Connection-Wire Diagram
Installation
Brown
~Input
Blue Red
Output
Load
sensor
As shown by wiring connected to the power product.
Installation attention
Test
1.The light-control knob to adjust the maximum
(daytime), the time adjustment knob to the minimum;
2. And about 30s later turned into the working state,
the lamp, the hand in front of the sensor probe
window in the induction by shaking sensor signal,
the light from the light immediately, in the absence of
sustained induction under 7s ± 2s or so off;
3. Light-control knob to the minimum (night), lights
off, the hand in front of the sensor probe window
shaking, light does not shine. Opaque object (such
as cloth) cover the detection window, induction time,
lights, signals in the absence of induction lamp
under 7s ± 2s off as normal.
Notice: The lens cover can be poked up and down.
You can poke it downside to see the knob and
adjust accordingly.
Light-control knob
(adjustable)
Time setting knob
(adjustable)
1. In sense range there should not be isolation;
2. You should not install the unit facing window and where temperature change quickly (like air conditioning,
stove) to avoid working;
3. In front of sense window there should not be moving object, like hanging fan.etc.
4. If you unfamiliar with electricity, suggest electrician or experiencing human install the unit.
1The blue brown and red in diagram are
the blue wirebrown wire and red wire from
sensor;
2Connect the blue and brown with power;
3Connect the blue and red with load.
Troublesome
1. load do not work, please check:
whether the connection of power and load is correct or not;
whether the load is good or not;
whether the working light you set accord with ambient light or not.
2. Sensitivity is low, please check:
whether in front of sense window there is isolation to affect sensor receiving signal or not;
whether ambient temperature is too high or not;
whether sense signal source is in sense range or not;
3. Sensor can not shut off load, please check:
whether there is continual sensing signal in sense range or not;
Whether power accord with specification required or not;
Whether temperature near sensor changes quickly, for example: air conditioning, heater, etc.