QUICK GUIDE
EP-42SIPH Version 1.2 1/1
EP-42SIPH
WARNING:
Make sure the power outlet conforms to the power
requirements before connecting the equipment.
Do not install the unit near heat sources.
Only qualified service personnel should be allowed to
install and operate the unit.
SIP AUDIO STATION
SPECIFICATIONS AND CONNECTIONS
Power Source POE / 5 Vdc
Consumption 10 W Max
Dimensions 186 x 123 x 40 mm
Weight 1,1 kg
Finish Stainless Steel
Output Contact
CT1 Max 24 V, 2 A
CT1 +5o 5 V 200 mA
CT2 NO-C Max 24 V, 1 A
Protection IP-65 Equivalent (with optional box)
Optional Accessories
Wall mounting box CS-EP
Flush mounting box CE-EP
CONFIGURATION
Device parameters: IP, extension, volume... are configured from unit’s embedded Web Server. Recommended browsers are Firefox and Chrome. For more detail refer to "Optimus
SIP web server configuration” instruction manual.
Device’s IP can be found in a label in the rear panel. Using Windows7 or higher it is possible to discover the equipment automatically from the file browser by selecting the Network
icon. Is it necessary the have IPV6 and Network discovery enabled. You can also find it by typing its IPv6 address directly into the internet browser. It follows the typology
"[fe80::1a39:19ff:fexx:xxxx]" being the "x" the last six characters of the MAC address. (Login: admin, Password: admin)
Equipment has two output contacts. CT1 is used as door release contact, and it is activated during the call by dialling a configurable DTMF tone. CT2 is a status contact, for its
configuration set the equipment as follow:
- CT2 closed during the call. Configure “Status Light LED2: Lit” Call successful.
- CT2 closed during call establishment. Configure “Status Light LED2: Lit” Call in progress.
It includes a pre-recorded reassurance message for blind people, which is played during call establishment: "call in progress".
1. Speaker
2. Call button with LED indicator
3. Microphone