto240V~ 50/60Hz.
TECHNICAL SPECIFICATIONS
Code
Airflow m
3
/h max
Static pressure
Pa max
Power
W max
Sound pressure
dB(A) @3m
L/s m
3
/h
AVIO100 23.5 84 24 8 34
AVIO125 45.7 163 43 14 40
AVIO150 88.6 312 57 24 46
INTRODUCTION
AVIO(Fig.1)isanaxialfandesignedtoensureairextractioninsmall/medium-sizedrooms
suchasbathrooms,toiletsandkitchens.
Suitableforairdischargedirectlytotheoutsideorinthepresenceofshortlinearduct
(lessthan1.5m).Forin-lineinstallation(Fig.2),horizontalorvertical.
2014/35/EULowVoltageDirective(LVD)
2014/30/EUElectromagneticCompatibility(EMC),
inconformitywiththefollowingstandards:
ElectricalSafety:EN60335-1(2012)+A11+A13;EN60335-2-80(2003)+A1+A2.
ElectromagneticCompatibility:EN55014-1(2017);EN55014-2(2015);EN61000-3-
2(2014);EN61000-3-3(2013).
STANDARD CONFORMITY
3
INSTALLATION (Fig. 2)
shortlengthducting(lessthan1.5m)
verticalceiling-min.height2,3m
4
B
OA
dimensioni serie QIN
MODELLO Ø A B
100
99 80
120
119 90
150
148 100
4
6
3
5
MOUNTING AND ELECTRICAL WIRING
Ø
AVIO100= ø99 mm
AVIO125= ø119 mm
AVIO150= ø148 mm
Ø
d
Ø
d
7
AVIO100 - AVIO125 - AVIO150
8A
9A
5
AVIO100T - AVIO125T - AVIO150T
8B
9B
TIMER
+
-
ACCESSORY ON DEMAND
11
12
10
6
Informationondisposalofunitsattheendoflife.
ThisproductcomplieswithEUDirective2002/96/EC.
The symbol of the crossed-out dustbin indicates that this product must be
collected separately from other waste at the end of its life.The user must,
therefore,disposeoftheproductinquestionatsuitableelectronicandelectro-
technicalwastedisposalcollectioncentres,orelsesendtheproductbacktothe
retailerwhenpurchasinganew,equivalenttypedevice.
Separatecollectionofdecommissionedequipmentforrecycling,treatment
and environmentally compatible disposal helps to prevent negative effects
on the environment and on health and promotes the recycling of the materials
that make up the equipment.
Improperdisposaloftheproductbytheusermayresultinadministrative
sanctions as provided by law.
DISPOSAL AND RECYCLING
MAINTENANCE / CLEANING
Theunitshouldbecleanedregularlyasexplainedinthisleaettomaintainperformance
and warranty cover. Cleaning should be carried out as and when required but please note
intervalsbetweencleaningshouldnotexceed6months.Theinstallershouldexplainthis
cleaningregimetothehomeowner/occupierandaskthehomeowner/occupiertokeepa
recordofthecleaningdoneonthisleaetasthiswillberequiredtobeprovidedbythe
homeowner/occupiertoclaimagainstanyproductfailureunderwarranty.
Year Required Maintenance
1 Inspect,cleanifrequired
2 Inspect,cleanifrequired
3 Inspect,cleanifrequired
7
ErP Directive - Regulations 1253/2014 1254/2014
a) Mark - ELTA FANS
b) Model -
AVIO100,
AVIO100T
AVIO125,
AVIO125T
AVIO150,
AVIO150T
c) SEC class - E E E
c1) SEC warm climates kWh/m2.a -2,6 -3 -3,8
c2) SEC average climates kWh/m2.a -10,2 -10,7 -11,4
c3) SEC cold climates kWh/m2.a -23,6 -24,1 -24,8
Energy label - No
d) Unit typology - Residenal - unidireconal
e) Type of drive - single speed drive
f) Type of Heat Recovery System - absent
g) Thermal eciency of heat recovery % N/A
h) Maximum ow rate m3/h 76 154 309
i) Electric power input at maximum ow rate W 8,3 14,6 22,8
j) Sound power level (L
WA
) dBA 55 60 66
k) Reference ow rate m3/h 76 154 309
l) Reference pressure dierence Pa 10 10 10
m) Specic power input (SPI) W/m3/h 0,109 0,095 0,074
n1) Control factor - 1
n2) Control typology - Manual control (no DCV)
o1) Maximum internal leakage rate % N/A
o2) Maximum external leakage rate % N/A
p1) Internal mixing rate % N/A
p2) External mixing rate % N/A
q) Visual lter warning - N/A
r) Instrucons to install regulated grilles - check the instrucon booklet
s) Internet address for pre/disassembly instrucons - www.eltafans.com
t) Airow sensivity to pressure variaons % N/A 25 16
u) Indoor/outdoor air ghtness m3/h 57 102 170
v1) AEC - Annual electricity consumpon - warm climates kWh 1,5 1,3 1
v2) AEC - Annual electricity consumpon - average climates kWh 1,5 1,3 1
v3) AEC - Annual electricity consumpon - cold climates kWh 1,5 1,3 1
w1) AHS - Annual heang saved - warm climates kWh 6,3 6,3 6,3
w2) AHS - Annual heang saved - average climates kWh
14 14 14
w3) AHS - Annual heang saved - cold climates kWh 27,3 27,3 27,3
CFI00012-06-0818
EltaFansLimited
BuildingServices
46ThirdAvenue
PensnettTradingEstate
Kingswinford
WestMidlands
DY67US
UnitedKingdom
T:+44(0)1384275800
F:+44(0)1384275810
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

ELTA FANS AVIO Series Installation guide

Category
Household fans
Type
Installation guide
This manual is also suitable for

ELTA FANS AVIO Series is an axial fan best suited for small to medium sized rooms and for use cases such as extracting air from bathrooms or kitchens. It can be used for air discharge directly to the outside or in the presence of short linear ducts (less than 1.5m). It is suitable for in-line installation, both vertical and horizontal. The fan has been constructed with a high quality, impact and UV resistant ABS material, and can be operated continuously or intermittently. It has double insulation, removing the need for an earth connection. The AVIO Series has a high efficiency aerodynamic fan with winglet blades to optimise quietness and efficiency.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI