Optimus IA-20SIP User manual

Type
User manual

Optimus IA-20SIP is a compact and versatile IP SIP audio interface that enables bidirectional communication over IP networks. It features multiple connectivity options, including Ethernet and analog inputs and outputs, making it suitable for various applications such as public address systems, intercom systems, and remote monitoring. With its intuitive web-based configuration interface, the IA-20SIP is easy to set up and manage. Additionally, the device's rugged construction and support for Power over Ethernet (PoE) ensure reliable operation in demanding environments.

Optimus IA-20SIP is a compact and versatile IP SIP audio interface that enables bidirectional communication over IP networks. It features multiple connectivity options, including Ethernet and analog inputs and outputs, making it suitable for various applications such as public address systems, intercom systems, and remote monitoring. With its intuitive web-based configuration interface, the IA-20SIP is easy to set up and manage. Additionally, the device's rugged construction and support for Power over Ethernet (PoE) ensure reliable operation in demanding environments.

GUÍA RÁPIDA
IA-20SIP Versión 1.3 1/2
IA-20SIP
A
TENCI
Ó
N:
Antes de conectar el equipo asegúrese que la tensión
de suministro sea la adecuada.
No exponga el equipo a fuentes de calor.
La instalación debe ser realizada por personal técnico
cualificado.
INTERFAZ AUDIO IP SIP
ESPECIFICACIONES
Alimentación POE / 5 Vcc
Consumo 10 W Máx.
Dimensiones 214 x 105 x 41 mm
Peso 0,8 kg
Acabado Hierro pintado negro RAL9005
Accesorios
(no incluidos)
Z-112 Kit montaje en rack 1 unidad
Z-113 Kit montaje en rack 2 unidades
1. Contacto de salida por relé. Se cerrará a masa al recibir un tono DTMF previamente programado. Máx 24 V, 2 A.
2. Contacto de Salida PRI. Colector abierto. Se activará siempre que una llamada esté activa.
3. Salida Audio Nivel Micro -60 dB.
4. Salida Audio Nivel Aux 0 dB.
5. Salida audio 8 Ohm 2 W.
6. Entrada alimentación 5 Vcc.
7. Entrada de audio Micro/Aux y contacto de activación de llamada. Al cerrar el contacto a masa se realizará la llamada (por pulso o
nivel según configuración).
8. Selector Micro Aux. Seleccione ON, ON para Micro, o OFF, OFF para Aux.
9. Conector Ethernet POE.
10. Led Power. Indicador de alimentación.
11. Led Calling. Parpadeará durante el establecimiento de llamada, quedará fijo durante la llamada.
12. Led audio out. Indicador de nivel de audio de salida.
GUÍA RÁPIDA
IA-20SIP Versión 1.3 2/2
EJEMPLOS DE CONEXIÓN
INTERFAZ AUDIO IP SIP
CONFIGURACIÓN
CONFIGURACIÓN INTERNA
El equipo dispone de tres modos de funcionamiento EMISOR, RECEPTOR, y BIDIRECCIONAL. La configuración se realiza mediante jumpers
internos. El contacto de activación de llamada se activa por pulso en modo BIDIRECCIONAL y por nivel en modo EMISOR.
J1: Deshabilita salida
J2: Control
J3: Control
J4: Habilita entrada
*En modo Emisor el equipo receptor debe configurarse con descuelgue automático.* *Configuración de fábrica.
CONFIGURACIÓN VÍA SERVIDOR WEB
Los parámetros del equipo: IP, extensión, volumen... se configuran desde su servidor web. Para más detalle consulte el manual “Optimus SIP web
server configuration”.
(http://www.optimusaudio.com/arxius/i_tecnica/Optimus%20SIP%20web%20Server%20configuration%20ENG%20V1.1.pdf
).
Para el correcto funcionamiento del equipo deben configurase los LED de la siguiente manera:
Status Light LED1: Lit -> call successful, Blink -> call in progress
Status Light LED2: Lit -> call successful, Blink -> none
Comunicación unidireccional, IA-20SIP como emisor o receptor. En IA-20SIP emisor, contacto de activación de llamada activado por nivel.
