11
a) Mark - ELTA FANS
b) Model -
ARCO A 120, ARCO A 120T, ARC0 A 120C
c) SEC class - E
c1) SEC warm climates kWh/m2.a -2,5
c2) SEC average climates kWh/m2.a -10,2
c3) SEC cold climates kWh/m2.a -23,6
Energy label - No
d) Unit typology - Residenal - unidireconal
e) Type of drive - single speed drive
f) Type of Heat Recovery System - absent
g) Thermal eciency of heat recovery % N/A
h) Maximum ow rate m3/h 151
i) Electric power input at maximum ow rate W 16,3
j) Sound power level (L
WA
) dBA 49
k) Reference ow rate m3/s 151
l) Reference pressure dierence Pa 10
m) SEC warm climates W/m3/h 0,107
n1) Control factor - 1
n2) Control typology - Manual control (no DCV)
o1) Maximum internal leakage rate % N/A
o2) Maximum external leakage rate % N/A
p1) Internal mixing rate % N/A
p2) External mixing rate % N/A
q) Visual lter warning - N/A
r) Instrucons to install regulated grilles - check the instrucon booklet
s) Internet address for preassembly/disassembly instrucons - www.eltafans.com
t) Airow sensivity to pressure variaons
EN
13141 - 8
S3
u) Indoor/outdoor air ghtness
EN
13141 - 8
D2
v1) AEC - Annual electricity consumpon - warm climates kWh 1,4
v2) AEC - Annual electricity consumpon - average climates kWh 1,4
v3) AEC - Annual electricity consumpon - cold climates kWh 1,4
w1) AHS - Annual heang saved - warm climates kWh 6,3
w2) AHS - Annual heang saved - average climates kWh 13,9
w3) AHS - Annual heang saved - cold climates kWh 27,3
a) Mark - ELTA FANS
b) Model -
ARCO A 120HT, ARCO A 120HTC
c) SEC class - C
c1) SEC warm climates kWh/m2.a -9,4
c2) SEC average climates kWh/m2.a -23,8
c3) SEC cold climates kWh/m2.a -48,8
Energy label - No
d) Unit typology - Residenal - unidireconal
e) Type of drive - single speed drive
f) Type of Heat Recovery System - absent
g) Thermal eciency of heat recovery % N/A
h) Maximum ow rate m3/h 151
i) Electric power input at maximum ow rate W 16,3
j) Sound power level (L
WA
) dBA 49
k) Reference ow rate m3/s 151
l) Reference pressure dierence Pa 10
m) SEC warm climates W/m3/h 0,107
n1) Control factor - 0,65
n2) Control typology - Local demand control
o1) Maximum internal leakage rate % N/A
o2) Maximum external leakage rate % N/A
p1) Internal mixing rate % N/A
p2) External mixing rate % N/A
q) Visual lter warning - N/A
r) Instrucons to install regulated grilles - check the instrucon booklet
s) Internet address for preassembly/disassembly instrucons -
www.eltafans.com
t) Airow sensivity to pressure variaons
EN
13141 - 8
S3
u) Indoor/outdoor air ghtness
EN
13141 - 8
D2
v1) AEC - Annual electricity consumpon - warm climates kWh 0,9
v2) AEC - Annual electricity consumpon - average climates kWh 0,9
v3) AEC - Annual electricity consumpon - cold climates kWh 0,9
w1) AHS - Annual heang saved - warm climates kWh 11,8
w2) AHS - Annual heang saved - average climates kWh 26,2
w3) AHS - Annual heang saved - cold climates kWh 51,3
ErP Directive - Regulations 1253/2014 1254/2014