Comunicación bidireccional, IA-20SIP como emisor y receptor. Contacto de activación de llamada activado por pulso en cualquiera de los
equipos.
JUMPER J1 J2 J3 J4
EMISOR* ON ON -> ON
RECEPTOR** OFF ON -> OFF
BIDIRECCIONAL OFF OFF <- ON
QUICK GUIDE
IA-20SIP Version 1.3 1/2
IA-20SIP
A
TTENTION:
Make sure the power source conforms to the power
requirements before connecting the equipment.
Do not install the unit near heat sources.
Only qualified service personnel should be allowed to
install and operate the unit.
IP SIP AUDIO INTERFACE
SPECIFICATIONS
Power supply POE / 5 Vcc
Consumption 10 W Máx.
Dimensions 214 x 105 x 41 mm
Weight 0,8 kg
Finish Black painted iron RAL9005
Accessories
(not included)
Z-112 Rack mounting kit for 1 unit
Z-113 Rack mounting kit for 2 units
1. Relay output contact. The contact is activated when it receives a DTMF tone previously programmed. Max 24 V, 2 A.
2. PRI output contact. Open collector. It remains activated while call is active.
3. Microphone Audio Output -60 dB.
4. Aux Audio Output 0 dB.
5. Speaker audio output 8 Ohm 2 W.
6. Power supply input 5 Vdc.
7. Micro/Aux audio input and call activation contact. When the Contact is closed equipment starts a call (by pulse or level according
to the configuration).
8. Micro/Aux switch. Select ON, ON for Microphone, or OFF, OFF for Aux.
9. Ethernet POE connector.
10. Power indicator Led.
11. Calling Led. It will blink during call establishment and it remains lit when cal is successful.
12. Audio output Led. Audio output level indicator.
QUICK GUIDE
IA-20SIP Version 1.3 2/2
CONNECTION EXAMPLES
IP SIP AUDIO INTERFACE
CONFIGURATION
INTERNAL CONFIGURATION
Three working modes are available; EMITTER, RECEIVER and BIDIRECTIONAL. The configuration is done by internal jumpers.
Call activation contact is activated by pulse in BIDIRECTIONAL MODE, and by level in EMITTER mode.
J1: Disables the output
J2: Control
J3: Control
J4: Enables the input.
*In EMITTER mode the receiver equipment must be set as automatic answer. **Factory default.
WEBSERVER CONFIGURATION
The device parameters: IP, extension, volume... are configured from unit’s Web Server. For more detail refer to "Optimus SIP web server
configuration" instruction manual.
(http://www.optimusaudio.com/arxius/i_tecnica/Optimus%20SIP%20web%20Server%20configuration%20ENG%20V1.1.pdf
).
For a proper operation of the device, you need to configure the LEDs as follow:
Status Light LED1: Lit -> call successful, Blink -> call in progress
Status Light LED2: Lit -> call successful, Blink -> none
Unidirectional communication, IA-20SIP as emitter or receiver. Call activation contact is activated by level in emitter IA-20SIP.
Bidirectional Communication, IA-20SIP as emitter and receiver. Call activation contact is activated by pulse in any of two equipments.
JUMPER J1 J2 J3 J4
EMITTER* ON ON -> ON
RECEIVER** OFF ON -> OFF
BIDIRECTIONAL OFF OFF <- ON
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Optimus IA-20SIP User manual

Type
User manual

Optimus IA-20SIP is a compact and versatile IP SIP audio interface that enables bidirectional communication over IP networks. It features multiple connectivity options, including Ethernet and analog inputs and outputs, making it suitable for various applications such as public address systems, intercom systems, and remote monitoring. With its intuitive web-based configuration interface, the IA-20SIP is easy to set up and manage. Additionally, the device's rugged construction and support for Power over Ethernet (PoE) ensure reliable operation in demanding environments.